NZW96 Outdoor Plug-in Module (1-Channel)

This describes the Z-Wave device NZW96, manufactured by Willis Electric Co., Ltd. with the thing type UID of willis_nzw96_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

NZW96 product image

The NZW96 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Inovelli's Outdoor Smart Plug-In On/Off Module + Repeater has the ability to turn on and off appliances, lights, and more from anywhere in the world. In addition to the outlet, the smart plug acts as a Z-Wave signal repeater, which amplifies your Z-Wave signal, growing the capabilities of your network.

Inclusion Information

Press the button on the front 5 times within 1 second.

Exclusion Information

Press the front button 5 times within 1 second.

Channels

The following table summarises the channels available for the NZW96 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm (heat) alarm_heat alarm_heat Fire Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel is of type alarm_heat and supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the NZW96. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Indicator Change the behavior of the LED Indicator
2 Countdown Plug Auto Shutoff
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED Indicator

Change the behavior of the LED Indicator

The following option values may be configured -:

Value Description
0 Plug On / LED On
1 Plug On / LED Off
2 LED Disabled

The manufacturer defined default value is 0 (Plug On / LED On).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Countdown

Plug Auto Shutoff

Values in the range 0 to 36000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The NZW96 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Send Baxic Set

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.