ifm3d - Troubleshooting Guide

You can use this guide to help you identify and resolve basic problems you may be experiencing with ifm3d library or ifm 3d cameras.

Select the troubleshooting options

Connecting the camera

While connecting to device through ifm3d e.g.

    $ ifm3d ls

if you get following error message

ifm3d error: -100001
Lib: XMLRPC Timeout - can you `ping' the sensor?

This shows that ifm3d is not able to connect to device on your network.

Following are some guidelines to troubleshoot this issue

Provide the device IP address to the ifm3d

ifm3d by default connects to the default IP <"192.168.0.69">, one can also pass the IP through enviornment variable IFM3D_IP and for command line tools through --ip switch. To get the application list from camera one can use following command

    $ ifm3d --ip=192.168.0.69 ls
    $ IFM3D_IP=192.168.0.69 ifm3d ls
Check if you can ping the camera

Power on the network and camera and check if you are able to ping the camera. If not successfull check for the physical connections.

If you are behind the proxy network

Ping to device might not be successful if you are under proxy network, to resolve this issue one needs to bypass the proxy for the device address. A quick fix is to set the environment variable no_proxy to the IP address of the device. If you are working with multiple devices it is always good to bypass the required IP's in ~/.bashrc file as shown below:

    $ vi ~/.bashrc
    no_proxy="127.0.0.1, localhost,  192.168.0.69, 192.168.0.70, 192.168.1.* "
DHCP enabled device on DHCP network

On Windows, use IVA ifm Vision Assistant software to search the device on the network and obtain the IP Address of device

On Linux,use following command

 $ avahi-browse -arp 2>/dev/null | grep  ^=.*O3D.*Workstation

ifm3d logging

This section will help you to understand the different log levels used in ifm3d

ifm3d log levels

ifm3d defines several severity levels in its logging subsystem. These are defined here. The primarily used log levels are IFM3D_TRACE and IFM3D_PROTO_DEBUG. The former is used for logging general flow control of the software at a verbosity level suitable for debugging general issues, while the latter helps debug issues associated with the wire protocol between this library and the hardware.

Increasing the log levels at runtime

When running the ifm3d command-line program or your own program which linked to an ifm3d shared library, the logging can be turned up to get more info. For example:

    $ IFM3D_VLOG=15 ifm3d config < foo.json

The log output can be found at /tmp/ifm3d.INFO There is a file for each log level INFO, WARNING, and ERROR.

Changing the log directory

You can also change the GLog log directory with following commad

    $ GLOG_log_dir=<user log dir path> ifm3d config < foo.json

For more help on GLOG visit Glog Document

ifm3d not found

This might occur if ifm3d is not installed properly.

Troubleshoot on Windows

Set the ifm3d executable path in the enviornment path of the system. This is explained very well here.

Troubleshoot on Linux

Use intruction at the https://github.com/lovepark/ifm3d#the-default-build to build and install the library on Linux.