Motion Sensor IN - ZWave

{% include base.html %}

Motion Sensor IN Motion Sensor IN

This describes the Z-Wave device Motion Sensor IN, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_motionsensorin_00_000.

The device is in the category of Sensor, defining Device used to measure something.

Motion Sensor IN product image

The Motion Sensor IN supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The Motion Sensor IN does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Motion Sensor with illuminance feature.

Inclusion Information

  1. Remove the sensor cover.
  2. Make sure the sensor is powered.
  3. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
  4. Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times..

Exclusion Information

  1. Remove the device cover.
  2. Make sure the sensor is powered.
  3. Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
  4. Press the button three times within 1.5 second, the device will enter exclusion mode.

Wakeup Information

The Motion Sensor IN does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time. The minimum wakeup interval is 300s, the maximum wakeup interval is 16,777,200s (about 194 days). Allowable interval among each wakeup interval is 60 second, such as 360, 420, 480…
Note: The default value is 12 hours. This value is longer, the battery life is greater.

Channels

The following table summarises the channels available for the Motion Sensor IN -:

Channel Name Channel ID Channel Type Category Item Type
Binary Sensor sensor_binary sensor_binary Switch
Sensor (luminance) sensor_luminance sensor_luminance Number
Alarm (general) alarm_general alarm_general Alarm Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Battery Level battery-level system.battery_level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel is of type sensor_luminance and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Alarm (general)

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 11 configuration parameters available in the Motion Sensor IN. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Sensitivity Level Setting Defines the sensitivity of PIR sensor.
2 ON/OFF Duration Setting Determined how long the associated devices should stay ON status
3 Basic Set Level Basic Set Command will be sent when the door/window is opened or closed
4 Enable/Disable PIR Function
5 Lux Level Set Set a lux level value which determines when the light sensor is activated.
6 Re-trigger Interval Adjust the interval of PIR being re-triggered
7 Light Sensor Polling Interval The Intervall after which the Light Sensor Measure is polled.
8 Lux Level Function Enable 0 = Off, 1 =On
9 Lux Level Changed Report How much the Lux Level must change
10 LED Blink Enable Defines whether the LED blinking is on / off
99 Ambient light intensity calibration Define the calibrated scale for ambient light intensity
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 1: Sensitivity Level Setting

Defines the sensitivity of PIR sensor.  Where 8 = highest & 255 = lowest sensitivity Values in the range 8 to 255 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: ON/OFF Duration Setting

Determined how long the associated devices should stay ON status For instance, this parameter is set to 30(second), the PIR detector will send a BASIC SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off. This Parameter value must be large than Parameter #6. Values in the range 5 to 600 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Basic Set Level

Basic Set Command will be sent when the door/window is opened or closed The receiver will take in for consideration; for instance, if a lamp module received the BSC of which value is decisive as to how bright of dim level of lamp module shall be.

Available Settings:

  • 0 - Off, Alarm cancelling or turning a device OFF
  • 1~99 or 255 – ON (Binary Switch Device)
  • Dim Level (Multilevel Switch Device) Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Enable/Disable PIR Function

The following option values may be configured -:

Value Description
0 Disable PIR Detector Function
255 Enable PIR Detector Function

The manufacturer defined default value is 255 (Enable PIR Detector Function).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Lux Level Set

Set a lux level value which determines when the light sensor is activated. If the ambient illumination level falls below this value and a person moves across or within the detected area , PIR detector will send a Z-Wave ON command(i.e. BASIC_SET value = parameter 3#) to an associated device and activate it. Values in the range 0 to 1000 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Re-trigger Interval

Adjust the interval of PIR being re-triggered No report will be sent during this interval if a movement is presented. This Parameter value must be less than Parameter 2#. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Light Sensor Polling Interval

The Intervall after which the Light Sensor Measure is polled.

Values in the range 60 to 36000 may be set.

The manufacturer defined default value is 180.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Lux Level Function Enable

0 = Off, 1 =On If this parameter is set to ‘1’, and when Lux level less than the value define by parameter #5, PIR detector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it. If Lux Level greater than the value define by parameter #5, PIR detector will not send a BASIC_SET command frame. The following option values may be configured -:

Value Description
0 Disable Lux Level Function
1 Enable Lux Level Function

The manufacturer defined default value is 0 (Disable Lux Level Function).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Lux Level Changed Report

How much the Lux Level must change How much the Lux Level must change, in lux, to be reported to the main controller. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: LED Blink Enable

Defines whether the LED blinking is on / off  1 = enable -> blink once when motion sensor detect movement,  0= disabled The following option values may be configured -:

Value Description
0 Disable LED blinking
1 Enable LED blinking

The manufacturer defined default value is 1 (Enable LED blinking).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 99: Ambient light intensity calibration

Define the calibrated scale for ambient light intensity  This parameter defines the calibrated scale for ambient light intensity, to allow more or less granular light measurements Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 1000.

This parameter has the configuration ID config_99_2 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Motion Sensor IN supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Is assigned to the device status - OPEN/CLOSED. It enables the sensor to send reports and readings to Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered.

  • NOTIFICATION_REPORT
  • COMMAND_CLASS_SENSOR_BINARY_V2
  • COMMAND_CLASS_SENSOR_MULTILEVEL_V7
  • BATTERY_REPORT
  • DEVICE_RESET_LOCALLY_NOTIFICATION

Association group 1 supports 1 node.

Group 2: Group 2

Sending Control Command to associated devices. This association group is configured through the advanced parameters no. 2, 3, 5 and 8 BASIC_SET

Association group 2 supports 4 nodes.

Group 3: Group 3

Send Notification to associated devices. NOTIFICATION_REPORT_V4

Association group 3 supports 4 nodes.

Group 4: Group 4

Send Notification to associated devices. SENSOR_BINARY_REPORT_V2

Association group 4 supports 4 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2