{% include base.html %}

L 810 LED iHF Sensor-switched outdoor up and downlighting

This describes the Z-Wave device L 810 LED iHF, manufactured by Steinel with the thing type UID of steinel_l810ledihf_00_000.

The device is in the category of Light Bulb, defining Devices that illuminate something, such as bulbs, etc..

L 810 LED iHF product image

The L 810 LED iHF supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

A high-quality product is cleverly thought through and made from materials that last. Its value also extends beyond today, it has permanency and constancy. The L 810 iHF outdoor SensorLight is an LED uplight and downlight that translates intelligent technology into form and function. For the first time, we have managed to make a light's sensor completely invisible – without compromising on first-class design and technological perfection. For stunning upward and downward lighting. New: optional manual override for 4 hours.

The optional Smart Friends box and the free Smart Friends app make it easy to set the L 810 LED iHF Z-Wave via smart phone or tablet. The light can also be switched ON or OFF via app. Other Steinel products can also be interconnected. If you wish, this also works via remote control when you are out. That completes your own light management system.

Inclusion Information

  1. Briefly press the device's button to set the light to inclusion mode.

Exclusion Information

Briefly press the device's button to set the light to exclusion mode. 

Channels

The following table summarises the channels available for the L 810 LED iHF -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Binary Sensor sensor_binary sensor_binary Switch
Sensor (luminance) sensor_luminance sensor_luminance Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (system) alarm_system alarm_system Switch
Dimmer 1 switch_dimmer1 switch_dimmer DimmableLight Dimmer
Scene Number 1 scene_number1 scene_number Number
Alarm (burglar) 2 alarm_burglar2 alarm_burglar Door Switch

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel is of type sensor_luminance and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number 1

Triggers when a scene button is pressed.

The scene_number1 channel is of type scene_number and supports the Number item.

Alarm (burglar) 2

Indicates if the burglar alarm is triggered.

The alarm_burglar2 channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 15 configuration parameters available in the L 810 LED iHF. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Time Duration of light after motion detection.
2 Light Light threshold [lx]:
3 Dim Night dim mode and time [min]: (only for SLAMP with DIM ability)
4 Range Motion Radar Range [cm]: (only for iHF sensor)
5 Sensity Motion Radar Sensitivity [%]: (SLAMP+SPIR)
6 Brighntes Meas Interval Brightness measuring interval [min]: (only SLAMP)
8 Global_Light Use external Ambient Light value:
9 Slave_Mode Disable local control:
10 Off_Behaviour Off behaviour (timeout):
11 On_Behaviour On behaviour (timeout):
12 On_Time_Over On behaviour time over (timeout):
13 On_Off_Behaviour Sequence On-Off behaviour (timeout):
14 Off_On_Behaviour Sequence Off-On behaviour (timeout):
15 Sequence_Time Sequence timing:
16 Motion_Disable Motion Off behaviour (timeout):
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Time

Duration of light after motion detection.

Values in the range 5 to 900 may be set.

The manufacturer defined default value is 180.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Light

Light threshold [lx]: 0 – run Learn ambient light sequence. 2000 – is used as daylight (always night mode). Value can be controlled via potentiometer (if present on device) – potentiometer value is then used as the default value and any potentiometer movement rewrites the current setting. Values in the range 2 to 2000 may be set.

The manufacturer defined default value is 2000.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Dim

Night dim mode and time [min]: (only for SLAMP with DIM ability) 0 – off (dim = basic light completely disabled). 1-60 – time [minutes] (enabled in night mode, starts after lamp is switched off after motion detection). -1 – whole night (dim through the whole night when lamp is off). Dim mode is also disabled when local control is disabled as well as in Slave mode. Values in the range 0 to 60 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Range

Motion Radar Range [cm]: (only for iHF sensor) Value can be controlled via potentiometer (if present on device) – potentiometer value is then used as default value and any potentiometer movement rewrites the current setting. Values in the range 100 to 500 may be set.

