diff --git a/CMakeLists.txt b/CMakeLists.txt index fc9213a0..0ad7d6e1 100644 --- a/CMakeLists.txt +++ b/CMakeLists.txt @@ -2,7 +2,7 @@ set(AGENT_VERSION_MAJOR 2) set(AGENT_VERSION_MINOR 4) set(AGENT_VERSION_PATCH 0) -set(AGENT_VERSION_BUILD 8) +set(AGENT_VERSION_BUILD 9) set(AGENT_VERSION_RC "") # This minimum version is to support Visual Studio 2019 and C++ feature checking and FetchContent diff --git a/schemas/MTConnectAssets_2.4.xsd b/schemas/MTConnectAssets_2.4.xsd new file mode 100644 index 00000000..3731ce5a --- /dev/null +++ b/schemas/MTConnectAssets_2.4.xsd @@ -0,0 +1,17033 @@ + + + + + + + + root entity of an {{term(MTConnectAssets Response Document)}} that + contains the {{term(Asset Information Model)}} of {{block(Asset)}} + types. ![MTConnectAssets](figures/MTConnectAssets.png + "MTConnectAssets"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectAssets)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + + + The maximum number of assets + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + root entity of an {{term(MTConnectAssets Response Document)}} that + contains the {{term(Asset Information Model)}} of {{block(Asset)}} + types. ![MTConnectAssets](figures/MTConnectAssets.png + "MTConnectAssets"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectAssets)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + {{block(Assets)}} groups one or more {{block(Asset)}} types. See + {{package(Asset Information Model)}} for more details. + + + + + + + + + A URI reference + + + + + + + + The description of an asset, can be free form text or elements + + + + + + + Any elements + + + + + + + + + {{block(Assets)}} groups one or more {{block(Asset)}} types. See + {{package(Asset Information Model)}} for more details. + + + + + + + + + + {{term(asset)}} that is used by the manufacturing process to perform + tasks. > Note 1 to entry: An {{term(Asset)}} relies upon an + {{term(Device)}} to provide {{termplural(observation)}} and information + about itself and the {{term(Device)}} revises the information to reflect + changes to the {{term(Asset)}} during their interaction. Examples of + {{termplural(Asset)}} are cutting tools, Part Information, Manufacturing + Processes, Fixtures, and Files. > Note 2 to entry: A singular + {{property(Asset::assetId)}} uniquely identifies an {{term(Asset)}} + throughout its lifecycle and is used to track and relate the + {{term(Asset)}} to other {{termplural(Device)}} and entities. > Note + 3 to entry: {{termplural(Asset)}} are temporally associated with a + device and can be removed from the device without damage or alteration + to its primary functions. + + + + + + The unique identifier of the asset + + + + + + + The time asset information was recorded + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + The asset has been marked as removed + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + {{term(asset)}} that is used by the manufacturing process to perform + tasks. > Note 1 to entry: An {{term(Asset)}} relies upon an + {{term(Device)}} to provide {{termplural(observation)}} and information + about itself and the {{term(Device)}} revises the information to reflect + changes to the {{term(Asset)}} during their interaction. Examples of + {{termplural(Asset)}} are cutting tools, Part Information, Manufacturing + Processes, Fixtures, and Files. > Note 2 to entry: A singular + {{property(Asset::assetId)}} uniquely identifies an {{term(Asset)}} + throughout its lifecycle and is used to track and relate the + {{term(Asset)}} to other {{termplural(Device)}} and entities. > Note + 3 to entry: {{termplural(Asset)}} are temporally associated with a + device and can be removed from the device without damage or alteration + to its primary functions. + + + + + + + The interval between adjacent sampleing of data + + + + + + + + The frequency a measurement is sampled + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + An idref to the component id + + + + + + + + An idref to the data item id + + + + + + + + The item's reference to the data item or specificatiton + + + + + + + + The name of a related component + + + + + + + + The id reference for the coordinate system associated with this data + item + + + + + + + + An discrete event + + + + + + + + The description of a data item, can be free form text or elements + + + + + + + Any elements + + + + + + + + + The minimum limit on the change in a value + + + + + + + + The measurement sampling type + + + + + + + An event represents a change in state occurs at a point in time. + Note: An event does not occur at predefined frequencies. + + + + + + + A sample is a data point for continuous data items, that is, the + value of a data item at a point in time. + + + + + + + The condition of the device + + + + + + + + + The multiplier for the native value. Conversion divides by this value + + + + + + + + Description + + + + + + + series of sampled data. The data is reported for a specified number + of samples and each sample is reported with a fixed period. + + + + + + + measured value of the sample data. If no + {{property(DataItem::representation)}} is specified for a data item, + the {{property(DataItem::representation)}} **MUST** be determined to + be `VALUE`. + + + + + + + reported value(s) are represented as a set of {{termplural(key-value + pair)}}. Each reported value in the {{term(data set)}} **MUST** have + a unique key. + + + + + + + **DEPRECATED** as {{property(DataItem::representation)}} type in + *MTConnect Version 1.5*. Replaced by the + {{property(DataItem::discrete)}}. + + + + + + + two dimensional set of {{termplural(key-value pair)}} where the + {{block(Entry)}} represents a row, and the value is a set of + {{term(key-value pair)}} {{block(Cell)}} elements. A {{term(table)}} + follows the same behavior as the {{term(data set)}} for change + tracking, clearing, and history. When an {{block(Entry)}} changes, + all {{block(Cell)}} elements update as a single unit following the + behavior of a {{term(data set)}}. > Note: It is best to use + {{block(Variable)}} if the {{block(Cell)}} entities represent + multiple semantic types. Each {{block(Entry)}} in the + {{term(table)}} **MUST** have a unique key. Each {{block(Cell)}} of + each {{block(Entry)}} in the {{term(table)}} **MUST** have a unique + key. See {{block(Representation)}} in {{package(Observation + Information Model)}}, for a description of {{block(Entry)}} and + {{block(Cell)}} elements. + + + + + + + + + The type of filter + + + + + + + new value **MUST NOT** be reported for a data item unless the + measured value has changed from the last reported value by at least + the delta given as the value of this element. The value of + {{block(Filter)}} **MUST** be an absolute value using the same units + as the reported data. + + + + + + + data reported for a data item is provided on a periodic basis. The + `PERIOD` for reporting data is defined in the value of the + {{block(Filter)}}. The value of {{block(Filter)}} **MUST** be an + absolute value reported in seconds representing the time between + reported samples of the value of the data item. + + + + + + + + + + + + + + information reported about a piece of equipment. + + + + + + + + + information reported about a piece of equipment. + + + + + + + identifies the {{block(Component)}}, {{block(DataItem)}}, or + {{block(Composition)}} from which a measured value originates. + + + + + + + {{termplural(organize)}} a set of expected values that can be + reported for a {{block(DataItem)}}. + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + starting value for a {{block(DataItem)}} as well as the value to be + set for the {{block(DataItem)}} after a reset event. + + + + + + + type of event that may cause a reset to occur. + + + + + + + defines the meaning of {{block(Entry)}} and {{block(Cell)}} entities + when the associated {{property(DataItem::representation)}} is either + `DATA_SET` or `TABLE`. + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + unique identifier for the power source. + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + The statistical operation on this data + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The units as expressed by the machine + + + + + + + The units as expressed by the machine + + + + + + + The category of the data item + + + + + + + Description + + + + + + + The coordinate system reference to a particular coordinate system + + + + + + + The optional composition identifier + + + + + + + Used as the default sample rate for waveforms + + + + + + + Description + + + + + + + The number of significant digits for this data item + + + + + + + Description + + + + + + + + A set of limits for a data item + + + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST + NOT** be used in conjunction with any other + {{block(Constraint)}} elements. + + + + + + + + + numeric lower constraint. + + + + + + + numeric upper constraint. + + + + + + + numeric target or expected value. + + + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + A starting point for a data item + + + + + + + + + + The value element + + + + + + + + + + The filter for the data item + + + + + + + + The type of filter, ABSOLUTE or PERCENT + + + + + + + + + + A native data source + + + + + + + + The optional data item within the source component that provides + the underlying data + + + + + + + The component that is collecting the data associated with this + data item + + + + + + + The optional composition identifier for the source of this data + item + + + + + + + + + + The DataItem Definition + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + + + + unique key + + + + + + + The type of measurement + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + + {{block(CellDefinitions)}} groups one or more {{block(CellDefinition)}} + entities. See {{sect(CellDefinition)}}. + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + + + + Organizes DataItemRelationship and SpecificationRelationship + + + + + + + + + + Description + + + + + + identifier of the maintenance activity. + + + + + + + A reference to the related DataItem id. + + + + + + + + Description + + + + + + + How the data items are related + + + + + + + A reference to a DataItem that associates the values with an + external entity + + + + + + + The referenced DataItem provides the id of the effective Coordinate + System + + + + + + + The referenced DataItem provides process limits. + + + + + + + The referenced DataItem provides the observed values. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + How the data items are related + + + + + + + The referenced DataItem provides process limits. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + + + + An events data + + + + + + + + The item's unique ID that references the data item id from probe + + + + + + + + An Condition code as defined by the component + + + + + + + + {{block(Streams)}} groups one or more {{block(DeviceStream)}} entities. + See {{package(Observation Information Model)}} for more detail. + + + + + + + Description + + + + + + + + + Description + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} + for the {{block(ComponentStream)}} model. > Note 1 to entry: In + the {{term(XML)}} representation, {{block(ComponentStream)}} + entities **MUST NOT** appear in the {{term(MTConnectDevices Response + Document)}}. > Note 2 to entry: In the {{term(XML)}} + representation, {{block(ComponentStream)}} entities **MUST** appear + only in the {{term(MTConnectStreams Response Document)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + The unque identifier for this device + + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} for + the {{block(ComponentStream)}} model. > Note 1 to entry: In the + {{term(XML)}} representation, {{block(ComponentStream)}} entities **MUST + NOT** appear in the {{term(MTConnectDevices Response Document)}}. > + Note 2 to entry: In the {{term(XML)}} representation, + {{block(ComponentStream)}} entities **MUST** appear only in the + {{term(MTConnectStreams Response Document)}}. + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. + See {{sect(Sample)}}. + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + Description + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + identifier of the maintenance activity. + + + + + + + The device manufacturer component name + + + + + + + Description + + + + + + + The unque identifier for this component + + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. See + {{sect(Sample)}}. + + + + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + + + + A collection of conditions + + + + + + + + + + The observation value for indeterminent data + + + + + + + Data is unavailable + + + + + + + + + + The events sequence number + + + + + + + The event subtype corresponding to the measurement subtype + + + + + + + The time the event occurred or recorded + + + + + + + identifier of the maintenance activity. + + + + + + + The unique identifier of the item being produced + + + + + + + The identifier of the sub-element this result is in reference to + + + + + + + + Integer event value + + + + + + + + Integer event value + + + + + + + + String event value + + + + + + + + DateTime String event value + + + + + + + + A list of axis names + + + + + + + + + + + + A list of axis for an event + + + + + + + + Common floating point event value + + + + + + + + Description + + + + + + + An optional indicator that the event or sample was reset + + + + + + + + Description + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted datetime event + + + + + + + + + + + + + + An unfaceted datetime event + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with a three tuple floating point value + + + + + + + + + + + + + + An event with a three tuple floating point value + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Controlled vocabulary for ActuatorState + + + + + + + {{block(Actuator)}} is operating. + + + + + + + {{block(Actuator)}} is not operating. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Controlled vocabulary for Availability + + + + + + + data source is active and capable of providing data. + + + + + + + data source is either inactive or not capable of providing data. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + Controlled vocabulary for AxisCoupling + + + + + + + axes are physically connected to each other and operate as a single + unit. + + + + + + + axes are not physically connected to each other but are operating + together in lockstep. + + + + + + + axis is the master of the {{block(CoupledAxes)}}. + + + + + + + axis is a slave to the {{block(CoupledAxes)}}. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for AxisInterlock + + + + + + + axis lockout function is activated, power has been removed from the + axis, and the axis is allowed to move freely. + + + + + + + axis lockout function has not been activated, the axis may be + powered, and the axis is capable of being controlled by another + component. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Controlled vocabulary for AxisState + + + + + + + axis is in its home position. + + + + + + + axis is in motion. + + + + + + + axis has been moved to a fixed position and is being maintained in + that position either electrically or mechanically. Action is + required to release the axis from this position. + + + + + + + axis is stopped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Controlled vocabulary for ChuckInterlock + + + + + + + chuck cannot be unclamped. + + + + + + + chuck can be unclamped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Controlled vocabulary for ChuckState + + + + + + + {{block(Chuck)}} is open to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Controlled vocabulary for ControllerMode + + + + + + + {{block(Controller)}} is configured to automatically execute a + program. + + + + + + + {{block(Controller)}} is not executing an active program. It is + capable of receiving instructions from an external source – + typically an operator. The {{block(Controller)}} executes operations + based on the instructions received from the external source. + + + + + + + operator can enter a series of operations for the + {{block(Controller)}} to perform. The {{block(Controller)}} will + execute this specific series of operations and then stop. + + + + + + + {{block(Controller)}} is operating in a mode that restricts the + active program from processing its next process step without + operator intervention. + + + + + + + {{block(Controller)}} is currently functioning as a programming + device and is not capable of executing an active program. + + + + + + + axes of the device are commanded to stop, but the spindle continues + to function. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Controlled vocabulary for ControllerModeOverride + + + + + + + {{block(ControllerModeOverride)}} is in the `ON` state and the mode + override is active. + + + + + + + {{block(ControllerModeOverride)}} is in the `OFF` state and the mode + override is inactive. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Controlled vocabulary for Direction + + + + + + + clockwise rotation using the right-hand rule. + + + + + + + counter-clockwise rotation using the right-hand rule. + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + Controlled vocabulary for DoorState + + + + + + + {{block(Door)}} is open to the point of a positive confirmation. + + + + + + + {{block(Door)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Door)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + Controlled vocabulary for EmergencyStop + + + + + + + emergency stop circuit is complete and the piece of equipment, + component, or composition is allowed to operate. + + + + + + + operation of the piece of equipment, component, or composition is + inhibited. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Controlled vocabulary for EndOfBar + + + + + + + {{block(EndOfBar)}} has been reached. + + + + + + + {{block(EndOfBar)}} has not been reached. