This describes the Z-Wave device 0300/9499, manufactured by Technisat with the thing type UID of technisat_03009498_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The 0300/9499 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Single-Switch Relay controls the on/off function for one electrical device. It measures power consumption of the connected device. The single is installed in standard flush-mounted boxes.
- Install the TechniSat Shutter.
- After checking the correct installation, re-enable electrical power at the main fuse or circuit breaker.
- Start the Z-Wave device add mode on your Z-Wave gateway, according to the gateway‘s manual.
- Press T1 3x within 1 second.
- The red status LED is on while the device is added to the Z-Wave network.
- The green LED is on for 5 seconds after successfully adding the device.
Press and hold the upper position of the left button (T1) for at least 10 seconds when the shutter is in the top position.
The following table summarises the channels available for the 0300/9499 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Scene Number | scene_number | scene_number | Number | |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 6 configuration parameters available in the 0300/9499. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Central Scene notifications | Enable/Disable Central scene notifications for 2x-5x press |
2 | Current wattage meter | Interval of current wattage meter reports in 10 seconds |
3 | Active energy meter | Interval of active energy meter reports in minutes |
4 | Operation mode of button T | Change Operation mode of button T |
5 | Extension connector switch type | Configuration of switch type connected to extension connector S |
6 | Extension input scene mapping | Central Scene mapping of extension input S |
Enable/Disable Central scene notifications for 2x-5x press
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 1
(Enable).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Interval of current wattage meter reports in 10 seconds **** - disable unsolicited reports
3 ... 8640 (30 seconds - 1 day) Values in the range 0 to 8640 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Interval of active energy meter reports in minutes **** - disable unsolicited reports
10 ... 30240 (10 minutes - 3 weeks) Values in the range 0 to 30240 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Change Operation mode of button T **** - T1 turns output L1 on, T2 turn output L1 off
1 - T1 & T2 toggle output L1 The following option values may be configured -:
Value | Description |
---|---|
0 | T1 turns output L1 on, T2 turn output L1 off |
1 | T1 & T2 toggle output L1 |
The manufacturer defined default value is 0
(T1 turns output L1 on, T2 turn output L1 off).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Configuration of switch type connected to extension connector S **** - toggle switch
1 - push button switch The following option values may be configured -:
Value | Description |
---|---|
0 | toggle switch |
1 | push button switch |
The manufacturer defined default value is 0
(toggle switch).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Central Scene mapping of extension input S 1 - map S to central scene of T1
2 - map S to central scene of T2
3- map S to own central scene The following option values may be configured -:
Value | Description |
---|---|
1 | map S to central scene of T1 |
2 | map S to central scene of T2 |
3 | map S to own central scene |
The manufacturer defined default value is 1
(map S to central scene of T1).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 0300/9499 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
- Device Reset Locally Notification
- Central Scene notification
- Meter Report
- Switch Binary Report
- Notification Report
Association group 1 supports 1 node.
- Basic Set
Association group 2 supports 10 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |