Need Code Example Read PZEM-004T V.30 from PLC Keyence KV7500+KVL21V #90
Comments
I am sorry, unfortunately, the library doesn't support the PLC platform at the moment and I am not sure it ever will. Have you considered using the ESP32 to read the values from the PZEM modules and forwarding them to the PLC? I don't know that communication protocols the PLC supports, but I am sure you can set up a UART/SPI/I2C/Wifi connection that will allow you to relay the data. |
Most PLCs from that generation will handle RS232 / RS485 but you'll have to understand the protocol and be able to parse data to whatever protocol you planning on using . If you have an HMI with WiFi capability then you may be able to send MQTT packages to it but this will depend on the manufacturer (Weintek). Good luck |
Thank you mandulaj for your reply, So now I know that the sensor doesn't support with PLC. But for the connection from sensor to PLC is through some devices, not directly connected : |
Thank you Nismonx for your reply, yes of course I have used the RS485 Communication Protocol (2 wire - half duplex) from PZEM Sensor to PLC, and I think it will work because the PZEM Sensor Datasheet mention it (Application Layer Protocol - Modbus RTU). But, unfortunately it doesn't work properly. |
I don't know what your PLC know-how is, but I found this [link] (https://www.keyence.com.sg/support/user/plc/) where you can find support and assistance. Sorry if I don't help you more, 15 devices are enough for me to open a ticket. |
So my alternative solution is, I haven't use the PLC for read the PZEM Sensor. I used the ESP32 for read the PZEM Sensor and send it to database |
Yes this Is a way but consider this as Plan B ( my opinion of course) |
Thank you Sergiocntr for your advice. I think enough for me to use and struggle read the PZEM Sensor with PLC's haha, because my deadline is near I have to done in October until the Data Processing. |
Of course, this is my Plan B. Thank you GBU |
Is your feature request related to a problem? Please describe.
I have ordinary use the PZEM sensor with microcontroller, but I have challenges to read the sensor with PLC Keyence, and I have stucked. Any one help me?
Describe the solution you'd like
I have 15 PZEM to read with ModBUS RTU Communication Protocol. I have done to change the slave address through ESP32, and I have try to read from PLC, but still can't
Thank you in advance