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + Controlled vocabulary for EquipmentMode + + + + + + + equipment is functioning in the mode designated by the `subType`. + + + + + + + equipment is not functioning in the mode designated by the + `subType`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Controlled vocabulary for Execution + + + + + + + {{block(Component)}} is ready to execute instructions. It is + currently idle. + + + + + + + {{block(Component)}} is actively executing an instruction. + + + + + + + {{block(Component)}} suspends the execution of the program due to an + external signal. Action is required to resume execution. + + + + + + + motion of the active axes are commanded to stop at their current + position. + + + + + + + {{block(Component)}} program is not `READY` to execute. + + + + + + + command from the program has intentionally interrupted execution. + The {{block(Component)}} **MAY** have another state that indicates + if the execution is interrupted or the execution ignores the + interrupt instruction. + + + + + + + command from the program has intentionally interrupted execution. + Action is required to resume execution. + + + + + + + program completed execution. + + + + + + + {{block(Component)}} suspends execution while a secondary operation + executes. Execution resumes automatically once the secondary + operation completes. + + + + + + + program has been intentionally optionally stopped using an M01 or + similar code. **DEPRECATED** in *version 1.4* and replaced with + `OPTIONAL_STOP`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + Controlled vocabulary for FunctionalMode + + + + + + + {{block(Component)}} is currently producing product, ready to + produce product, or its current intended use is to be producing + product. + + + + + + + {{block(Component)}} is not currently producing product. It is being + prepared or modified to begin production of product. + + + + + + + {{block(Component)}} is not currently producing product. Typically, + it has completed the production of a product and is being modified + or returned to a neutral state such that it may then be prepared to + begin production of a different product. + + + + + + + {{block(Component)}} is not currently producing product. It is + currently being repaired, waiting to be repaired, or has not yet + been returned to a normal production status after maintenance has + been performed. + + + + + + + {{block(Component)}} is being used to prove-out a new process, + testing of equipment or processes, or any other active use that does + not result in the production of product. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + Controlled vocabulary for PartDetect + + + + + + + part or work piece is detected or is present. + + + + + + + part or work piece is not detected or is not present. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for PathMode + + + + + + + path is operating independently and without the influence of another + path. + + + + + + + path provides information or state values that influences the + operation of other {{block(DataItem)}} of similar type. + + + + + + + physical or logical parts which are not physically connected to each + other but are operating together. + + + + + + + axes associated with the path are mirroring the motion of the + `MASTER` path. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + Controlled vocabulary for PowerState + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is present and + active. + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is not present + or is disconnected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + Controlled vocabulary for PowerStatus + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Controlled vocabulary for ProgramEdit + + + + + + + {{block(Controller)}} is in the program edit mode. + + + + + + + {{block(Controller)}} is capable of entering the program edit mode + and no function is inhibiting a change to that mode. + + + + + + + {{block(Controller)}} is being inhibited by a function from entering + the program edit mode. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Controlled vocabulary for ProgramLocationType + + + + + + + managed by the controller. + + + + + + + not managed by the controller. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Controlled vocabulary for RotaryMode + + + + + + + axis is functioning as a spindle. + + + + + + + axis is configured to index. + + + + + + + position of the axis is being interpolated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Controlled vocabulary for SpindleInterlock + + + + + + + power has been removed and the spindle cannot be operated. + + + + + + + spindle has not been deactivated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + {{def(EventEnum::USER)}} + + + + + + + + + + {{def(EventEnum::USER)}} + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + Controlled vocabulary for WaitState + + + + + + + execution is waiting while the equipment is powering up and is not + currently available to begin producing parts or products. + + + + + + + execution is waiting while the equipment is powering down but has + not fully reached a stopped state. + + + + + + + execution is waiting while one or more discrete workpieces are being + loaded. + + + + + + + execution is waiting while one or more discrete workpieces are being + unloaded. + + + + + + + execution is waiting while a tool or tooling is being loaded. + + + + + + + execution is waiting while a tool or tooling is being unloaded. + + + + + + + execution is waiting while material is being loaded. + + + + + + + execution is waiting while material is being unloaded. + + + + + + + execution is waiting while another process is completed before the + execution can resume. + + + + + + + execution is waiting while the equipment is pausing but the piece of + equipment has not yet reached a fully paused state. + + + + + + + execution is waiting while the equipment is resuming the production + cycle but has not yet resumed execution. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Controlled vocabulary for PartStatus + + + + + + + part conforms to given requirements. + + + + + + + part does not conform to some given requirements. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Controlled vocabulary for ConnectionStatus + + + + + + + no connection at all. + + + + + + + {{term(agent)}} is waiting for a connection request from an + {{term(adapter)}}. + + + + + + + open connection. The normal state for the data transfer phase of the + connection. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Controlled vocabulary for PartProcessingState + + + + + + + part occurrence is not actively being processed, but the processing + has not ended. Processing requirements exist that have not yet been + fulfilled. This is the default entry state when the part occurrence + is originally received. In some cases, the part occurrence may + return to this state while it waits for additional processing to be + performed. + + + + + + + part occurrence is actively being processed. + + + + + + + part occurrence is no longer being processed. A general state when + the reason for termination is unknown. + + + + + + + part occurrence has completed processing successfully. + + + + + + + process has been stopped during the processing. The part occurrence + will require special treatment. + + + + + + + processing of the part occurrence has come to a premature end. + + + + + + + terminal state when the part occurrence has been removed from the + equipment by an external entity and it no longer exists at the + equipment. + + + + + + + part occurrence has been skipped for processing on the piece of + equipment. + + + + + + + part occurrence has been processed completely. However, the + processing may have a problem. + + + + + + + part occurrence is waiting for transit. + + + + + + + part occurrence is being transported to its destination. + + + + + + + part occurrence has been placed at its designated destination. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Controlled vocabulary for ProcessState + + + + + + + device is preparing to execute the process occurrence. + + + + + + + process occurrence is ready to be executed. + + + + + + + process occurrence is actively executing. + + + + + + + process occurrence is now finished. + + + + + + + process occurrence has been stopped and may be resumed. + + + + + + + process occurrence has come to a premature end and cannot be + resumed. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Controlled vocabulary for ValveState + + + + + + + {{block(ValveState)}} where flow is allowed and the aperture is + static. > Note: For a binary value, `OPEN` indicates the valve + has the maximum possible aperture. + + + + + + + valve is transitioning from a `CLOSED` state to an `OPEN` state. + + + + + + + {{block(ValveState)}} where flow is not possible, the aperture is + static, and the valve is completely shut. + + + + + + + valve is transitioning from an `OPEN` state to a `CLOSED` state. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + Controlled vocabulary for LockState + + + + + + + mechanism is engaged and preventing the associated + {{block(Component)}} from being opened or operated. + + + + + + + mechanism is disengaged and the associated {{block(Component)}} is + able to be opened or operated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Controlled vocabulary for OperatingMode + + + + + + + automatically execute instructions from a recipe or program. > + Note: Setpoint comes from a recipe. + + + + + + + execute instructions from an external agent or person. > Note 1 + to entry: Valve or switch is manipulated by an agent/person. > + Note 2 to entry: Direct control of the PID output. % of the range: A + user manually sets the % output, not the setpoint. + + + + + + + executes a single instruction from a recipe or program. > Note 1 + to entry: Setpoint is entered and fixed, but the PID is controlling. + > Note 2 to entry: Still goes through the PID control system. + > Note 3 to entry: Manual fixed entry from a recipe. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Controlled vocabulary for PartCountType + + + + + + + count is of individual items. + + + + + + + pre-specified group of items. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + Controlled vocabulary for LeakDetect + + + + + + + leak is currently being detected. + + + + + + + leak is currently not being detected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Controlled vocabulary for BatteryState + + + + + + + {{block(Component)}} is at it's maximum rated charge level. + + + + + + + {{block(Component)}}'s charge is increasing. + + + + + + + {{block(Component)}}'s charge is decreasing. + + + + + + + {{block(Component)}} is at it's minimum charge level. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Controlled vocabulary for CharacteristicStatus + + + + + + + measurement is within acceptable tolerances. + + + + + + + measurement is not within acceptable tolerances. + + + + + + + failed, but acceptable constraints achievable by utilizing + additional manufacturing processes. + + + + + + + measurement is indeterminate due to an equipment failure. + + + + + + + measurement cannot be determined. + + + + + + + measurement cannot be evaluated. + + + + + + + nominal provided without tolerance limits. {{cite(QIF 3:2018 + 5.10.2.6)}} + + + + + + + status of measurement cannot be determined. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Controlled vocabulary for UncertaintyType + + + + + + + {{term(combined standard uncertainty)}}. + + + + + + + {{term(standard uncertainty)}} using arithmetic mean or average the + observations. {{cite(JCGM 100:2008 4.2)}} + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Controlled vocabulary for InterfaceState + + + + + + + {{block(Interface)}} is currently operational and performing as + expected. + + + + + + + {{block(Interface)}} is currently not operational. + + + + + + + Value is indeterminate + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + The target rate a value can be sampled + + + + + + + + The number of items in the list + + + + + + + + Common floating point sample value + + + + + + + + Common floating point sample value + + + + + + + + Description + + + + + + + The rate the waveform was sampled at, default back to the value given + in the data item + + + + + + + An optional indicator that the event or sample was reset + + + + + + + The statistical operation on this data + + + + + + + The number of seconds since the reset of the statistic + + + + + + + + Description + + + + + + + A sample with a single floating point value + + + + + + + + + + + + + + A sample with a single floating point value + + + + + + + A sample with a three tuple floating point value + + + + + + + + + + + + + + A sample with a three tuple floating point value + + + + + + + The abstract waveform + + + + + + + + The number of samples + + + + + + + + + + The abstract waveform + + + + + + + Description + + + + + + + + + + + + + + Description + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Example + + + + + + + + + + Example + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Description + + + + + + + + + + Description + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + The description of the Condition + + + + + + + + The device's severity + + + + + + + + Identifier of an individual condition activation provided by a piece of + equipment + + + + + + + + A qualifier for the condition + + + + + + + The value is too high + + + + + + + The value is too low + + + + + + + + + Description + + + + + + + + + type of the power source. + + + + + + + The component specific Notifcation code + + + + + + + The component specific Notifcation code + + + + + + + An optional attribute that helps qualify the condition + + + + + + + The statistical operation on this data + + + + + + + + + + Description + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + + Identifier of an individual condition activation provided by a + piece of equipment + + + + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + The conditon can not be determined. + + + + + + + + + + The conditon can not be determined. + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + The tool location + + + + + + + + The number referenced in the program for this tool + + + + + + + + The number of times the cutter has been reconditioned + + + + + + + + The code for the connection to the machine + + + + + + + + The tool group associated with the tool + + + + + + + + A speed in RPM or mm/s + + + + + + + + + + A measurement value + + + + + + + + + + The number of location units required to hold this tool + + + + + + + + A measurement value + + + + + + + + The tool identifier + + + + + + + + The number of cutting edges + + + + + + + + The number of additional locations taken by a tool + + + + + + + + The life of the tool in time, wear, or parts + + + + + + + + An identifier for the insert + + + + + + + + A single or range of indexes. A range can be a comma separated set of + individual elements as in "1,2,3,4", or as a inclusive range + of values as in "1-10" or multiple ranges "1-4,6-10" + + + + + + + + + + A minimum value + + + + + + + + A maximum value + + + + + + + + A nominal value + + + + + + + + The material for a cutting item + + + + + + + + A maximum count value + + + + + + + + A application specific code + + + + + + + + A comman delimited list of manufactures + + + + + + + + A relationship + + + + + + + + The format of the definition + + + + + + + The definition will be provided in EXPRESS format + + + + + + + The definition will be provided in XML + + + + + + + The definition will be provided in uninterpreted TEXT + + + + + + + The definition will be provided in an unspecified format + + + + + + + + + The state of the tool. These can be combined to define the complete + cutting tool state + + + + + + + The tool is new + + + + + + + The cutting tool is available for use + + + + + + + The cutting tool is unavailable for use + + + + + + + The cutting tool is assigned to this proces + + + + + + + The cutting tool is NOT assigned to this device + + + + + + + The tool has been measured + + + + + + + An unregisterd state + + + + + + + The tool is being reconditioned + + + + + + + The tool is used + + + + + + + The tool is dead + + + + + + + The tool is currently out being reconditioned or sharpened + + + + + + + The tool is broken + + + + + + + The status of this cutter is undetermined + + + + + + + + + The direction of tool life count + + + + + + + The tool life counts up from the 0 to maximum + + + + + + + The tool life counts down from maximum to 0 + + + + + + + + + The direction of tool life count + + + + + + + The tool life measured in minutes + + + + + + + The tool life measured in parts made + + + + + + + Measurement of tool life in tool wear + + + + + + + + + The type of tool location + + + + + + + A location in a tool magazine. updated + + + + + + + A location in a turret, tool bar, or tool rack. updated + + + + + + + A location within a tool crib. updated + + + + + + + A location associated with a spindle + + + + + + + A location for a tool awaiting transfer from a tool magazine to + spindle or a turret + + + + + + + A location for a tool removed from a spindle or turret and awaiting + return to a tool magazine + + + + + + + A location for a tool awaiting transfer to a tool magazine or turret + from outside of the piece of equipment. + + + + + + + A location for a tool removed from a tool magazine or turret + awaiting transfer to a location outside of the piece of equipment. + + + + + + + A location for a tool that is no longer useable and is awaiting + removal from a tool magazine or turret. + + + + + + + A location associated with an end effector + + + + + + + + + detailed structure of the cutting tool which is static during its + lifecycle. {{cite(ISO 13399)}}. + + + + + + + Any elements + + + + + + + + identifies the expected representation of the enclosed data. + + + + + + + + {{block(Asset)}} that physically removes the material from the workpiece + by shear deformation. + + + + + + + + + See {{sect(Description)}}. + + + + + + + + + detailed structure of the cutting tool which is static + during its lifecycle. {{cite(ISO 13399)}}. + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine + tool, presetter) and statistical process control + applications. Life cycle data will not remain static, but + will change periodically when a tool is used or measured. + + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine tool, + presetter) and statistical process