layout | title |
---|---|
documentation |
YRD110 - ZWave |
{% include base.html %}
This describes the Z-Wave device YRD110, manufactured by ASSA ABLOY with the thing type UID of yale_yrd110_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Security Keyless Push Button Stand Alone Deadbolt.
To enroll using the Z-Wave button:
- Remove the battery cover
- Press the Z-Wave button and hold until the lock beeps two times
- Release the button to start network joining
- Replace the battery conver
To remove the lock using the Z-Wave button:
- Remove the battery cover
- Press the Z-Wave button and hold until the lock beeps five times
- Release the button to start network removal
- Replace the battery cover
The following table summarises the channels available for the YRD110 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (raw) | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if the access control alarm is triggered.
The alarm_access
channel is of type alarm_access
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 6 configuration parameters available in the YRD110. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Volume | Volume of beeps |
2 | Auto relock | Auto relocking after unlocked |
3 | Auto relock time | Time for auto relock |
4 | Wrong code limit | Number of incorrect PINs before lockout |
7 | Shutdown time | Incorrect attempts shutdown time |
8 | Operation Mode | Operation Mode |
Lock Timeout | Sets the time after which the door will auto lock |
Volume of beeps
The following option values may be configured -:
Value | Description |
---|---|
1 | Loud |
3 | Silent |
The manufacturer defined default value is 1
(Loud).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Auto relocking after unlocked
The following option values may be configured -:
Value | Description |
---|---|
0 | No auto-relock |
255 | Auto relock |
The manufacturer defined default value is 0
(No auto-relock).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Time for auto relock Amount of seconds between the door is unlocked and when it automatically attempts to re-lock itself, when auto-relocking is enabled. Values in the range 5 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Number of incorrect PINs before lockout Number of incorrect PINs that can be keyed in before lock goes into temporary keypad lockout mode. Values in the range 1 to 7 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Incorrect attempts shutdown time Amount of time lock should ignore the keypad, if the number of incorrect PINs is exceeded. (Can still be locked and unlocked by zwave while in shutdown.)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
This is a read only parameter.
Operation Mode This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | vacation |
2 | privacy |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD110 supports 1 association group.
Group that will receive alarm notices from the lock The lock supports 1 association group with 5 devices. Alarm Reports are sent out unsolicited to devices included in the association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.