The manufacturer defined default value is 500.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Sensity

Motion Radar Sensitivity [%]: (SLAMP+SPIR) Value can be controlled via potentiometer (if present on device) – potentiometer value is then used as the default value and any potentiometer movement rewrites the current setting. Values in the range 2 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Brighntes Meas Interval

Brightness measuring interval [min]: (only SLAMP) Interval for measuring ambient light when lamp is on (lamp switches off briefly and measures). 0 = function is off. Values in the range 0 to 120 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 8: Global_Light

Use external Ambient Light value: When GLOBAL_LIGHT mode is ON – device overrides its own light sensor values and uses Light Report values from any Z-Wave light sensor instead – this has to be configured appropriately to send light automatically. If the last remote light level value is older than 30 minutes, the internal light value is used again until the next external value is received. Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Slave_Mode

Disable local control: Bit Field: bit 7 6 5 4 3 2 1 0 Function - Don’t use button for lamp switching (STOGGLE) - - - "Stupid" mode Central unit checking in slave mode  Slave mode

"Stupid" mode (bit 2 = 1):

  • has higher priority then slave mode - lamp/relay is permanently on (for simple power wall switch controlling)

Slave mode (bit 0 =1):

  • only if included in Z-Wave network
  • useful for controlling via third-party sensor - lamp/relay is directly controlled via Z-Wave, internal sensors are not used for controlling it

Central unit checking (bit 1 =1):

(useful especially for controlling via gateway)

When slave bit is 0:

  • device signalises fail of lifeline connection (if this bit is zero, fail of lifeline connection is not signalised)

When slave bit is 1:

  • device checks presence of Z-Wave device in lifeline group (gateway). If it is not present for 2 minutes (testing repeatedly every 30 seconds) device switches to normal mode in the same way as after the end of local disabled mode (ON_BEHAVIOUR)
  • the device checks every 1 minute for recovery of lifeline connection
  • if no lifeline specified
  • it works in normal mode

Do not use button for lamp switching (bit 6 = 1):

only for STOGGLE variant

  • disables button controlling device itself along with controlling group 5. When enabled also works in stand-alone.

Be careful with this option, device stops using its own motion sensor in Slave and "Stupid" mode. Values in the range 0 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Off_Behaviour

Off behaviour (timeout): Behaviour after BASIC OFF (and similar commands). If a transition (even with zero change) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case.

0 Lamp/Relay is switched off and remains so until any new motion event (local or remote) is received.

1 - 209 Lamp/Relay is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution

210 - 254 Reserved

255 Lamp/relay is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: On_Behaviour

On behaviour (timeout): Behaviour after BASIC ON (and similar commands). If a transition (even with zero change) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case.

0 Lamp/relay is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.

1 - 209 Lamp/relay is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.

210 - 254 Reserved

255 Lamp/relay is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: On_Time_Over

On behaviour time over (timeout): Time limit to stop waiting for motion after timeout of ON_BEHAVIOUR or OFF_ON_BEHAVIOUR (0-209) to prevent staying ON forever when there is no motion.

0 No additional waiting for motion.

1 - 209 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution

210 - 254 Reserved

255 Never stop waiting for motion. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 204.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: On_Off_Behaviour

Sequence On-Off behaviour (timeout): Behaviour after a rapid sequence of BASIC ON and BASIC OFF commands. The intention is to use a much longer timeout value than the time after a single ON command which should then be followed by a short timeout value. The behaviour is the same as for parameter 10 (OFF_LOCAL_DISABLE) except: 255 – device ignores ON - OFF sequence and uses OFF behaviour. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 204.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 14: Off_On_Behaviour

Sequence Off-On behaviour (timeout): Behaviour after a rapid sequence of BASIC OFF and BASIC ON commands. The intention is to use a much longer timeout value than the time after a single OFF command which should then be followed by a short timeout value. The behaviour is the same as for parameter 11 (ON_LOCAL_DISABLE) except: 255 – device ignores OFF - ON sequence and uses ON behaviour. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 204.

This parameter has the configuration ID config_14_2 and is of type INTEGER.

Parameter 15: Sequence_Time

Sequence timing: Time in [100 milliseconds] of maximum delay between BASIC ON and BASIC OFF (and vice versa) to consider this as a sequence. It is typically 1 second, but can be exceptionally longer due to retransmissions and overload – in this case, a longer interval can be allowed (up to 5 seconds). Values in the range 10 to 50 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Motion_Disable

Motion Off behaviour (timeout): Motion disable timeout after BASIC SET to motion endpoint when the internal motion sensor is not used for evaluating the behaviour of the lamp(SLAMP) relay(SPIR) and groups 2 and 3. Events are, however, still transmitted to the Lifeline, and the device can be controlled via remote motion sensors.

