123580 Wall Plug Dimmer

This describes the Z-Wave device 123580, manufactured by Popp & Co with the thing type UID of popp_123580_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

123580 product image

The 123580 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This is a wall plug dimmer that can be placed between a schuko wall outlet and electric devices, plugged in by cord. It can dim all incandescent lights, high voltage halogen lamps and transformers operated low voltage lamps without any restriction. Special optimization functions support the dimming of the majority of dimmable LED lights and Compact Fluorescent Lights (CFLs). The device is IP20 rated and can therefore only be used in dry environments. The device offers a Baby-Dim Function which dims down a lamp from a defined level into another defined level in a longer but also definable period (e.g. 20 minutes). An automatic Light-Off function and programmable dimming and switching behavior makes the device a very flexible tool for inhouse lighting.

Inclusion Information

 Inclusion and Exclusion are confirmed by a tripple click of the button. 

Exclusion Information

 Inclusion and Exclusion are confirmed by a tripple click of the button. 

Channels

The following table summarises the channels available for the 123580 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 17 configuration parameters available in the 123580. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set LED indication mode
2 Automatic switch off time If not zero, automatically switch off after a user defined time (in seconds)
3 RF Off command RF Off command
4 Ignore start level
5 Speed for fast dimming Speed for fast dimming
6 Speed for slow dimming Speed for slow dimming
7 Behavior when ON received Behavior when ON received
8 Baby dimming time Baby dimming time
9 Baby target light level Baby target level
10 Baby target time level Baby target level
17 Limit minimum light level Minimum level should be greater than maximum.
18 Limit maximum light level Maximum level should be greater than minimum. Set to 0 to act as a switch.
19 Dim Level on 'Switch On' Dim Level on 'Switch On'
51 Pause before pulse Pause before pulse
52 Pause after pulse Pause after pulse
53 Pulse width Pulse width
54 Pulse type NB: Do not touch these settings if you are not sure what they mean!
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 On when switch on
2 On when switch off
3 Operated by command

The manufacturer defined default value is 1 (On when switch on).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatic switch off time

If not zero, automatically switch off after a user defined time (in seconds)

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: RF Off command

RF Off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function:

  • Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics;
  • Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). The following option values may be configured -:
Value Description
0 Switch OFF
1 Ignore
2 Switch ON
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Ignore start level

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 1 (Yes).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Speed for fast dimming

Speed for fast dimming Time to dim on button presses and Set command (if it has no duration specified).

If not 0, dimming will be done smoothly to preserve bulb life.

Set in 10ms steps. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Speed for slow dimming

Speed for slow dimming Time to dim on button presses and Set command (if it has no duration specified).

If not 0, dimming will be done smoothly to preserve bulb life.

Set in 10ms steps. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Behavior when ON received

Behavior when ON received Defines the dim level on command 'ON'. On default he dimmer restores last dim level.

This parameter allows configuring the maximum level on second On command (if already On) or to always switch on to maximum level. The following option values may be configured -:

Value Description
0 Set to last dim level
1 If on already, set to maximum
2 Always maximum dim level

The manufacturer defined default value is 0 (Set to last dim level).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Baby dimming time

Baby dimming time Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action.

If enabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Baby target light level

Baby target level Target percentage level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Baby target time level

Baby target level Typical time used to differentiate click, hold, double and triple clicks.

Set in 10ms steps. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 17: Limit minimum light level

Minimum level should be greater than maximum.

Values in the range 1 to 95 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Limit maximum light level

Maximum level should be greater than minimum. Set to 0 to act as a switch.

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: Dim Level on 'Switch On'

Dim Level on 'Switch On' defines how the dimmer hall react on a simple ON Command.

Set to 0 to restore last level, otherwise sets dim level. Values in the range 0 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 51: Pause before pulse

Pause before pulse NB: Do not touch these settings if you are not sure what they mean!

For dimmable LEDs and CFL with bypass use value 1.

For other bulbs use default value.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 60 may be set.

The manufacturer defined default value is 28.

This parameter has the configuration ID config_51_1 and is of type INTEGER.

Parameter 52: Pause after pulse

Pause after pulse NB: Do not touch these settings if you are not sure what they mean!

For dimmable LEDs and CFL with bypass use value 40.

For other bulbs use default value.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 60 may be set.

The manufacturer defined default value is 28.

This parameter has the configuration ID config_52_1 and is of type INTEGER.

Parameter 53: Pulse width

Pulse width NB: Do not touch these settings if you are not sure what they mean!

For dimmable LEDs and CFL with bypass use value 20.

For other bulbs use default value.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 3 to 20 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_53_1 and is of type INTEGER.

Parameter 54: Pulse type

NB: Do not touch these settings if you are not sure what they mean! **NB: Do not touch these settings if you are not sure what they mean!**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Long
1 Short

The manufacturer defined default value is 0 (Long).

This parameter has the configuration ID config_54_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 123580 supports 1 association group.

Group 1: Switch State

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.