control applications. Life + cycle data will not remain static, but will change + periodically when a tool is used or measured. + + + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + The manufacturer of this asset + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + {{block(Asset)}} that physically removes the material from the workpiece + by shear deformation. + + + + + + + {{block(Asset)}} that describes the static cutting tool geometries and + nominal values as one would expect from a tool catalog. + + + + + + + + + See {{sect(Description)}}. + + + + + + + + + detailed structure of the cutting tool which is static + during its lifecycle. {{cite(ISO 13399)}}. + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine + tool, presetter) and statistical process control + applications. Life cycle data will not remain static, but + will change periodically when a tool is used or measured. + + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine tool, + presetter) and statistical process control applications. Life + cycle data will not remain static, but will change + periodically when a tool is used or measured. + + + + + + + + + identifier for a class of cutting tools. + + + + + + + + + + {{block(Asset)}} that describes the static cutting tool geometries and + nominal values as one would expect from a tool catalog. + + + + + + + A archetypical cutting tool life cycle definition + + + + + + + number of times the cutter has been reconditioned. + + + + + + + The life of the cutting tool assembly + + + + + + + tool group this tool is assigned in the part program. + + + + + + + number of the tool as referenced in the part program. + + + + + + + constrained process spindle speed for the tool in + revolutions/minute. The {{property(ProcessSpindleSpeed::value)}} + **MAY** contain the nominal process target spindle speed if + available. If {{block(ProcessSpindleSpeed)}} is provided, at least + one value of {{property(ProcessSpindleSpeed::maximum)}}, + {{property(ProcessSpindleSpeed::nominal)}}, or + {{property(ProcessSpindleSpeed::minimum)}} **MUST** be specified. + + + + + + + constrained process feed rate for the tool in mm/s. The + {{property(ProcessFeedRate::value)}} **MAY** contain the nominal + process target feed rate if available. If {{block(ProcessFeedRate)}} + is provided, at least one value of + {{property(ProcessFeedRate::maximum)}}, + {{property(ProcessFeedRate::nominal)}}, or + {{property(ProcessFeedRate::minimum)}} **MUST** be specified. + + + + + + + identifier for the capability to connect any component of the + cutting tool together, except Assembly Items, on the machine side. + Code: `CCMS` + + + + + + + Any additional properties + + + + + + + {{block(Measurements)}} groups one or more {{block(Measurement)}} + subtypes. See {{sect(Measurement)}}. + + + + + + + {{block(CuttingItems)}} groups one or more {{block(CuttingItem)}} + entities. See {{sect(CuttingItem)}} and {{package(Cutting Item)}} + for more detail. + + + + + + + + + data regarding the application or use of the tool. This data is provided + by various pieces of equipment (i.e. machine tool, presetter) and + statistical process control applications. Life cycle data will not + remain static, but will change periodically when a tool is used or + measured. + + + + + + + {{block(CutterStatus)}} provides the status of the assembly and + {{term(organize)}} one or more {{block(Status)}} entities. See + {{sect(Status)}}. The following combinations of {{block(Status)}} + entities **MUST NOT** occur for a {{block(CutterStatus)}}: * `NEW` + **MUST NOT** be used with `USED`, `RECONDITIONED`, or `EXPIRED`. * + `UNKNOWN` **MUST NOT** be used with any other status. * `ALLOCATED` + and `UNALLOCATED` **MUST NOT** be used together. * `AVAILABLE` and + `UNAVAILABLE` **MUST NOT** be used together. * If the tool is + `EXPIRED`, `BROKEN`, or `NOT_REGISTERED` it **MUST NOT** be + `AVAILABLE`. + + + + + + + number of times the cutter has been reconditioned. + + + + + + + Description + + + + + + + tool group this tool is assigned in the part program. + + + + + + + number of the tool as referenced in the part program. + + + + + + + Description + + + + + + + constrained process spindle speed for the tool in + revolutions/minute. The {{property(ProcessSpindleSpeed::value)}} + **MAY** contain the nominal process target spindle speed if + available. If {{block(ProcessSpindleSpeed)}} is provided, at least + one value of {{property(ProcessSpindleSpeed::maximum)}}, + {{property(ProcessSpindleSpeed::nominal)}}, or + {{property(ProcessSpindleSpeed::minimum)}} **MUST** be specified. + + + + + + + constrained process feed rate for the tool in mm/s. The + {{property(ProcessFeedRate::value)}} **MAY** contain the nominal + process target feed rate if available. If {{block(ProcessFeedRate)}} + is provided, at least one value of + {{property(ProcessFeedRate::maximum)}}, + {{property(ProcessFeedRate::nominal)}}, or + {{property(ProcessFeedRate::minimum)}} **MUST** be specified. + + + + + + + identifier for the capability to connect any component of the + cutting tool together, except Assembly Items, on the machine side. + Code: `CCMS` + + + + + + + Any additional properties + + + + + + + {{block(Measurements)}} groups one or more {{block(Measurement)}} + subtypes. See {{sect(Measurement)}}. + + + + + + + {{block(CuttingItems)}} groups one or more {{block(CuttingItem)}} + entities. See {{sect(CuttingItem)}} and {{package(Cutting Item)}} + for more detail. + + + + + + + + + reference information about the {{property(Asset::assetId)}} and/or the + URL of the data source of {{block(CuttingToolArchetype)}}. + + + + + + + + identifies the {{block(Component)}}, {{block(DataItem)}}, or + {{block(Composition)}} from which a measured value originates. + + + + + + + + + + {{block(CutterStatus)}} provides the status of the assembly and + {{term(organize)}} one or more {{block(Status)}} entities. See + {{sect(Status)}}. The following combinations of {{block(Status)}} + entities **MUST NOT** occur for a {{block(CutterStatus)}}: * `NEW` + **MUST NOT** be used with `USED`, `RECONDITIONED`, or `EXPIRED`. * + `UNKNOWN` **MUST NOT** be used with any other status. * `ALLOCATED` and + `UNALLOCATED` **MUST NOT** be used together. * `AVAILABLE` and + `UNAVAILABLE` **MUST NOT** be used together. * If the tool is `EXPIRED`, + `BROKEN`, or `NOT_REGISTERED` it **MUST NOT** be `AVAILABLE`. + + + + + + + status of the cutting tool. + + + + + + + + + Description + + + + + + + + The type of location + + + + + + + number of locations at lower index values from this location. + + + + + + + number of locations at higher index value from this location. + + + + + + + Description + + + + + + + Description + + + + + + + Description + + + + + + + The tool bar associated with a tool + + + + + + + Description + + + + + + + + + + number of times the cutter has been reconditioned. + + + + + + + + The maximum number of times this tool can be reconditioned + + + + + + + + + + constrained process spindle speed for the tool in revolutions/minute. + The {{property(ProcessSpindleSpeed::value)}} **MAY** contain the nominal + process target spindle speed if available. If + {{block(ProcessSpindleSpeed)}} is provided, at least one value of + {{property(ProcessSpindleSpeed::maximum)}}, + {{property(ProcessSpindleSpeed::nominal)}}, or + {{property(ProcessSpindleSpeed::minimum)}} **MUST** be specified. + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + constrained process feed rate for the tool in mm/s. The + {{property(ProcessFeedRate::value)}} **MAY** contain the nominal process + target feed rate if available. If {{block(ProcessFeedRate)}} is + provided, at least one value of {{property(ProcessFeedRate::maximum)}}, + {{property(ProcessFeedRate::nominal)}}, or + {{property(ProcessFeedRate::minimum)}} **MUST** be specified. + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + Description + + + + + + + + The number of significant digits + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The native units for the measurement, if different from units + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + Description + + + + + + + Measurements for both the assembly and the cutting item + + + + + + + + + + Measurements for both the assembly and the cutting item + + + + + + + Measurements for the assembly + + + + + + + + + + Measurements for the assembly + + + + + + + Measurements for the cutting item + + + + + + + + + + Measurements for the cutting item + + + + + + + A collection of assembly measurements + + + + + + + + + + + dimension from the yz-plane to the furthest point of the tool item or + adaptive item measured in the -X direction. + + + + + + + + + + dimension from the yz-plane to the furthest point of the tool item or + adaptive item measured in the -X direction. + + + + + + + total weight of the cutting tool in grams. The force exerted by the mass + of the cutting tool. + + + + + + + + + + total weight of the cutting tool in grams. The force exerted by the mass + of the cutting tool. + + + + + + + distance from the gauge plane or from the end of the shank to the + furthest point on the tool, if a gauge plane does not exist, to the + cutting reference point determined by the main function of the tool. The + {{block(CuttingTool)}} functional length will be the length of the + entire tool, not a single cutting item. Each {{block(CuttingItem)}} can + have an independent {{block(FunctionalLength)}} represented in its + measurements. + + + + + + + + + + distance from the gauge plane or from the end of the shank to the + furthest point on the tool, if a gauge plane does not exist, to the + cutting reference point determined by the main function of the tool. The + {{block(CuttingTool)}} functional length will be the length of the + entire tool, not a single cutting item. Each {{block(CuttingItem)}} can + have an independent {{block(FunctionalLength)}} represented in its + measurements. + + + + + + + largest diameter of the body of a tool item. + + + + + + + + + + largest diameter of the body of a tool item. + + + + + + + distance measured along the X axis from that point of the item closest + to the workpiece, including the cutting item for a tool item but + excluding a protruding locking mechanism for an adaptive item, to either + the front of the flange on a flanged body or the beginning of the + connection interface feature on the machine side for cylindrical or + prismatic shanks. + + + + + + + + + + distance measured along the X axis from that point of the item closest + to the workpiece, including the cutting item for a tool item but + excluding a protruding locking mechanism for an adaptive item, to either + the front of the flange on a flanged body or the beginning of the + connection interface feature on the machine side for cylindrical or + prismatic shanks. + + + + + + + maximum diameter of a circle on which the defined point Pk of each of + the master inserts is located on a tool item. The normal of the machined + peripheral surface points towards the axis of the cutting tool. + + + + + + + + + + maximum diameter of a circle on which the defined point Pk of each of + the master inserts is located on a tool item. The normal of the machined + peripheral surface points towards the axis of the cutting tool. + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + maximum engagement of the cutting edge or edges with the workpiece + measured perpendicular to the feed motion. + + + + + + + + + + maximum engagement of the cutting edge or edges with the workpiece + measured perpendicular to the feed motion. + + + + + + + largest length dimension of the cutting tool including the master insert + where applicable. + + + + + + + + + + largest length dimension of the cutting tool including the master insert + where applicable. + + + + + + + dimension of the diameter of a cylindrical portion of a tool item or an + adaptive item that can participate in a connection. + + + + + + + + + + dimension of the diameter of a cylindrical portion of a tool item or an + adaptive item that can participate in a connection. + + + + + + + dimension of the height of the shank. + + + + + + + + + + dimension of the height of the shank. + + + + + + + dimension of the length of the shank. + + + + + + + + + + dimension of the length of the shank. + + + + + + + maximum length of a cutting tool that can be used in a particular + cutting operation including the non-cutting portions of the tool. + + + + + + + + + + maximum length of a cutting tool that can be used in a particular + cutting operation including the non-cutting portions of the tool. + + + + + + + Abstract cutter life + + + + + + + + One of time, part count, or wear + + + + + + + The count up or count down + + + + + + + {{term(condition state)}} that requires concern and supervision + and may become hazardous if no action is taken. + + + + + + + Maximum tool life + + + + + + + The life when the tool is new + + + + + + + + + + A collection of assembly measurements + + + + + + + + + + + diameter of a circle on which the defined point Pk located on this + cutting tool. The normal of the machined peripheral surface points + towards the axis of the cutting tool. + + + + + + + + + + diameter of a circle on which the defined point Pk located on this + cutting tool. The normal of the machined peripheral surface points + towards the axis of the cutting tool. + + + + + + + nominal radius of a rounded corner measured in the X Y-plane. + + + + + + + + + + nominal radius of a rounded corner measured in the X Y-plane. + + + + + + + theoretical length of the cutting edge of a cutting item over sharp + corners. + + + + + + + + + + theoretical length of the cutting edge of a cutting item over sharp + corners. + + + + + + + distance from the basal plane of the tool item to the cutting point. + + + + + + + + + + distance from the basal plane of the tool item to the cutting point. + + + + + + + theoretical sharp point of the cutting tool from which the major + functional dimensions are taken. + + + + + + + + + + theoretical sharp point of the cutting tool from which the major + functional dimensions are taken. + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + distance between the cutting reference point and the rear backing + surface of a turning tool or the axis of a boring bar. + + + + + + + + + + distance between the cutting reference point and the rear backing + surface of a turning tool or the axis of a boring bar. + + + + + + + angle between the tool rake plane and a plane parallel to the xy-plane + measured in the tool cutting edge plane + + + + + + + + + + angle between the tool rake plane and a plane parallel to the xy-plane + measured in the tool cutting edge plane + + + + + + + diameter of a circle to which all edges of a equilateral and round + regular insert are tangential. + + + + + + + + + + diameter of a circle to which all edges of a equilateral and round + regular insert are tangential. + + + + + + + angle between the major cutting edge and the same cutting edge rotated + by 180 degrees about the tool axis. + + + + + + + + + + angle between the major cutting edge and the same cutting edge rotated + by 180 degrees about the tool axis. + + + + + + + length of a portion of a stepped tool that is related to a corresponding + cutting diameter measured from the cutting reference point of that + cutting diameter to the point on the next cutting edge at which the + diameter starts to change. + + + + + + + + + + length of a portion of a stepped tool that is related to a corresponding + cutting diameter measured from the cutting reference point of that + cutting diameter to the point on the next cutting edge at which the + diameter starts to change. + + + + + + + angle between a major edge on a step of a stepped tool and the same + cutting edge rotated 180 degrees about its tool axis. + + + + + + + + + + angle between a major edge on a step of a stepped tool and the same + cutting edge rotated 180 degrees about its tool axis. + + + + + + + angle between the tool cutting edge plane and the tool feed plane + measured in a plane parallel the xy-plane. + + + + + + + + + + angle between the tool cutting edge plane and the tool feed plane + measured in a plane parallel the xy-plane. + + + + + + + angle between the tool cutting edge plane and a plane perpendicular to + the tool feed plane measured in a plane parallel the xy-plane. + + + + + + + + + + angle between the tool cutting edge plane and a plane perpendicular to + the tool feed plane measured in a plane parallel the xy-plane. + + + + + + + measure of the length of a wiper edge of a cutting item. + + + + + + + + + + measure of the length of a wiper edge of a cutting item. + + + + + + + angle of the tool with respect to the workpiece for a given process. The + value is application specific. + + + + + + + + + + angle between the driving mechanism locator on a tool item and the main + cutting edge. + + + + + + + + + + The location of the cutting item - not yet restricted. + + + + + + + + {{block(CuttingItems)}} groups one or more {{block(CuttingItem)}} + entities. See {{sect(CuttingItem)}} and {{package(Cutting Item)}} for + more detail. + + + + + + + part of of the tool that physically removes the material from the + workpiece by shear deformation. + + + + + + + + The number of edges + + + + + + + + part of of the tool that physically removes the material from the + workpiece by shear deformation. + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(CutterStatus)}} provides the status of the assembly and + {{term(organize)}} one or more {{block(Status)}} entities. See + {{sect(Status)}}. The following combinations of {{block(Status)}} + entities **MUST NOT** occur for a {{block(CutterStatus)}}: * `NEW` + **MUST NOT** be used with `USED`, `RECONDITIONED`, or `EXPIRED`. * + `UNKNOWN` **MUST NOT** be used with any other status. * `ALLOCATED` + and `UNALLOCATED` **MUST NOT** be used together. * `AVAILABLE` and + `UNAVAILABLE` **MUST NOT** be used together. * If the tool is + `EXPIRED`, `BROKEN`, or `NOT_REGISTERED` it **MUST NOT** be + `AVAILABLE`. + + + + + + + free form description of the location on the cutting tool. For + clarity, the words `FLUTE`, `INSERT`, and `CARTRIDGE` **SHOULD** be + used to assist in noting the location of a {{block(CuttingItem)}}. + {{property(CuttingItem::Locus)}} **MAY** be any free form string, + but **SHOULD** adhere to the following rules: * The location + numbering **SHOULD** start at the furthest {{block(CuttingItem)}} + and work it’s way back to the {{block(CuttingItem)}} closest to the + gauge line. * Flutes **SHOULD** be identified as such using the word + `FLUTE`:. For example: `FLUTE`: 1, `INSERT`: 2 - would indicate the + first flute and the second furthest insert from the end of the tool + on that flute. * Other designations such as `CARTRIDGE` **MAY** be + included, but should be identified using upper case and followed by + a colon (:). + + + + + + + life of a {{block(CuttingItem)}}. + + + + + + + tool group this tool is assigned in the part program. + + + + + + + Any additional properties + + + + + + + {{block(Measurements)}} groups one or more {{block(Measurement)}} + subtypes. See {{sect(Measurement)}}. + + + + + + + + The unique identifier of this insert in this assembly + + + + + + + The manufacturer identifier of this cutting item + + + + + + + The material used for the cutting item + + + + + + + The manufacturer of this asset + + + + + + + + The version of the file + + + + + + + + The mime type of the file + + + + + + + + The size in bytes of the file + + + + + + + + The name of the file + + + + + + + + Extended tyoe for The category of application that will use this file + + + + + + + + + + The category of application that will use this file + + + + + + + Files regarding the fully assembled product + + + + + + + Device related files + + + + + + + Files relating to the handling of material + + + + + + + File relating to equipment maintenance + + + + + + + Files relating to a part + + + + + + + Files related to the manufacturing process + + + + + + + Files related to the quality inspection + + + + + + + Files related to the setup of a process + + + + + + + + + The category of application that will use this file + + + + + + + + Extended tyoe for The type classification of a file + + + + + + + + + + The type classification of a file + + + + + + + Computer aided design files or drawings + + + + + + + Generic data + + + + + + + Documentation regarding a category of file + + + + + + + User instructions regarding the execution of a task + + + + + + + The data related to the history of a machine or process + + + + + + + Machine instructions to perform a process + + + + + + + + + The type classification of a file + + + + + + + + {{block(AbstractFile)}} type that provides information common to all + versions of a file. + + + + + + + + + {{block(FileProperties)}} groups one or more + {{block(FileProperty)}} entities for a {{block(File)}}. See + {{sect(FileProperty)}}. + + + + + + + {{block(FileComments)}} groups one or more + {{block(FileComment)}} entities for a {{block(File)}}. See + {{sect(FileComment)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + The mime type of the file + + + + + + + The classification of this file + + + + + + + The sub classification of this file + + + + + + + + + + {{block(AbstractFile)}} type that provides information common to all + versions of a file. + + + + + + + {{block(FileProperties)}} groups one or more {{block(FileProperty)}} + entities for a {{block(File)}}. See {{sect(FileProperty)}}. + + + + + + + key-value pair providing additional metadata about a + {{block(File)}}. + + + + + + + + + The value of a file property + + + + + + + + key-value pair providing additional metadata about a {{block(File)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + + + + File state + + + + + + + used for processes other than production or otherwise defined. + + + + + + + used for production processes + + + + + + + the content is modified from PRODUCTION or EXPERIMENTAL (Note: To + capture northbound changes. execution -> prod engineering) + + + + + + + + + An X501 Public Key + + + + + + + + A secure hash + + + + + + + + A file time + + + + + + + + {{block(AbstractFile)}} type that provides information about the + {{block(File)}} instance and its {{term(URL)}}. + + + + + + + + + {{block(FileProperties)}} groups one or more + {{block(FileProperty)}} entities for a {{block(File)}}. See + {{sect(FileProperty)}}. + + + + + + + {{block(FileComments)}} groups one or more + {{block(FileComment)}} entities for a {{block(File)}}. See + {{sect(FileComment)}}. + + + + + + + {{term(URL)}} reference to the file location. + + + + + + + secure hash of the file. + + + + + + + public key used to verify the signature. + + + + + + + {{block(Destinations)}} groups one or more + {{block(Destination)}} entities. See {{sect(Destination)}}. + + + + + + + time the file was created. + + + + + + + time the file was modified. + + + + + + + + identifier of the maintenance activity. + + + + + + + The mime type of the file + + + + + + + The classification of this file + + + + + + + The sub classification of this file + + + + + + + The size in bytes + + + + + + + The version identifier + + + + + + + The file state + + + + + + + + + + {{block(AbstractFile)}} type that provides information about the + {{block(File)}} instance and its {{term(URL)}}. + + + + + + + {{term(URL)}} reference to the file location. + + + + + + + + {{term(URL)}} giving the location of the image file. + + + + + + + Description + + + + + + + + + + Organizes file destinations + + + + + + + reference to the target {{block(Device)}} for this {{block(File)}}. + + + + + + + + + The Destination is a reference to the target Device for this File + + + + + + + + + + {{block(FileComments)}} groups one or more {{block(FileComment)}} + entities for a {{block(File)}}. See {{sect(FileComment)}}. + + + + + + + remark or interpretation for human interpretation associated with a + {{block(File)}} or {{block(FileArchetype)}}. + + + + + + + + + the text of the comment + + + + + + + + remark or interpretation for human interpretation associated with a + {{block(File)}} or {{block(FileArchetype)}}. + + + + + + + + The time the comment was made + + + + + + + + + + Extended tyoe for contained QIF Document type as defined in the QIF + Standard. + + + + + + + + + + contained QIF Document type as defined in the QIF Standard. + + + + + + + + + + + + + + + contained QIF Document type as defined in the QIF Standard. + + + + + + + + {{block(Asset)}} that carries the QIF Document. + + + + + + + + + + + + + + + The unique identifier for the material + + + + + + + + + + {{block(Asset)}} that carries the QIF Document. + + + + + + + + + + + + any element + + + + + + + + + The type of the material container. + + + + + + + + The serial number of the material container + + + + + + + + The ISO process type supported by this {{term(raw material)}} + + + + + + + + The type of material. + + + + + + + + The name of the raw feed stock manufacturer. + + + + + + + + The manufacturing date of the raw feed stock from the feed stock + manufacturer. + + + + + + + + The lot code of the raw feed stock from the feed stock manufacturer. + + + + + + + + The ASTM standard code that the material complies with. + + + + + + + + The lot code of the material contained within the material container. + + + + + + + + The form of the material in the material container. + + + + + + + + The date when the material container was first used. + + + + + + + + The date when the material container was last used. + + + + + + + + The amount of material initially placed in the material container when + manufactured. + + + + + + + + The dimension of material initially placed in the material container + when manufactured. + + + + + + + + The quantity of material initially placed in the material container when + manufactured. + + + + + + + + The quantity of material currently contained in the material container + + + + + + + + The dimension of material currently contained in the material container + + + + + + + + The quantity of material currently contained in the material container + + + + + + + + Extended tyoe for form of the {{term(raw material)}}. + + + + + + + + + + form of the {{term(raw material)}}. + + + + + + + + + + + + + + + + + + form of the {{term(raw material)}}. + + + + + + + + material used as the {{block(RawMaterial)}} + + + + + + + manufacturer's lot code of the material. + + + + + + + name of the material manufacturer. + + + + + + + manufacturing date of the material from the material manufacturer. + + + + + + + lot code of the raw feed stock for the material, from the feed stock + manufacturer. + + + + + + + {{term(ASTM)}} standard code that the material complies with. + + + + + + + + The unique identifier for the material + + + + + + + identifier of the maintenance activity. + + + + + + + The type of material. + + + + + + + + {{block(Asset)}} that represents {{term(raw material)}}. + + + + + + + + + form of the {{term(raw material)}}. + + + + + + + {{block(Material)}} has existing usable volume. + + + + + + + manufacturing date of the material from the material + manufacturer. + + + + + + + date {{term(raw material)}} was first used. + + + + + + + date {{term(raw material)}} was last used. + + + + + + + amount of material initially placed in {{term(raw material)}} + when manufactured. + + + + + + + dimension of material initially placed in {{term(raw material)}} + when manufactured. + + + + + + + quantity of material initially placed in {{term(raw material)}} + when manufactured. + + + + + + + amount of material currently in {{term(raw material)}}. + + + + + + + dimension of material currently in {{term(raw material)}}. + + + + + + + quantity of material currently in {{term(raw material)}}. + + + + + + + {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, + materials, or other types of goods. + + + + + + + + identifier of the maintenance activity. + + + + + + + The type of container holding the {{term(raw material)}}. + + + + + + + The ISO process type supported by this {{term(raw material)}}. + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + {{block(Asset)}} that represents {{term(raw material)}}. + + + + + + + property that determines the characteristic or behavior of an entity. + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST NOT** + be used in conjunction with any other {{block(Constraint)}} + elements. + + + + + + + + The identifier of the parameter + + + + + + + identifier of the maintenance activity. + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + {{block(Parameters)}} groups one or more {{block(Parameter)}} entities. + See {{sect(Parameter)}}. + + + + + + + property that determines the characteristic or behavior of an + entity. + + + + + + + + + set of {{block(Parameter)}}s. + + + + + + + {{block(Parameters)}} groups one or more {{block(Parameter)}} + entities. See {{sect(Parameter)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + + {{block(ParameterSets)}} groups one or more {{block(ParameterSet)}} + entities. See {{sect(ParameterSet)}}. + + + + + + + set of {{block(Parameter)}}s. + + + + + + + + + set of {{block(ParameterSet)}}s that govern the functionality of the + related {{block(Component)}}. + + + + + + + + + {{block(ParameterSets)}} groups one or more + {{block(ParameterSet)}} entities. See {{sect(ParameterSet)}}. + + + + + + + + + + + set of {{block(ParameterSet)}}s that govern the functionality of the + related {{block(Component)}}. + + + + \ No newline at end of file diff --git a/schemas/MTConnectAssets_2.4_1.0.xsd b/schemas/MTConnectAssets_2.4_1.0.xsd new file mode 100644 index 00000000..fe58e61b --- /dev/null +++ b/schemas/MTConnectAssets_2.4_1.0.xsd @@ -0,0 +1,17012 @@ + + + + + + + + root entity of an {{term(MTConnectAssets Response Document)}} that + contains the {{term(Asset Information Model)}} of {{block(Asset)}} + types. ![MTConnectAssets](figures/MTConnectAssets.png + "MTConnectAssets"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectAssets)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + + + The maximum number of assets + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + root entity of an {{term(MTConnectAssets Response Document)}} that + contains the {{term(Asset Information Model)}} of {{block(Asset)}} + types. ![MTConnectAssets](figures/MTConnectAssets.png + "MTConnectAssets"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectAssets)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + {{block(Assets)}} groups one or more {{block(Asset)}} types. See + {{package(Asset Information Model)}} for more details. + + + + + + + + + A URI reference + + + + + + + + The description of an asset, can be free form text or elements + + + + + + + Any elements + + + + + + + + + {{block(Assets)}} groups one or more {{block(Asset)}} types. See + {{package(Asset Information Model)}} for more details. + + + + + + + + + + {{term(asset)}} that is used by the manufacturing process to perform + tasks. > Note 1 to entry: An {{term(Asset)}} relies upon an + {{term(Device)}} to provide {{termplural(observation)}} and information + about itself and the {{term(Device)}} revises the information to reflect + changes to the {{term(Asset)}} during their interaction. Examples of + {{termplural(Asset)}} are cutting tools, Part Information, Manufacturing + Processes, Fixtures, and Files. > Note 2 to entry: A singular + {{property(Asset::assetId)}} uniquely identifies an {{term(Asset)}} + throughout its lifecycle and is used to track and relate the + {{term(Asset)}} to other {{termplural(Device)}} and entities. > Note + 3 to entry: {{termplural(Asset)}} are temporally associated with a + device and can be removed from the device without damage or alteration + to its primary functions. + + + + + + The unique identifier of the asset + + + + + + + The time asset information was recorded + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + The asset has been marked as removed + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + {{term(asset)}} that is used by the manufacturing process to perform + tasks. > Note 1 to entry: An {{term(Asset)}} relies upon an + {{term(Device)}} to provide {{termplural(observation)}} and information + about itself and the {{term(Device)}} revises the information to reflect + changes to the {{term(Asset)}} during their interaction. Examples of + {{termplural(Asset)}} are cutting tools, Part Information, Manufacturing + Processes, Fixtures, and Files. > Note 2 to entry: A singular + {{property(Asset::assetId)}} uniquely identifies an {{term(Asset)}} + throughout its lifecycle and is used to track and relate the + {{term(Asset)}} to other {{termplural(Device)}} and entities. > Note + 3 to entry: {{termplural(Asset)}} are temporally associated with a + device and can be removed from the device without damage or alteration + to its primary functions. + + + + + + + The interval between adjacent sampleing of data + + + + + + + + The frequency a measurement is sampled + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + An idref to the component id + + + + + + + + An idref to the data item id + + + + + + + + The item's reference to the data item or specificatiton + + + + + + + + The name of a related component + + + + + + + + The id reference for the coordinate system associated with this data + item + + + + + + + + An discrete event + + + + + + + + The description of a data item, can be free form text or elements + + + + + + + Any elements + + + + + + + + + The minimum limit on the change in a value + + + + + + + + The measurement sampling type + + + + + + + An event represents a change in state occurs at a point in time. + Note: An event does not occur at predefined frequencies. + + + + + + + A sample is a data point for continuous data items, that is, the + value of a data item at a point in time. + + + + + + + The condition of the device + + + + + + + + + The multiplier for the native value. Conversion divides by this value + + + + + + + + Description + + + + + + + series of sampled data. The data is reported for a specified number + of samples and each sample is reported with a fixed period. + + + + + + + measured value of the sample data. If no + {{property(DataItem::representation)}} is specified for a data item, + the {{property(DataItem::representation)}} **MUST** be determined to + be `VALUE`. + + + + + + + reported value(s) are represented as a set of {{termplural(key-value + pair)}}. Each reported value in the {{term(data set)}} **MUST** have + a unique key. + + + + + + + **DEPRECATED** as {{property(DataItem::representation)}} type in + *MTConnect Version 1.5*. Replaced by the + {{property(DataItem::discrete)}}. + + + + + + + two dimensional set of {{termplural(key-value pair)}} where the + {{block(Entry)}} represents a row, and the value is a set of + {{term(key-value pair)}} {{block(Cell)}} elements. A {{term(table)}} + follows the same behavior as the {{term(data set)}} for change + tracking, clearing, and history. When an {{block(Entry)}} changes, + all {{block(Cell)}} elements update as a single unit following the + behavior of a {{term(data set)}}. > Note: It is best to use + {{block(Variable)}} if the {{block(Cell)}} entities represent + multiple semantic types. Each {{block(Entry)}} in the + {{term(table)}} **MUST** have a unique key. Each {{block(Cell)}} of + each {{block(Entry)}} in the {{term(table)}} **MUST** have a unique + key. See {{block(Representation)}} in {{package(Observation + Information Model)}}, for a description of {{block(Entry)}} and + {{block(Cell)}} elements. + + + + + + + + + The type of filter + + + + + + + new value **MUST NOT** be reported for a data item unless the + measured value has changed from the last reported value by at least + the delta given as the value of this element. The value of + {{block(Filter)}} **MUST** be an absolute value using the same units + as the reported data. + + + + + + + data reported for a data item is provided on a periodic basis. The + `PERIOD` for reporting data is defined in the value of the + {{block(Filter)}}. The value of {{block(Filter)}} **MUST** be an + absolute value reported in seconds representing the time between + reported samples of the value of the data item. + + + + + + + + + + + + + + information reported about a piece of equipment. + + + + + + + + + information reported about a piece of equipment. + + + + + + + identifies the {{block(Component)}}, {{block(DataItem)}}, or + {{block(Composition)}} from which a measured value