0 BASIC SET to motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, (SPIR) motion sensor still enabled

1 - 209 Internal motion sensor is disabled for specified timeout after BASIC SET 0x00 to motion endpoint. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution

210 - 254 Reserved

255 BASIC SET to motion endpoint ignored, motion sensor still disabled. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 209.

This parameter has the configuration ID config_16_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The L 810 LED iHF supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline Lifeline messages - Device Reset Locally (immediately) - Notifications: 0x09 (System) – Hardware failure with manufacturer proprietary code (0x03) 0x09 (System) – Software failure with manufacturer proprietary code (0x04) 0x07 (Home security) – Motion Begin event (0x08) 0x07 (Home security) – Motion End event (0x00, 0x08) - Binary Switch Report (SPIR) - Binary Switch Report (SBIN) - Multilevel Switch Report (SMUL) - Multilevel Sensor Report – value of internal ambient light sensor - Central scene notification (STOGGLE) Motion Begin and Motion End events are sent along with frames to group 3. If multichannel association is created the events are sent from motion sensor endpoint. Switch Report is sent immediately upon a change of status along with frames to group 2. If multichannel association is created the events are sent from lamp/relay endpoint. Multilevel Sensor Report is sent a maximum of once per 1 minute (if the value has changed by at least 3%) and a minimum of once per 15 minutes (if the value has not changed). If the ambient light value is old (cannot be measured because of permanent light), the value is not transmitted via lifeline. Multilevel Sensor Report can also be added to some other events to send in bulk. If multichannel association is created the events are sent from light sensor endpoint. Central scene notification is sent as reaction to user interaction. If multichannel association is created the events are sent from toggle button endpoint. All notifications to lifeline are sent as sensor states regardless of sensor settings and

Association group 1 supports 1 node.

Group 2: Control: Key01

On/Off control Group 2 is used for directly controlling Z-Wave devices via BASIC SET commands through the evaluation of movement and light, as with internal use (so that all of these devices work together). This is intended for use especially with third-party devices that do not implement reactions for motion events. BASIC_SET and similar Z-Wave commands are not retransmitted intentionally to slaves and must be sent to slave devices via the controlling device simultaneously. Only for use in master-slave system, multi-device control is not possible. Group 2 is evaluated and frames are transmitted there also in SLAVE_ MODE, regardless of LOCAL_DISABLED state and when MOTION_ENABLE is off (not using internal motion sensor, just reacting to remote motion events in this case). If multichannel association is created the events are sent from motion sensor endpoint.

Association group 2 supports 16 nodes.

Group 3: Notification: Motion

Motion Begin/End (PIR/radar/iHF) Group 3 sends MOTION_BEGIN and MOTION_END frames. MOTION_BEGIN frame = Notification 0x07 (Home security) – Motion detection without location (0x08) MOTION_END frame = Notification 0x07 (Home security) – Event inactive (0x00, parameter 0x08)After the first motion detection, MOTION_BEGIN is sent. If continual movement is detected, MOTION_BEGIN is sent every 1 minute repeatedly. When motion ends, MOTION_END is sent 5 seconds after the last motion detection. Notification to group 3 is sent only when NIGHT_MODE = ON and MOTION_ ENABLE = ON, regardless of LOCAL_DISABLE state. All devices in a group should have the same TIME settings in order that they switch off at the same time. If multichannel association is created the events are sent from motion sensor endpoint.

Association group 3 supports 16 nodes.

Group 4: Sensor: Luminescence

Ambient light Ambient Light via Group 4 is intended to substitute locally measured LUX values in target devices – so that the network can have one source of ambient light value. Frames are sent a maximum of once per 2.5 minutes and a minimum of once per 15 minutes. When device already uses remote Ambient Light value, then this value is also retransmitted to group 4. All devices in such a group should have the same LIGHT (threshold) settings in order that night mode is detected at the same time. If multichannel association is created the events are sent from light sensor endpoint.

Association group 4 supports 15 nodes.

Group 5: Control: Key02

On/Off button Group 5 is used for directly controlling Z-Wave devices via BASIC SET commands by button. (STOGGLE) If multichannel association is created the events are sent from toggle button endpoint.

Association group 5 supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V4
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V4 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V4 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.