{% include base.html %}

AZEMT500BB32MA American Standard Z-Wave Programmable Thermostat

This describes the Z-Wave device AZEMT500BB32MA, manufactured by Trane Corporation with the thing type UID of trane_azemt500bb32ma_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

AZEMT500BB32MA product image

The AZEMT500BB32MA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

T500B Z-Wave Thermostat. The ComfortLink™ control is an innovative product that is compatible with Trane products as well as any other brand of standard central heating and air conditioning systems. It works through the Nexia™ Home Intelligence system

Inclusion Information

Press the MENU button on the thermostat.
Scroll down to Z Wave Install, and press the Select button.
Press the Yes button to enroll the thermostat.

Exclusion Information

Press the MENU button on the thermostat.
Scroll down to Z-Wave Install and press the Select button.
Press the Yes button to exclude the thermostat.

Channels

The following table summarises the channels available for the AZEMT500BB32MA -:

Channel Name Channel ID Channel Type Category Item Type
Scene Number scene_number scene_number Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Clock Time Offset time_offset time_offset Time Number

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the AZEMT500BB32MA. Detailed information on each parameter can be found in the sections below.

Param Name Description
132 Schedule Mode

Parameter 132: Schedule Mode

The following option values may be configured -:

Value Description
0 Hold
1 Schedule

The manufacturer defined default value is 0 (Hold).

This parameter has the configuration ID config_132_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The AZEMT500BB32MA supports 1 association group.

Group 1: Reports

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links