originates. + + + + + + + {{termplural(organize)}} a set of expected values that can be + reported for a {{block(DataItem)}}. + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + starting value for a {{block(DataItem)}} as well as the value to be + set for the {{block(DataItem)}} after a reset event. + + + + + + + type of event that may cause a reset to occur. + + + + + + + defines the meaning of {{block(Entry)}} and {{block(Cell)}} entities + when the associated {{property(DataItem::representation)}} is either + `DATA_SET` or `TABLE`. + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + unique identifier for the power source. + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + The statistical operation on this data + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The units as expressed by the machine + + + + + + + The units as expressed by the machine + + + + + + + The category of the data item + + + + + + + Description + + + + + + + The coordinate system reference to a particular coordinate system + + + + + + + The optional composition identifier + + + + + + + Used as the default sample rate for waveforms + + + + + + + Description + + + + + + + The number of significant digits for this data item + + + + + + + Description + + + + + + + + A set of limits for a data item + + + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST + NOT** be used in conjunction with any other + {{block(Constraint)}} elements. + + + + + + + + + numeric lower constraint. + + + + + + + numeric upper constraint. + + + + + + + numeric target or expected value. + + + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + A starting point for a data item + + + + + + + + + + The value element + + + + + + + + + + The filter for the data item + + + + + + + + The type of filter, ABSOLUTE or PERCENT + + + + + + + + + + A native data source + + + + + + + + The optional data item within the source component that provides + the underlying data + + + + + + + The component that is collecting the data associated with this + data item + + + + + + + The optional composition identifier for the source of this data + item + + + + + + + + + + The DataItem Definition + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + + + + unique key + + + + + + + The type of measurement + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + + {{block(CellDefinitions)}} groups one or more {{block(CellDefinition)}} + entities. See {{sect(CellDefinition)}}. + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + + + + Organizes DataItemRelationship and SpecificationRelationship + + + + + + + + + + Description + + + + + + identifier of the maintenance activity. + + + + + + + A reference to the related DataItem id. + + + + + + + + Description + + + + + + + How the data items are related + + + + + + + A reference to a DataItem that associates the values with an + external entity + + + + + + + The referenced DataItem provides the id of the effective Coordinate + System + + + + + + + The referenced DataItem provides process limits. + + + + + + + The referenced DataItem provides the observed values. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + How the data items are related + + + + + + + The referenced DataItem provides process limits. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + + + + An events data + + + + + + + + The item's unique ID that references the data item id from probe + + + + + + + + An Condition code as defined by the component + + + + + + + + {{block(Streams)}} groups one or more {{block(DeviceStream)}} entities. + See {{package(Observation Information Model)}} for more detail. + + + + + + + Description + + + + + + + + + Description + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} + for the {{block(ComponentStream)}} model. > Note 1 to entry: In + the {{term(XML)}} representation, {{block(ComponentStream)}} + entities **MUST NOT** appear in the {{term(MTConnectDevices Response + Document)}}. > Note 2 to entry: In the {{term(XML)}} + representation, {{block(ComponentStream)}} entities **MUST** appear + only in the {{term(MTConnectStreams Response Document)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + The unque identifier for this device + + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} for + the {{block(ComponentStream)}} model. > Note 1 to entry: In the + {{term(XML)}} representation, {{block(ComponentStream)}} entities **MUST + NOT** appear in the {{term(MTConnectDevices Response Document)}}. > + Note 2 to entry: In the {{term(XML)}} representation, + {{block(ComponentStream)}} entities **MUST** appear only in the + {{term(MTConnectStreams Response Document)}}. + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. + See {{sect(Sample)}}. + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + Description + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + identifier of the maintenance activity. + + + + + + + The device manufacturer component name + + + + + + + Description + + + + + + + The unque identifier for this component + + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. See + {{sect(Sample)}}. + + + + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + + + + A collection of conditions + + + + + + + + + + The observation value for indeterminent data + + + + + + + Data is unavailable + + + + + + + + + + The events sequence number + + + + + + + The event subtype corresponding to the measurement subtype + + + + + + + The time the event occurred or recorded + + + + + + + identifier of the maintenance activity. + + + + + + + The unique identifier of the item being produced + + + + + + + The identifier of the sub-element this result is in reference to + + + + + + + + Integer event value + + + + + + + + Integer event value + + + + + + + + String event value + + + + + + + + DateTime String event value + + + + + + + + A list of axis names + + + + + + + + + + + + A list of axis for an event + + + + + + + + Common floating point event value + + + + + + + + Description + + + + + + + An optional indicator that the event or sample was reset + + + + + + + + Description + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted datetime event + + + + + + + + + + + + + + An unfaceted datetime event + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with a three tuple floating point value + + + + + + + + + + + + + + An event with a three tuple floating point value + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Controlled vocabulary for ActuatorState + + + + + + + {{block(Actuator)}} is operating. + + + + + + + {{block(Actuator)}} is not operating. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Controlled vocabulary for Availability + + + + + + + data source is active and capable of providing data. + + + + + + + data source is either inactive or not capable of providing data. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + Controlled vocabulary for AxisCoupling + + + + + + + axes are physically connected to each other and operate as a single + unit. + + + + + + + axes are not physically connected to each other but are operating + together in lockstep. + + + + + + + axis is the master of the {{block(CoupledAxes)}}. + + + + + + + axis is a slave to the {{block(CoupledAxes)}}. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for AxisInterlock + + + + + + + axis lockout function is activated, power has been removed from the + axis, and the axis is allowed to move freely. + + + + + + + axis lockout function has not been activated, the axis may be + powered, and the axis is capable of being controlled by another + component. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Controlled vocabulary for AxisState + + + + + + + axis is in its home position. + + + + + + + axis is in motion. + + + + + + + axis has been moved to a fixed position and is being maintained in + that position either electrically or mechanically. Action is + required to release the axis from this position. + + + + + + + axis is stopped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Controlled vocabulary for ChuckInterlock + + + + + + + chuck cannot be unclamped. + + + + + + + chuck can be unclamped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Controlled vocabulary for ChuckState + + + + + + + {{block(Chuck)}} is open to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Controlled vocabulary for ControllerMode + + + + + + + {{block(Controller)}} is configured to automatically execute a + program. + + + + + + + {{block(Controller)}} is not executing an active program. It is + capable of receiving instructions from an external source – + typically an operator. The {{block(Controller)}} executes operations + based on the instructions received from the external source. + + + + + + + operator can enter a series of operations for the + {{block(Controller)}} to perform. The {{block(Controller)}} will + execute this specific series of operations and then stop. + + + + + + + {{block(Controller)}} is operating in a mode that restricts the + active program from processing its next process step without + operator intervention. + + + + + + + {{block(Controller)}} is currently functioning as a programming + device and is not capable of executing an active program. + + + + + + + axes of the device are commanded to stop, but the spindle continues + to function. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Controlled vocabulary for ControllerModeOverride + + + + + + + {{block(ControllerModeOverride)}} is in the `ON` state and the mode + override is active. + + + + + + + {{block(ControllerModeOverride)}} is in the `OFF` state and the mode + override is inactive. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Controlled vocabulary for Direction + + + + + + + clockwise rotation using the right-hand rule. + + + + + + + counter-clockwise rotation using the right-hand rule. + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + Controlled vocabulary for DoorState + + + + + + + {{block(Door)}} is open to the point of a positive confirmation. + + + + + + + {{block(Door)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Door)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + Controlled vocabulary for EmergencyStop + + + + + + + emergency stop circuit is complete and the piece of equipment, + component, or composition is allowed to operate. + + + + + + + operation of the piece of equipment, component, or composition is + inhibited. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Controlled vocabulary for EndOfBar + + + + + + + {{block(EndOfBar)}} has been reached. + + + + + + + {{block(EndOfBar)}} has not been reached. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + Controlled vocabulary for EquipmentMode + + + + + + + equipment is functioning in the mode designated by the `subType`. + + + + + + + equipment is not functioning in the mode designated by the + `subType`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Controlled vocabulary for Execution + + + + + + + {{block(Component)}} is ready to execute instructions. It is + currently idle. + + + + + + + {{block(Component)}} is actively executing an instruction. + + + + + + + {{block(Component)}} suspends the execution of the program due to an + external signal. Action is required to resume execution. + + + + + + + motion of the active axes are commanded to stop at their current + position. + + + + + + + {{block(Component)}} program is not `READY` to execute. + + + + + + + command from the program has intentionally interrupted execution. + The {{block(Component)}} **MAY** have another state that indicates + if the execution is interrupted or the execution ignores the + interrupt instruction. + + + + + + + command from the program has intentionally interrupted execution. + Action is required to resume execution. + + + + + + + program completed execution. + + + + + + + {{block(Component)}} suspends execution while a secondary operation + executes. Execution resumes automatically once the secondary + operation completes. + + + + + + + program has been intentionally optionally stopped using an M01 or + similar code. **DEPRECATED** in *version 1.4* and replaced with + `OPTIONAL_STOP`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + Controlled vocabulary for FunctionalMode + + + + + + + {{block(Component)}} is currently producing product, ready to + produce product, or its current intended use is to be producing + product. + + + + + + + {{block(Component)}} is not currently producing product. It is being + prepared or modified to begin production of product. + + + + + + + {{block(Component)}} is not currently producing product. Typically, + it has completed the production of a product and is being modified + or returned to a neutral state such that it may then be prepared to + begin production of a different product. + + + + + + + {{block(Component)}} is not currently producing product. It is + currently being repaired, waiting to be repaired, or has not yet + been returned to a normal production status after maintenance has + been performed. + + + + + + + {{block(Component)}} is being used to prove-out a new process, + testing of equipment or processes, or any other active use that does + not result in the production of product. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + Controlled vocabulary for PartDetect + + + + + + + part or work piece is detected or is present. + + + + + + + part or work piece is not detected or is not present. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for PathMode + + + + + + + path is operating independently and without the influence of another + path. + + + + + + + path provides information or state values that influences the + operation of other {{block(DataItem)}} of similar type. + + + + + + + physical or logical parts which are not physically connected to each + other but are operating together. + + + + + + + axes associated with the path are mirroring the motion of the + `MASTER` path. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + Controlled vocabulary for PowerState + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is present and + active. + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is not present + or is disconnected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + Controlled vocabulary for PowerStatus + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Controlled vocabulary for ProgramEdit + + + + + + + {{block(Controller)}} is in the program edit mode. + + + + + + + {{block(Controller)}} is capable of entering the program edit mode + and no function is inhibiting a change to that mode. + + + + + + + {{block(Controller)}} is being inhibited by a function from entering + the program edit mode. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Controlled vocabulary for ProgramLocationType + + + + + + + managed by the controller. + + + + + + + not managed by the controller. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Controlled vocabulary for RotaryMode + + + + + + + axis is functioning as a spindle. + + + + + + + axis is configured to index. + + + + + + + position of the axis is being interpolated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Controlled vocabulary for SpindleInterlock + + + + + + + power has been removed and the spindle cannot be operated. + + + + + + + spindle has not been deactivated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + {{def(EventEnum::USER)}} + + + + + + + + + + {{def(EventEnum::USER)}} + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + Controlled vocabulary for WaitState + + + + + + + execution is waiting while the equipment is powering up and is not + currently available to begin producing parts or products. + + + + + + + execution is waiting while the equipment is powering down but has + not fully reached a stopped state. + + + + + + + execution is waiting while one or more discrete workpieces are being + loaded. + + + + + + + execution is waiting while one or more discrete workpieces are being + unloaded. + + + + + + + execution is waiting while a tool or tooling is being loaded. + + + + + + + execution is waiting while a tool or tooling is being unloaded. + + + + + + + execution is waiting while material is being loaded. + + + + + + + execution is waiting while material is being unloaded. + + + + + + + execution is waiting while another process is completed before the + execution can resume. + + + + + + + execution is waiting while the equipment is pausing but the piece of + equipment has not yet reached a fully paused state. + + + + + + + execution is waiting while the equipment is resuming the production + cycle but has not yet resumed execution. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Controlled vocabulary for PartStatus + + + + + + + part conforms to given requirements. + + + + + + + part does not conform to some given requirements. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Controlled vocabulary for ConnectionStatus + + + + + + + no connection at all. + + + + + + + {{term(agent)}} is waiting for a connection request from an + {{term(adapter)}}. + + + + + + + open connection. The normal state for the data transfer phase of the + connection. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Controlled vocabulary for PartProcessingState + + + + + + + part occurrence is not actively being processed, but the processing + has not ended. Processing requirements exist that have not yet been + fulfilled. This is the default entry state when the part occurrence + is originally received. In some cases, the part occurrence may + return to this state while it waits for additional processing to be + performed. + + + + + + + part occurrence is actively being processed. + + + + + + + part occurrence is no longer being processed. A general state when + the reason for termination is unknown. + + + + + + + part occurrence has completed processing successfully. + + + + + + + process has been stopped during the processing. The part occurrence + will require special treatment. + + + + + + + processing of the part occurrence has come to a premature end. + + + + + + + terminal state when the part occurrence has been removed from the + equipment by an external entity and it no longer exists at the + equipment. + + + + + + + part occurrence has been skipped for processing on the piece of + equipment. + + + + + + + part occurrence has been processed completely. However, the + processing may have a problem. + + + + + + + part occurrence is waiting for transit. + + + + + + + part occurrence is being transported to its destination. + + + + + + + part occurrence has been placed at its designated destination. