I'm setting up alarm server in my hikvision NVR but I'm facing a problem:
Control Panel ask me several info. First of all the protocol (HIKVISION,OPTEX,GJD,Luminate) and depending of the protocol selected I have to specify username and password. I'm confused because I was expecting only address, port and nothing more. I'm using IOT channel Settings -> Alarm Device -> New device

I was trying to use HA interface to add the alarm device but i gave me an ISAPI ERROR so I'm trying to set it up by myself via hikvision web interface.

any Ideas ?
Thank You

@maciej-or
Copy link
Owner

I guess you tried set something different. See screenshots here #23
Keep in mind that not all devices / firmwares support that.
You can also share details of ISAPI ERROR as described here https://github.com/maciej-or/hikvision_next?tab=readme-ov-file#reporting-issues then I could help more.

@mvedana
Copy link
Author

mvedana commented Dec 31, 2023

Thank you fort your answer; the link was very useful. It took me some days to verify my configuration and I got the wrong point of my configuration. I'm going to report it to help anybody else with same issue:
There was two errors:
1: in my hikvision nvr configuration ( DS-7608NI-I2 / 8P) I had both input alarm and output alarm set up. ISAPI error disappears when I choose "Manual alarm" in Output alarm tab.
2: My Input alarm was misconfigured and has been configured with: N.C. (normally closed) and handling mode: Disabled

In my HA I was using the wrong value as automation input. the right event is "When XYX starts detecting motion" ( I was using "Motion activated" that is another kind of event).
The Alarm server in my NVR is located under : Network -> Advanced configuration -> Other