Skip to content

Latest commit

 

History

History
executable file
·
142 lines (95 loc) · 5.27 KB

sdm1100_0_0.md

File metadata and controls

executable file
·
142 lines (95 loc) · 5.27 KB
layout title
documentation
SD-M1100 - ZWave

{% include base.html %}

SD-M1100 Yale Smart Door Lock Z-Wave Module 2

This describes the Z-Wave device SD-M1100, manufactured by ASSA ABLOY with the thing type UID of yale_sdm1100_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

SD-M1100 product image

The SD-M1100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Smart Door Lock Z-Wave Module

Inclusion Information

Based on Remote Controller Add on user manual each Yale product.

This in steps for Yale Conexis L1

  1. Put the Z-Wave controller into add or learn mode
  2. Enter the master code on the lock, followed by #
  3. Press the 4 button, followed by #
  4. Press the 1 button followed by #
  5. Refer to the operation manual of the Z-Wave controller to complete the learn in proccess.

Exclusion Information

 Based on Remote Controller Remove on user manual each Yale product.

This in steps for Yale Conexis L1

  1. Put the Z-Wave controller into add or learn mode
  2. Enter the master code on the lock, followed by #
  3. Press the 4 button, followed by #
  4. Press the 3 button followed by #
  5. Refer to the operation manual of the Z-Wave controller to complete the learn in proccess.

Channels

The following table summarises the channels available for the SD-M1100 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm alarm_general alarm_general Alarm Switch
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SD-M1100 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_TIME_V1
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.