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Controlled vocabulary for ProcessState + + + + + + + device is preparing to execute the process occurrence. + + + + + + + process occurrence is ready to be executed. + + + + + + + process occurrence is actively executing. + + + + + + + process occurrence is now finished. + + + + + + + process occurrence has been stopped and may be resumed. + + + + + + + process occurrence has come to a premature end and cannot be + resumed. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Controlled vocabulary for ValveState + + + + + + + {{block(ValveState)}} where flow is allowed and the aperture is + static. > Note: For a binary value, `OPEN` indicates the valve + has the maximum possible aperture. + + + + + + + valve is transitioning from a `CLOSED` state to an `OPEN` state. + + + + + + + {{block(ValveState)}} where flow is not possible, the aperture is + static, and the valve is completely shut. + + + + + + + valve is transitioning from an `OPEN` state to a `CLOSED` state. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + Controlled vocabulary for LockState + + + + + + + mechanism is engaged and preventing the associated + {{block(Component)}} from being opened or operated. + + + + + + + mechanism is disengaged and the associated {{block(Component)}} is + able to be opened or operated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Controlled vocabulary for OperatingMode + + + + + + + automatically execute instructions from a recipe or program. > + Note: Setpoint comes from a recipe. + + + + + + + execute instructions from an external agent or person. > Note 1 + to entry: Valve or switch is manipulated by an agent/person. > + Note 2 to entry: Direct control of the PID output. % of the range: A + user manually sets the % output, not the setpoint. + + + + + + + executes a single instruction from a recipe or program. > Note 1 + to entry: Setpoint is entered and fixed, but the PID is controlling. + > Note 2 to entry: Still goes through the PID control system. + > Note 3 to entry: Manual fixed entry from a recipe. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Controlled vocabulary for PartCountType + + + + + + + count is of individual items. + + + + + + + pre-specified group of items. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + Controlled vocabulary for LeakDetect + + + + + + + leak is currently being detected. + + + + + + + leak is currently not being detected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Controlled vocabulary for BatteryState + + + + + + + {{block(Component)}} is at it's maximum rated charge level. + + + + + + + {{block(Component)}}'s charge is increasing. + + + + + + + {{block(Component)}}'s charge is decreasing. + + + + + + + {{block(Component)}} is at it's minimum charge level. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Controlled vocabulary for CharacteristicStatus + + + + + + + measurement is within acceptable tolerances. + + + + + + + measurement is not within acceptable tolerances. + + + + + + + failed, but acceptable constraints achievable by utilizing + additional manufacturing processes. + + + + + + + measurement is indeterminate due to an equipment failure. + + + + + + + measurement cannot be determined. + + + + + + + measurement cannot be evaluated. + + + + + + + nominal provided without tolerance limits. {{cite(QIF 3:2018 + 5.10.2.6)}} + + + + + + + status of measurement cannot be determined. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Controlled vocabulary for UncertaintyType + + + + + + + {{term(combined standard uncertainty)}}. + + + + + + + {{term(standard uncertainty)}} using arithmetic mean or average the + observations. {{cite(JCGM 100:2008 4.2)}} + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Controlled vocabulary for InterfaceState + + + + + + + {{block(Interface)}} is currently operational and performing as + expected. + + + + + + + {{block(Interface)}} is currently not operational. + + + + + + + Value is indeterminate + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + The target rate a value can be sampled + + + + + + + + The number of items in the list + + + + + + + + Common floating point sample value + + + + + + + + Common floating point sample value + + + + + + + + Description + + + + + + + The rate the waveform was sampled at, default back to the value given + in the data item + + + + + + + An optional indicator that the event or sample was reset + + + + + + + The statistical operation on this data + + + + + + + The number of seconds since the reset of the statistic + + + + + + + + Description + + + + + + + A sample with a single floating point value + + + + + + + + + + + + + + A sample with a single floating point value + + + + + + + A sample with a three tuple floating point value + + + + + + + + + + + + + + A sample with a three tuple floating point value + + + + + + + The abstract waveform + + + + + + + + The number of samples + + + + + + + + + + The abstract waveform + + + + + + + Description + + + + + + + + + + + + + + Description + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Example + + + + + + + + + + Example + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Description + + + + + + + + + + Description + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + The description of the Condition + + + + + + + + The device's severity + + + + + + + + Identifier of an individual condition activation provided by a piece of + equipment + + + + + + + + A qualifier for the condition + + + + + + + The value is too high + + + + + + + The value is too low + + + + + + + + + Description + + + + + + + + + type of the power source. + + + + + + + The component specific Notifcation code + + + + + + + The component specific Notifcation code + + + + + + + An optional attribute that helps qualify the condition + + + + + + + The statistical operation on this data + + + + + + + + + + Description + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + + Identifier of an individual condition activation provided by a + piece of equipment + + + + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + The conditon can not be determined. + + + + + + + + + + The conditon can not be determined. + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + The tool location + + + + + + + + The number referenced in the program for this tool + + + + + + + + The number of times the cutter has been reconditioned + + + + + + + + The code for the connection to the machine + + + + + + + + The tool group associated with the tool + + + + + + + + A speed in RPM or mm/s + + + + + + + + + + A measurement value + + + + + + + + + + The number of location units required to hold this tool + + + + + + + + A measurement value + + + + + + + + The tool identifier + + + + + + + + The number of cutting edges + + + + + + + + The number of additional locations taken by a tool + + + + + + + + The life of the tool in time, wear, or parts + + + + + + + + An identifier for the insert + + + + + + + + A single or range of indexes. A range can be a comma separated set of + individual elements as in "1,2,3,4", or as a inclusive range + of values as in "1-10" or multiple ranges "1-4,6-10" + + + + + + + + + + A minimum value + + + + + + + + A maximum value + + + + + + + + A nominal value + + + + + + + + The material for a cutting item + + + + + + + + A maximum count value + + + + + + + + A application specific code + + + + + + + + A comman delimited list of manufactures + + + + + + + + A relationship + + + + + + + + The format of the definition + + + + + + + The definition will be provided in EXPRESS format + + + + + + + The definition will be provided in XML + + + + + + + The definition will be provided in uninterpreted TEXT + + + + + + + The definition will be provided in an unspecified format + + + + + + + + + The state of the tool. These can be combined to define the complete + cutting tool state + + + + + + + The tool is new + + + + + + + The cutting tool is available for use + + + + + + + The cutting tool is unavailable for use + + + + + + + The cutting tool is assigned to this proces + + + + + + + The cutting tool is NOT assigned to this device + + + + + + + The tool has been measured + + + + + + + An unregisterd state + + + + + + + The tool is being reconditioned + + + + + + + The tool is used + + + + + + + The tool is dead + + + + + + + The tool is currently out being reconditioned or sharpened + + + + + + + The tool is broken + + + + + + + The status of this cutter is undetermined + + + + + + + + + The direction of tool life count + + + + + + + The tool life counts up from the 0 to maximum + + + + + + + The tool life counts down from maximum to 0 + + + + + + + + + The direction of tool life count + + + + + + + The tool life measured in minutes + + + + + + + The tool life measured in parts made + + + + + + + Measurement of tool life in tool wear + + + + + + + + + The type of tool location + + + + + + + A location in a tool magazine. updated + + + + + + + A location in a turret, tool bar, or tool rack. updated + + + + + + + A location within a tool crib. updated + + + + + + + A location associated with a spindle + + + + + + + A location for a tool awaiting transfer from a tool magazine to + spindle or a turret + + + + + + + A location for a tool removed from a spindle or turret and awaiting + return to a tool magazine + + + + + + + A location for a tool awaiting transfer to a tool magazine or turret + from outside of the piece of equipment. + + + + + + + A location for a tool removed from a tool magazine or turret + awaiting transfer to a location outside of the piece of equipment. + + + + + + + A location for a tool that is no longer useable and is awaiting + removal from a tool magazine or turret. + + + + + + + A location associated with an end effector + + + + + + + + + detailed structure of the cutting tool which is static during its + lifecycle. {{cite(ISO 13399)}}. + + + + + + + Any elements + + + + + + + + identifies the expected representation of the enclosed data. + + + + + + + + {{block(Asset)}} that physically removes the material from the workpiece + by shear deformation. + + + + + + + + + See {{sect(Description)}}. + + + + + + + + + detailed structure of the cutting tool which is static + during its lifecycle. {{cite(ISO 13399)}}. + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine + tool, presetter) and statistical process control + applications. Life cycle data will not remain static, but + will change periodically when a tool is used or measured. + + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine tool, + presetter) and statistical process control applications. Life + cycle data will not remain static, but will change + periodically when a tool is used or measured. + + + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + The manufacturer of this asset + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + {{block(Asset)}} that physically removes the material from the workpiece + by shear deformation. + + + + + + + {{block(Asset)}} that describes the static cutting tool geometries and + nominal values as one would expect from a tool catalog. + + + + + + + + + See {{sect(Description)}}. + + + + + + + + + detailed structure of the cutting tool which is static + during its lifecycle. {{cite(ISO 13399)}}. + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine + tool, presetter) and statistical process control + applications. Life cycle data will not remain static, but + will change periodically when a tool is used or measured. + + + + + + + + data regarding the application or use of the tool. This data + is provided by various pieces of equipment (i.e. machine tool, + presetter) and statistical process control applications. Life + cycle data will not remain static, but will change + periodically when a tool is used or measured. + + + + + + + + + identifier for a class of cutting tools. + + + + + + + + + + {{block(Asset)}} that describes the static cutting tool geometries and + nominal values as one would expect from a tool catalog. + + + + + + + A archetypical cutting tool life cycle definition + + + + + + + number of times the cutter has been reconditioned. + + + + + + + The life of the cutting tool assembly + + + + + + + tool group this tool is assigned in the part program. + + + + + + + number of the tool as referenced in the part program. + + + + + + + constrained process spindle speed for the tool in + revolutions/minute. The {{property(ProcessSpindleSpeed::value)}} + **MAY** contain the nominal process target spindle speed if + available. If {{block(ProcessSpindleSpeed)}} is provided, at least + one value of {{property(ProcessSpindleSpeed::maximum)}}, + {{property(ProcessSpindleSpeed::nominal)}}, or + {{property(ProcessSpindleSpeed::minimum)}} **MUST** be specified. + + + + + + + constrained process feed rate for the tool in mm/s. The + {{property(ProcessFeedRate::value)}} **MAY** contain the nominal + process target feed rate if available. If {{block(ProcessFeedRate)}} + is provided, at least one value of + {{property(ProcessFeedRate::maximum)}}, + {{property(ProcessFeedRate::nominal)}}, or + {{property(ProcessFeedRate::minimum)}} **MUST** be specified. + + + + + + + identifier for the capability to connect any component of the + cutting tool together, except Assembly Items, on the machine side. + Code: `CCMS` + + + + + + + {{block(Measurements)}} groups one or more {{block(Measurement)}} + subtypes. See {{sect(Measurement)}}. + + + + + + + {{block(CuttingItems)}} groups one or more {{block(CuttingItem)}} + entities. See {{sect(CuttingItem)}} and {{package(Cutting Item)}} + for more detail. + + + + + + + + + data regarding the application or use of the tool. This data is provided + by various pieces of equipment (i.e. machine tool, presetter) and + statistical process control applications. Life cycle data will not + remain static, but will change periodically when a tool is used or + measured. + + + + + + + {{block(CutterStatus)}} provides the status of the assembly and + {{term(organize)}} one or more {{block(Status)}} entities. See + {{sect(Status)}}. The following combinations of {{block(Status)}} + entities **MUST NOT** occur for a {{block(CutterStatus)}}: * `NEW` + **MUST NOT** be used with `USED`, `RECONDITIONED`, or `EXPIRED`. * + `UNKNOWN` **MUST NOT** be used with any other status. * `ALLOCATED` + and `UNALLOCATED` **MUST NOT** be used together. * `AVAILABLE` and + `UNAVAILABLE` **MUST NOT** be used together. * If the tool is + `EXPIRED`, `BROKEN`, or `NOT_REGISTERED` it **MUST NOT** be + `AVAILABLE`. + + + + + + + number of times the cutter has been reconditioned. + + + + + + + Description + + + + + + + tool group this tool is assigned in the part program. + + + + + + + number of the tool as referenced in the part program. + + + + + + + Description + + + + + + + constrained process spindle speed for the tool in + revolutions/minute. The {{property(ProcessSpindleSpeed::value)}} + **MAY** contain the nominal process target spindle speed if + available. If {{block(ProcessSpindleSpeed)}} is provided, at least + one value of {{property(ProcessSpindleSpeed::maximum)}}, + {{property(ProcessSpindleSpeed::nominal)}}, or + {{property(ProcessSpindleSpeed::minimum)}} **MUST** be specified. + + + + + + + constrained process feed rate for the tool in mm/s. The + {{property(ProcessFeedRate::value)}} **MAY** contain the nominal + process target feed rate if available. If {{block(ProcessFeedRate)}} + is provided, at least one value of + {{property(ProcessFeedRate::maximum)}}, + {{property(ProcessFeedRate::nominal)}}, or + {{property(ProcessFeedRate::minimum)}} **MUST** be specified. + + + + + + + identifier for the capability to connect any component of the + cutting tool together, except Assembly Items, on the machine side. + Code: `CCMS` + + + + + + + {{block(Measurements)}} groups one or more {{block(Measurement)}} + subtypes. See {{sect(Measurement)}}. + + + + + + + {{block(CuttingItems)}} groups one or more {{block(CuttingItem)}} + entities. See {{sect(CuttingItem)}} and {{package(Cutting Item)}} + for more detail. + + + + + + + + + reference information about the {{property(Asset::assetId)}} and/or the + URL of the data source of {{block(CuttingToolArchetype)}}. + + + + + + + + identifies the {{block(Component)}}, {{block(DataItem)}}, or + {{block(Composition)}} from which a measured value originates. + + + + + + + + + + {{block(CutterStatus)}} provides the status of the assembly and + {{term(organize)}} one or more {{block(Status)}} entities. See + {{sect(Status)}}. The following combinations of {{block(Status)}} + entities **MUST NOT** occur for a {{block(CutterStatus)}}: * `NEW` + **MUST NOT** be used with `USED`, `RECONDITIONED`, or `EXPIRED`. * + `UNKNOWN` **MUST NOT** be used with any other status. * `ALLOCATED` and + `UNALLOCATED` **MUST NOT** be used together. * `AVAILABLE` and + `UNAVAILABLE` **MUST NOT** be used together. * If the tool is `EXPIRED`, + `BROKEN`, or `NOT_REGISTERED` it **MUST NOT** be `AVAILABLE`. + + + + + + + status of the cutting tool. + + + + + + + + + Description + + + + + + + + The type of location + + + + + + + number of locations at lower index values from this location. + + + + + + + number of locations at higher index value from this location. + + + + + + + Description + + + + + + + Description + + + + + + + Description + + + + + + + The tool bar associated with a tool + + + + + + + Description + + + + + + + + + + number of times the cutter has been reconditioned. + + + + + + + + The maximum number of times this tool can be reconditioned + + + + + + + + + + constrained process spindle speed for the tool in revolutions/minute. + The {{property(ProcessSpindleSpeed::value)}} **MAY** contain the nominal + process target spindle speed if available. If + {{block(ProcessSpindleSpeed)}} is provided, at least one value of + {{property(ProcessSpindleSpeed::maximum)}}, + {{property(ProcessSpindleSpeed::nominal)}}, or + {{property(ProcessSpindleSpeed::minimum)}} **MUST** be