layout | title |
---|---|
documentation |
123580 - ZWave |
{% include base.html %}
This describes the Z-Wave device 123580, manufactured by Popp & Co with the thing type UID of popp_123580_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The 123580 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This is a wall plug dimmer that can be placed between a schuko wall outlet and electric devices, plugged in by cord. It can dim all incandescent lights, high voltage halogen lamps and transformers operated low voltage lamps without any restriction. Special optimization functions support the dimming of the majority of dimmable LED lights and Compact Fluorescent Lights (CFLs). The device is IP20 rated and can therefore only be used in dry environments. The device offers a Baby-Dim Function which dims down a lamp from a defined level into another defined level in a longer but also definable period (e.g. 20 minutes). An automatic Light-Off function and programmable dimming and switching behavior makes the device a very flexible tool for inhouse lighting.
Inclusion and Exclusion are confirmed by a tripple click of the button.
Inclusion and Exclusion are confirmed by a tripple click of the button.
The following table summarises the channels available for the 123580 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 17 configuration parameters available in the 123580. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Set LED indication mode | |
2 | Automatic switch off time | If not zero, automatically switch off after a user defined time (in seconds) |
3 | RF Off command | RF Off command |
4 | Ignore start level | |
5 | Speed for fast dimming | Speed for fast dimming |
6 | Speed for slow dimming | Speed for slow dimming |
7 | Behavior when ON received | Behavior when ON received |
8 | Baby dimming time | Baby dimming time |
9 | Baby target light level | Baby target level |
10 | Baby target time level | Baby target level |
17 | Limit minimum light level | Minimum level should be greater than maximum. |
18 | Limit maximum light level | Maximum level should be greater than minimum. Set to 0 to act as a switch. |
19 | Dim Level on 'Switch On' | Dim Level on 'Switch On' |
51 | Pause before pulse | Pause before pulse |
52 | Pause after pulse | Pause after pulse |
53 | Pulse width | Pulse width |
54 | Pulse type | NB: Do not touch these settings if you are not sure what they mean! |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | On when switch on |
2 | On when switch off |
3 | Operated by command |
The manufacturer defined default value is 1
(On when switch on).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
If not zero, automatically switch off after a user defined time (in seconds)
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
RF Off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function:
- Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics;
- Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Switch OFF |
1 | Ignore |
2 | Switch ON |
3 | Switch on if load is off else switch off |
The manufacturer defined default value is 0
(Switch OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 1
(Yes).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Speed for fast dimming Time to dim on button presses and Set command (if it has no duration specified).
If not 0, dimming will be done smoothly to preserve bulb life.
Set in 10ms steps. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Speed for slow dimming Time to dim on button presses and Set command (if it has no duration specified).
If not 0, dimming will be done smoothly to preserve bulb life.
Set in 10ms steps. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Behavior when ON received Defines the dim level on command 'ON'. On default he dimmer restores last dim level.
This parameter allows configuring the maximum level on second On command (if already On) or to always switch on to maximum level. The following option values may be configured -:
Value | Description |
---|---|
0 | Set to last dim level |
1 | If on already, set to maximum |
2 | Always maximum dim level |
The manufacturer defined default value is 0
(Set to last dim level).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Baby dimming time Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action.
If enabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Baby target level Target percentage level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Baby target level Typical time used to differentiate click, hold, double and triple clicks.
Set in 10ms steps. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Minimum level should be greater than maximum.
Values in the range 1 to 95 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Maximum level should be greater than minimum. Set to 0 to act as a switch.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Dim Level on 'Switch On' defines how the dimmer hall react on a simple ON Command.
Set to 0 to restore last level, otherwise sets dim level. Values in the range 0 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Pause before pulse NB: Do not touch these settings if you are not sure what they mean!
For dimmable LEDs and CFL with bypass use value 1.
For other bulbs use default value.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 60 may be set.
The manufacturer defined default value is 28
.
This parameter has the configuration ID config_51_1
and is of type INTEGER
.
Pause after pulse NB: Do not touch these settings if you are not sure what they mean!
For dimmable LEDs and CFL with bypass use value 40.
For other bulbs use default value.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 60 may be set.
The manufacturer defined default value is 28
.
This parameter has the configuration ID config_52_1
and is of type INTEGER
.
Pulse width NB: Do not touch these settings if you are not sure what they mean!
For dimmable LEDs and CFL with bypass use value 20.
For other bulbs use default value.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 3 to 20 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_53_1
and is of type INTEGER
.
NB: Do not touch these settings if you are not sure what they mean! **NB: Do not touch these settings if you are not sure what they mean!**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Long |
1 | Short |
The manufacturer defined default value is 0
(Long).
This parameter has the configuration ID config_54_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 123580 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.