Skip to content

Latest commit

 

History

History
executable file
·
254 lines (165 loc) · 8.87 KB

yrd110_0_0.md

File metadata and controls

executable file
·
254 lines (165 loc) · 8.87 KB
layout title
documentation
YRD110 - ZWave

{% include base.html %}

YRD110 Yale button deadbolt without keyway

This describes the Z-Wave device YRD110, manufactured by ASSA ABLOY with the thing type UID of yale_yrd110_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

YRD110 product image

The YRD110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Security Keyless Push Button Stand Alone Deadbolt.

Inclusion Information

To enroll using the Z-Wave button:

  1. Remove the battery cover
  2. Press the Z-Wave button and hold until the lock beeps two times
  3. Release the button to start network joining
  4. Replace the battery conver

Exclusion Information

To remove the lock using the Z-Wave button:

  1. Remove the battery cover
  2. Press the Z-Wave button and hold until the lock beeps five times
  3. Release the button to start network removal
  4. Replace the battery cover

Channels

The following table summarises the channels available for the YRD110 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm (access) alarm_access alarm_access Door Switch
Alarm (power) alarm_power alarm_power Energy Switch
Alarm (raw) alarm_raw alarm_raw String
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Alarm (access)

Indicates if the access control alarm is triggered.

The alarm_access channel is of type alarm_access and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (raw)

Provides alarm parameters as json string.

The alarm_raw channel is of type alarm_raw and supports the String item. This is a read only channel so will only be updated following state changes from the device. This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the YRD110. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Volume Volume of beeps
2 Auto relock Auto relocking after unlocked
3 Auto relock time Time for auto relock
4 Wrong code limit Number of incorrect PINs before lockout
7 Shutdown time Incorrect attempts shutdown time
8 Operation Mode Operation Mode
Lock Timeout Sets the time after which the door will auto lock

Parameter 1: Volume

Volume of beeps

The following option values may be configured -:

Value Description
1 Loud
3 Silent

The manufacturer defined default value is 1 (Loud).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Auto relock

Auto relocking after unlocked

The following option values may be configured -:

Value Description
0 No auto-relock
255 Auto relock

The manufacturer defined default value is 0 (No auto-relock).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Auto relock time

Time for auto relock Amount of seconds between the door is unlocked and when it automatically attempts to re-lock itself, when auto-relocking is enabled. Values in the range 5 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Wrong code limit

Number of incorrect PINs before lockout Number of incorrect PINs that can be keyed in before lock goes into temporary keypad lockout mode. Values in the range 1 to 7 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 7: Shutdown time

Incorrect attempts shutdown time Amount of time lock should ignore the keypad, if the number of incorrect PINs is exceeded.  (Can still be locked and unlocked by zwave while in shutdown.)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_7_1 and is of type INTEGER. This is a read only parameter.

Parameter 8: Operation Mode

Operation Mode This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Normal
1 vacation
2 privacy

The manufacturer defined default value is 0 (Normal).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The YRD110 supports 1 association group.

Group 1: Receive Alarms

Group that will receive alarm notices from the lock The lock supports 1 association group with 5 devices. Alarm Reports are sent out unsolicited to devices included in the association group.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_TIME_V1
COMMAND_CLASS_TIME_PARAMETERS_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.