specified. + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + constrained process feed rate for the tool in mm/s. The + {{property(ProcessFeedRate::value)}} **MAY** contain the nominal process + target feed rate if available. If {{block(ProcessFeedRate)}} is + provided, at least one value of {{property(ProcessFeedRate::maximum)}}, + {{property(ProcessFeedRate::nominal)}}, or + {{property(ProcessFeedRate::minimum)}} **MUST** be specified. + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + Description + + + + + + + + The number of significant digits + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The native units for the measurement, if different from units + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + Description + + + + + + + Measurements for both the assembly and the cutting item + + + + + + + + + + Measurements for both the assembly and the cutting item + + + + + + + Measurements for the assembly + + + + + + + + + + Measurements for the assembly + + + + + + + Measurements for the cutting item + + + + + + + + + + Measurements for the cutting item + + + + + + + A collection of assembly measurements + + + + + + + + + + + dimension from the yz-plane to the furthest point of the tool item or + adaptive item measured in the -X direction. + + + + + + + + + + dimension from the yz-plane to the furthest point of the tool item or + adaptive item measured in the -X direction. + + + + + + + total weight of the cutting tool in grams. The force exerted by the mass + of the cutting tool. + + + + + + + + + + total weight of the cutting tool in grams. The force exerted by the mass + of the cutting tool. + + + + + + + distance from the gauge plane or from the end of the shank to the + furthest point on the tool, if a gauge plane does not exist, to the + cutting reference point determined by the main function of the tool. The + {{block(CuttingTool)}} functional length will be the length of the + entire tool, not a single cutting item. Each {{block(CuttingItem)}} can + have an independent {{block(FunctionalLength)}} represented in its + measurements. + + + + + + + + + + distance from the gauge plane or from the end of the shank to the + furthest point on the tool, if a gauge plane does not exist, to the + cutting reference point determined by the main function of the tool. The + {{block(CuttingTool)}} functional length will be the length of the + entire tool, not a single cutting item. Each {{block(CuttingItem)}} can + have an independent {{block(FunctionalLength)}} represented in its + measurements. + + + + + + + largest diameter of the body of a tool item. + + + + + + + + + + largest diameter of the body of a tool item. + + + + + + + distance measured along the X axis from that point of the item closest + to the workpiece, including the cutting item for a tool item but + excluding a protruding locking mechanism for an adaptive item, to either + the front of the flange on a flanged body or the beginning of the + connection interface feature on the machine side for cylindrical or + prismatic shanks. + + + + + + + + + + distance measured along the X axis from that point of the item closest + to the workpiece, including the cutting item for a tool item but + excluding a protruding locking mechanism for an adaptive item, to either + the front of the flange on a flanged body or the beginning of the + connection interface feature on the machine side for cylindrical or + prismatic shanks. + + + + + + + maximum diameter of a circle on which the defined point Pk of each of + the master inserts is located on a tool item. The normal of the machined + peripheral surface points towards the axis of the cutting tool. + + + + + + + + + + maximum diameter of a circle on which the defined point Pk of each of + the master inserts is located on a tool item. The normal of the machined + peripheral surface points towards the axis of the cutting tool. + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + maximum engagement of the cutting edge or edges with the workpiece + measured perpendicular to the feed motion. + + + + + + + + + + maximum engagement of the cutting edge or edges with the workpiece + measured perpendicular to the feed motion. + + + + + + + largest length dimension of the cutting tool including the master insert + where applicable. + + + + + + + + + + largest length dimension of the cutting tool including the master insert + where applicable. + + + + + + + dimension of the diameter of a cylindrical portion of a tool item or an + adaptive item that can participate in a connection. + + + + + + + + + + dimension of the diameter of a cylindrical portion of a tool item or an + adaptive item that can participate in a connection. + + + + + + + dimension of the height of the shank. + + + + + + + + + + dimension of the height of the shank. + + + + + + + dimension of the length of the shank. + + + + + + + + + + dimension of the length of the shank. + + + + + + + maximum length of a cutting tool that can be used in a particular + cutting operation including the non-cutting portions of the tool. + + + + + + + + + + maximum length of a cutting tool that can be used in a particular + cutting operation including the non-cutting portions of the tool. + + + + + + + Abstract cutter life + + + + + + + + One of time, part count, or wear + + + + + + + The count up or count down + + + + + + + {{term(condition state)}} that requires concern and supervision + and may become hazardous if no action is taken. + + + + + + + Maximum tool life + + + + + + + The life when the tool is new + + + + + + + + + + A collection of assembly measurements + + + + + + + + + + + diameter of a circle on which the defined point Pk located on this + cutting tool. The normal of the machined peripheral surface points + towards the axis of the cutting tool. + + + + + + + + + + diameter of a circle on which the defined point Pk located on this + cutting tool. The normal of the machined peripheral surface points + towards the axis of the cutting tool. + + + + + + + nominal radius of a rounded corner measured in the X Y-plane. + + + + + + + + + + nominal radius of a rounded corner measured in the X Y-plane. + + + + + + + theoretical length of the cutting edge of a cutting item over sharp + corners. + + + + + + + + + + theoretical length of the cutting edge of a cutting item over sharp + corners. + + + + + + + distance from the basal plane of the tool item to the cutting point. + + + + + + + + + + distance from the basal plane of the tool item to the cutting point. + + + + + + + theoretical sharp point of the cutting tool from which the major + functional dimensions are taken. + + + + + + + + + + theoretical sharp point of the cutting tool from which the major + functional dimensions are taken. + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + + + + dimension between two parallel tangents on the outside edge of a flange. + + + + + + + distance between the cutting reference point and the rear backing + surface of a turning tool or the axis of a boring bar. + + + + + + + + + + distance between the cutting reference point and the rear backing + surface of a turning tool or the axis of a boring bar. + + + + + + + angle between the tool rake plane and a plane parallel to the xy-plane + measured in the tool cutting edge plane + + + + + + + + + + angle between the tool rake plane and a plane parallel to the xy-plane + measured in the tool cutting edge plane + + + + + + + diameter of a circle to which all edges of a equilateral and round + regular insert are tangential. + + + + + + + + + + diameter of a circle to which all edges of a equilateral and round + regular insert are tangential. + + + + + + + angle between the major cutting edge and the same cutting edge rotated + by 180 degrees about the tool axis. + + + + + + + + + + angle between the major cutting edge and the same cutting edge rotated + by 180 degrees about the tool axis. + + + + + + + length of a portion of a stepped tool that is related to a corresponding + cutting diameter measured from the cutting reference point of that + cutting diameter to the point on the next cutting edge at which the + diameter starts to change. + + + + + + + + + + length of a portion of a stepped tool that is related to a corresponding + cutting diameter measured from the cutting reference point of that + cutting diameter to the point on the next cutting edge at which the + diameter starts to change. + + + + + + + angle between a major edge on a step of a stepped tool and the same + cutting edge rotated 180 degrees about its tool axis. + + + + + + + + + + angle between a major edge on a step of a stepped tool and the same + cutting edge rotated 180 degrees about its tool axis. + + + + + + + angle between the tool cutting edge plane and the tool feed plane + measured in a plane parallel the xy-plane. + + + + + + + + + + angle between the tool cutting edge plane and the tool feed plane + measured in a plane parallel the xy-plane. + + + + + + + angle between the tool cutting edge plane and a plane perpendicular to + the tool feed plane measured in a plane parallel the xy-plane. + + + + + + + + + + angle between the tool cutting edge plane and a plane perpendicular to + the tool feed plane measured in a plane parallel the xy-plane. + + + + + + + measure of the length of a wiper edge of a cutting item. + + + + + + + + + + measure of the length of a wiper edge of a cutting item. + + + + + + + angle of the tool with respect to the workpiece for a given process. The + value is application specific. + + + + + + + + + + angle between the driving mechanism locator on a tool item and the main + cutting edge. + + + + + + + + + + The location of the cutting item - not yet restricted. + + + + + + + + {{block(CuttingItems)}} groups one or more {{block(CuttingItem)}} + entities. See {{sect(CuttingItem)}} and {{package(Cutting Item)}} for + more detail. + + + + + + + part of of the tool that physically removes the material from the + workpiece by shear deformation. + + + + + + + + The number of edges + + + + + + + + part of of the tool that physically removes the material from the + workpiece by shear deformation. + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(CutterStatus)}} provides the status of the assembly and + {{term(organize)}} one or more {{block(Status)}} entities. See + {{sect(Status)}}. The following combinations of {{block(Status)}} + entities **MUST NOT** occur for a {{block(CutterStatus)}}: * `NEW` + **MUST NOT** be used with `USED`, `RECONDITIONED`, or `EXPIRED`. * + `UNKNOWN` **MUST NOT** be used with any other status. * `ALLOCATED` + and `UNALLOCATED` **MUST NOT** be used together. * `AVAILABLE` and + `UNAVAILABLE` **MUST NOT** be used together. * If the tool is + `EXPIRED`, `BROKEN`, or `NOT_REGISTERED` it **MUST NOT** be + `AVAILABLE`. + + + + + + + free form description of the location on the cutting tool. For + clarity, the words `FLUTE`, `INSERT`, and `CARTRIDGE` **SHOULD** be + used to assist in noting the location of a {{block(CuttingItem)}}. + {{property(CuttingItem::Locus)}} **MAY** be any free form string, + but **SHOULD** adhere to the following rules: * The location + numbering **SHOULD** start at the furthest {{block(CuttingItem)}} + and work it’s way back to the {{block(CuttingItem)}} closest to the + gauge line. * Flutes **SHOULD** be identified as such using the word + `FLUTE`:. For example: `FLUTE`: 1, `INSERT`: 2 - would indicate the + first flute and the second furthest insert from the end of the tool + on that flute. * Other designations such as `CARTRIDGE` **MAY** be + included, but should be identified using upper case and followed by + a colon (:). + + + + + + + life of a {{block(CuttingItem)}}. + + + + + + + tool group this tool is assigned in the part program. + + + + + + + {{block(Measurements)}} groups one or more {{block(Measurement)}} + subtypes. See {{sect(Measurement)}}. + + + + + + + + The unique identifier of this insert in this assembly + + + + + + + The manufacturer identifier of this cutting item + + + + + + + The material used for the cutting item + + + + + + + The manufacturer of this asset + + + + + + + + The version of the file + + + + + + + + The mime type of the file + + + + + + + + The size in bytes of the file + + + + + + + + The name of the file + + + + + + + + Extended tyoe for The category of application that will use this file + + + + + + + + + + The category of application that will use this file + + + + + + + Files regarding the fully assembled product + + + + + + + Device related files + + + + + + + Files relating to the handling of material + + + + + + + File relating to equipment maintenance + + + + + + + Files relating to a part + + + + + + + Files related to the manufacturing process + + + + + + + Files related to the quality inspection + + + + + + + Files related to the setup of a process + + + + + + + + + The category of application that will use this file + + + + + + + + Extended tyoe for The type classification of a file + + + + + + + + + + The type classification of a file + + + + + + + Computer aided design files or drawings + + + + + + + Generic data + + + + + + + Documentation regarding a category of file + + + + + + + User instructions regarding the execution of a task + + + + + + + The data related to the history of a machine or process + + + + + + + Machine instructions to perform a process + + + + + + + + + The type classification of a file + + + + + + + + {{block(AbstractFile)}} type that provides information common to all + versions of a file. + + + + + + + + + {{block(FileProperties)}} groups one or more + {{block(FileProperty)}} entities for a {{block(File)}}. See + {{sect(FileProperty)}}. + + + + + + + {{block(FileComments)}} groups one or more + {{block(FileComment)}} entities for a {{block(File)}}. See + {{sect(FileComment)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + The mime type of the file + + + + + + + The classification of this file + + + + + + + The sub classification of this file + + + + + + + + + + {{block(AbstractFile)}} type that provides information common to all + versions of a file. + + + + + + + {{block(FileProperties)}} groups one or more {{block(FileProperty)}} + entities for a {{block(File)}}. See {{sect(FileProperty)}}. + + + + + + + key-value pair providing additional metadata about a + {{block(File)}}. + + + + + + + + + The value of a file property + + + + + + + + key-value pair providing additional metadata about a {{block(File)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + + + + File state + + + + + + + used for processes other than production or otherwise defined. + + + + + + + used for production processes + + + + + + + the content is modified from PRODUCTION or EXPERIMENTAL (Note: To + capture northbound changes. execution -> prod engineering) + + + + + + + + + An X501 Public Key + + + + + + + + A secure hash + + + + + + + + A file time + + + + + + + + {{block(AbstractFile)}} type that provides information about the + {{block(File)}} instance and its {{term(URL)}}. + + + + + + + + + {{block(FileProperties)}} groups one or more + {{block(FileProperty)}} entities for a {{block(File)}}. See + {{sect(FileProperty)}}. + + + + + + + {{block(FileComments)}} groups one or more + {{block(FileComment)}} entities for a {{block(File)}}. See + {{sect(FileComment)}}. + + + + + + + {{term(URL)}} reference to the file location. + + + + + + + secure hash of the file. + + + + + + + public key used to verify the signature. + + + + + + + {{block(Destinations)}} groups one or more + {{block(Destination)}} entities. See {{sect(Destination)}}. + + + + + + + time the file was created. + + + + + + + time the file was modified. + + + + + + + + identifier of the maintenance activity. + + + + + + + The mime type of the file + + + + + + + The classification of this file + + + + + + + The sub classification of this file + + + + + + + The size in bytes + + + + + + + The version identifier + + + + + + + The file state + + + + + + + + + + {{block(AbstractFile)}} type that provides information about the + {{block(File)}} instance and its {{term(URL)}}. + + + + + + + {{term(URL)}} reference to the file location. + + + + + + + + {{term(URL)}} giving the location of the image file. + + + + + + + Description + + + + + + + + + + Organizes file destinations + + + + + + + reference to the target {{block(Device)}} for this {{block(File)}}. + + + + + + + + + The Destination is a reference to the target Device for this File + + + + + + + + + + {{block(FileComments)}} groups one or more {{block(FileComment)}} + entities for a {{block(File)}}. See {{sect(FileComment)}}. + + + + + + + remark or interpretation for human interpretation associated with a + {{block(File)}} or {{block(FileArchetype)}}. + + + + + + + + + the text of the comment + + + + + + + + remark or interpretation for human interpretation associated with a + {{block(File)}} or {{block(FileArchetype)}}. + + + + + + + + The time the comment was made + + + + + + + + + + Extended tyoe for contained QIF Document type as defined in the QIF + Standard. + + + + + + + + + + contained QIF Document type as defined in the QIF Standard. + + + + + + + + + + + + + + + contained QIF Document type as defined in the QIF Standard. + + + + + + + + {{block(Asset)}} that carries the QIF Document. + + + + + + + + + + + + + + + The unique identifier for the material + + + + + + + + + + {{block(Asset)}} that carries the QIF Document. + + + + + + + + + + + + any element + + + + + + + + + The type of the material container. + + + + + + + + The serial number of the material container + + + + + + + + The ISO process type supported by this {{term(raw material)}} + + + + + + + + The type of material. + + + + + + + + The name of the raw feed stock manufacturer. + + + + + + + + The manufacturing date of the raw feed stock from the feed stock + manufacturer. + + + + + + + + The lot code of the raw feed stock from the feed stock manufacturer. + + + + + + + + The ASTM standard code that the material complies with. + + + + + + + + The lot code of the material contained within the material container. + + + + + + + + The form of the material in the material container. + + + + + + + + The date when the material container was first used. + + + + + + + + The date when the material container was last used. + + + + + + + + The amount of material initially placed in the material container when + manufactured. + + + + + + + + The dimension of material initially placed in the material container + when manufactured. + + + + + + + + The quantity of material initially placed in the material container when + manufactured. + + + + + + + + The quantity of material currently contained in the material container + + + + + + + + The dimension of material currently contained in the material container + + + + + + + + The quantity of material currently contained in the material container + + + + + + + + Extended tyoe for form of the {{term(raw material)}}. + + + + + + + + + + form of the {{term(raw material)}}. + + + + + + + + + + + + + + + + + + form of the {{term(raw material)}}. + + + + + + + + material used as the {{block(RawMaterial)}} + + + + + + + manufacturer's lot code of the material. + + + + + + + name of the material manufacturer. + + + + + + + manufacturing date of the material from the material manufacturer. + + + + + + + lot code of the raw feed stock for the material, from the feed stock + manufacturer. + + + + + + + {{term(ASTM)}} standard code that the material complies with. + + + + + + + + The unique identifier for the material + + + + + + + identifier of the maintenance activity. + + + + + + + The type of material. + + + + + + + + {{block(Asset)}} that represents {{term(raw material)}}. + + + + + + + + + form of the {{term(raw material)}}. + + + + + + + {{block(Material)}} has existing usable volume. + + + + + + + manufacturing date of the material from the material + manufacturer. + + + + + + + date {{term(raw material)}} was first used. + + + + + + + date {{term(raw material)}} was last used. + + + + + + + amount of material initially placed in {{term(raw material)}} + when manufactured. + + + + + + + dimension of material initially placed in {{term(raw material)}} + when manufactured. + + + + + + + quantity of material initially placed in {{term(raw material)}} + when manufactured. + + + + + + + amount of material currently in {{term(raw material)}}. + + + + + + + dimension of material currently in {{term(raw material)}}. + + + + + + + quantity of material currently in {{term(raw material)}}. + + + + + + + {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, + materials, or other types of goods. + + + + + + + + identifier of the maintenance activity. + + + + + + + The type of container holding the {{term(raw material)}}. + + + + + + + The ISO process type supported by this {{term(raw material)}}. + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + {{block(Asset)}} that represents {{term(raw material)}}. + + + + + + + property that determines the characteristic or behavior of an entity. + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST NOT** + be used in conjunction with any other {{block(Constraint)}} + elements. + + + + + + + + The identifier of the parameter + + + + + + + identifier of the maintenance activity. + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + {{block(Parameters)}} groups one or more {{block(Parameter)}} entities. + See {{sect(Parameter)}}. + + + + + + + property that determines the characteristic or behavior of an + entity. + + + + + + + + + set of {{block(Parameter)}}s. + + + + + + + {{block(Parameters)}} groups one or more {{block(Parameter)}} + entities. See {{sect(Parameter)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + + {{block(ParameterSets)}} groups one or more {{block(ParameterSet)}} + entities. See {{sect(ParameterSet)}}. + + + + + + + set of {{block(Parameter)}}s. + + + + + + + + + set of {{block(ParameterSet)}}s that govern the functionality of the + related {{block(Component)}}. + + + + + + + + + {{block(ParameterSets)}} groups one or more + {{block(ParameterSet)}} entities. See {{sect(ParameterSet)}}. + + + + + + + + + + + set of {{block(ParameterSet)}}s that govern the functionality of the + related {{block(Component)}}. + + + + \ No newline at end of file diff --git a/schemas/MTConnectDevices_2.4.xsd b/schemas/MTConnectDevices_2.4.xsd new file mode 100644 index 00000000..ecfdc7d5 --- /dev/null +++ b/schemas/MTConnectDevices_2.4.xsd @@ -0,0 +1,10310 @@ + + + + + + + + root entity of an {{term(MTConnectDevices Response Document)}} that + contains the {{term(Device Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectDevices](figures/MTConnectDevices.png + "MTConnectDevices"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectDevices)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + The number of assets + + + + + + + + + + + {{block(AssetCounts)}} groups {{block(AssetCount)}} entities. + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + The type of asset + + + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + {{block(AssetCounts)}} groups {{block(AssetCount)}} entities. + + + + + + + + + The size of the agent's buffer. + + + + + + + The maximum number of assets + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + root entity of an {{term(MTConnectDevices Response Document)}} that + contains the {{term(Device Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectDevices](figures/MTConnectDevices.png + "MTConnectDevices"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectDevices)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + This section provides semantic information for the {{block(Device)}} + types. + + + + + + + + + The station id for this device + + + + + + + + The ISO 841 classification for the device + + + + + + + + The model name + + + + + + + + This section provides semantic information for the {{block(Device)}} + types. + + + + + + + Description + + + + + + + Description + + + + + + + + + Description + + + + + + + See {{sect(Description)}}. + + + + + + + technical information about an entity describing its physical + layout, functional characteristics, and relationships with other + entities. + + + + + + + + + + + + {{block(Components)}} groups one or more {{block(Component)}} + entities. + + + + + + + Compositions Model + + + + + + + References Model + + + + + + + + unique identifier for the power source. + + + + + + + The device manufacturer component name + + + + + + + The rate at which the data is sampled from the component + + + + + + + DEPRECATED: The rate at which the data is sampled from the component + + + + + + + + Description + + + + + + + The descriptive information. This can be manufacturer specific + + + + + + + The content of the description can text or XML elements + + + + + + + + name of the material manufacturer. + + + + + + + The model + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + leaf {{block(Component)}} composed of a storage or mounting location + for a tool associated with a {{block(Turret)}}, + {{block(GangToolBar)}}, or {{block(ToolRack)}}. + + + + + + + + An abstract component that has an optional uuid + + + + + + + + The component's universally unique id. + + + + + + + identifier of the maintenance activity. + + + + + + + + + + An abstract component that has an optional uuid + + + + + + + {{block(Components)}} groups one or more {{block(Component)}} entities. + + + + + + + + + + Description + + + + + + + + DEPRECATED: The device's ISO-841 classification + + + + + + + The components universally unique id. This can be composed of the + manufactures id or name and the serial number. + + + + + + + identifier of the maintenance activity. + + + + + + + MTConnect version of the {{term(Device Information Model)}} used + to configure the information to be published for a piece of + equipment in an {{term(MTConnect Response Document)}}. + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of removable part(s) of a piece + of equipment that provides supplementary or extended functionality. + + + + + + + + + + abstract {{block(Component)}} composed of removable part(s) of a piece + of equipment that provides supplementary or extended functionality. + + + + + + + See {{sect(Axis)}}. + + + + + + + + + + See {{sect(Axis)}}. + + + + + + + {{block(Loader)}} that delivers bar stock to a piece of equipment. + + + + + + + + + + {{block(Loader)}} that delivers bar stock to a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(System)}} that provides distribution and management of fluids + that remove heat from a piece of equipment. + + + + + + + + + + {{block(System)}} that provides distribution and management of fluids + that remove heat from a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Component)}} that observes the surroundings of another + {{block(Component)}}. > Note: {{block(Environmental)}} **SHOULD** be + organized by {{block(Auxillaries)}}, {{block(Systems)}} or + {{block(Parts)}} depending on the relationship to the + {{block(Component)}}. + + + + + + + + + + {{block(Component)}} that observes the surroundings of another + {{block(Component)}}. > Note: {{block(Environmental)}} **SHOULD** be + organized by {{block(Auxillaries)}}, {{block(Systems)}} or + {{block(Parts)}} depending on the relationship to the + {{block(Component)}}. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(System)}} that provides movement and distribution of pressurized + liquid throughout the piece of equipment. + + + + + + + + + + {{block(System)}} that provides movement and distribution of pressurized + liquid throughout the piece of equipment. + + + + + + + {{block(Component Types::Axis)}} that provides prismatic motion along a + fixed axis. + + + + + + + + + + {{block(Component Types::Axis)}} that provides prismatic motion along a + fixed axis. + + + + + + + {{block(Auxiliary)}} that provides movement and distribution of + materials, parts, tooling, and other items to or from a piece of + equipment. + + + + + + + + + + {{block(Auxiliary)}} that provides movement and distribution of + materials, parts, tooling, and other items to or from a piece of + equipment. + + + + + + + {{block(System)}} that provides distribution and management of fluids + used to lubricate portions of the piece of equipment. + + + + + + + + + + {{block(System)}} that provides distribution and management of fluids + used to lubricate portions of the piece of equipment. + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Resource)}} composed of an individual or individuals who either + control, support, or otherwise interface with a piece of equipment. + + + + + + + + + + {{block(Resource)}} composed of an individual or individuals who either + control, support, or otherwise interface with a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Power)}} was **DEPRECATED** in *MTConnect Version 1.1* and was + replaced by {{block(Availability)}} data item type. + + + + + + + + + + {{block(Power)}} was **DEPRECATED** in *MTConnect Version 1.1* and was + replaced by {{block(Availability)}} data item type. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of material or personnel involved + in a manufacturing process. + + + + + + + + + + abstract {{block(Component)}} composed of material or personnel involved + in a manufacturing process. + + + + + + + {{block(Component Types::Axis)}} that provides rotation about a fixed + axis. + + + + + + + + + + {{block(Component Types::Axis)}} that provides rotation about a fixed + axis. + + + + + + + This section provides semantic information for the + {{block(SensorConfiguration)}} entity. {{term(sensor)}} is a unique type + of a piece of equipment. A {{term(sensor)}} is typically comprised of + two major components: a {{term(sensor unit)}} that provides signal + processing, conversion, and communications and the {{termplural(sensing + element)}} that provides a signal or measured value. The {{term(sensor + unit)}} is modeled as a {{term(lower level)}} {{block(Component)}} + called {{block(Sensor)}}. The {{term(sensing element)}} may be modeled + as a {{block(Composition)}} element of a {{block(Sensor)}} element and + the measured value would be modeled as a {{block(DataItem)}} (See + {{sect(DataItems)}} for more information on {{block(DataItem)}} + elements). Each {{term(sensor unit)}} may have multiple + {{termplural(sensing element)}}; each representing the data for a + variety of measured values. ![Sensing Element provided as a DataItem + Example](figures/Sensing%20Element%20provided%20as%20a%20DataItem%20Example.png "Sensing Element provided as a DataItem Example"){: width="0.8"} > Note: See {{lst(example-of-sensing-element-provided-as-data-item-associated-with-a-component)}} for an {{term(XML)}} example. When a {{term(sensor unit)}} is modeled as a {{block(Component)}} or as a separate piece of equipment, it may provide additional configuration information for the {{termplural(sensor element)}} and the {{term(sensor unit)}} itself. ![Sensor for Rotary Axis Example](figures/Sensor%20for%20Rotary%20Axis%20Example.png "Sensor for Rotary Axis Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides vibration measurement data for the spindle on a piece of equipment, it could be modeled as a {{block(Sensor)}} for rotary axis named `C`. See {{lst(example-of-sensor-for-rotary-axis)}} for an {{term(XML)}} example. ![Sensor unit with Sensing Elements Example](figures/Sensor%20unit%20with%20Sensing%20Elements%20Example.png "Sensor unit with Sensing Elements Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides measurement data for multiple {{block(Component)}} elements within a piece of equipment and is not associated with any particular {{block(Component)}}, it **MAY** be modeled as an independent {{block(Component)}} and the data associated with measurements are associated with their associated {{block(Component)}} entities. See {{lst(example-of-sensor-unit-with-sensing-element)}} for an {{term(XML)}} example. {{block(Configuration)}} data provides information required for maintenance and support of the sensor. When {{block(Sensor)}} represents the {{term(sensor unit)}} for multiple {{term(sensing element)}}(s), each sensing element is represented by a {{block(Channel)}}. The {{term(sensor unit)}} itself and each {{block(Channel)}} representing one {{term(sensing element)}} **MAY** have its own configuration data. ![Sensor Configuration Example](figures/Sensor%20Configuration%20Example.png "Sensor Configuration Example"){: width="0.8"} > Note: See {{lst(example-of-configuration-data-for-sensor)}} for an {{term(XML)}} example. + + + + + + + + + + This section provides semantic information for the + {{block(SensorConfiguration)}} entity. {{term(sensor)}} is a unique type + of a piece of equipment. A {{term(sensor)}} is typically comprised of + two major components: a {{term(sensor unit)}} that provides signal + processing, conversion, and communications and the {{termplural(sensing + element)}} that provides a signal or measured value. The {{term(sensor + unit)}} is modeled as a {{term(lower level)}} {{block(Component)}} + called {{block(Sensor)}}. The {{term(sensing element)}} may be modeled + as a {{block(Composition)}} element of a {{block(Sensor)}} element and + the measured value would be modeled as a {{block(DataItem)}} (See + {{sect(DataItems)}} for more information on {{block(DataItem)}} + elements). Each {{term(sensor unit)}} may have multiple + {{termplural(sensing element)}}; each representing the data for a + variety of measured values. ![Sensing Element provided as a DataItem + Example](figures/Sensing%20Element%20provided%20as%20a%20DataItem%20Example.png "Sensing Element provided as a DataItem Example"){: width="0.8"} > Note: See {{lst(example-of-sensing-element-provided-as-data-item-associated-with-a-component)}} for an {{term(XML)}} example. When a {{term(sensor unit)}} is modeled as a {{block(Component)}} or as a separate piece of equipment, it may provide additional configuration information for the {{termplural(sensor element)}} and the {{term(sensor unit)}} itself. ![Sensor for Rotary Axis Example](figures/Sensor%20for%20Rotary%20Axis%20Example.png "Sensor for Rotary Axis Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides vibration measurement data for the spindle on a piece of equipment, it could be modeled as a {{block(Sensor)}} for rotary axis named `C`. See {{lst(example-of-sensor-for-rotary-axis)}} for an {{term(XML)}} example. ![Sensor unit with Sensing Elements Example](figures/Sensor%20unit%20with%20Sensing%20Elements%20Example.png "Sensor unit with Sensing Elements Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides measurement data for multiple {{block(Component)}} elements within a piece of equipment and is not associated with any particular {{block(Component)}}, it **MAY** be modeled as an independent {{block(Component)}} and the data associated with measurements are associated with their associated {{block(Component)}} entities. See {{lst(example-of-sensor-unit-with-sensing-element)}} for an {{term(XML)}} example. {{block(Configuration)}} data provides information required for maintenance and support of the sensor. When {{block(Sensor)}} represents the {{term(sensor unit)}} for multiple {{term(sensing element)}}(s), each sensing element is represented by a {{block(Channel)}}. The {{term(sensor unit)}} itself and each {{block(Channel)}} representing one {{term(sensing element)}} **MAY** have its own configuration data. ![Sensor Configuration Example](figures/Sensor%20Configuration%20Example.png "Sensor Configuration Example"){: width="0.8"} > Note: See {{lst(example-of-configuration-data-for-sensor)}} for an {{term(XML)}} example. + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} that is permanently integrated into the + piece of equipment. + + + + + + + + + + abstract {{block(Component)}} that is permanently integrated into the + piece of equipment. + + + + + + + {{block(Auxiliary)}} that manages, positions, stores, and delivers + tooling within a piece of equipment. + + + + + + + + + + {{block(Auxiliary)}} that manages, positions, stores, and delivers + tooling within a piece of equipment. + + + + + + + {{block(Auxiliary)}} that removes manufacturing byproducts from a piece + of equipment. + + + + + + + + + + {{block(Auxiliary)}} that removes manufacturing byproducts from a piece + of equipment. + + + + + + + {{block(Component)}} composed of part(s) comprising the rigid bodies of + the piece of equipment. + + + + + + + + + + {{block(Component)}} composed of part(s) comprising the rigid bodies of + the piece of equipment. + + + + + + + {{block(Structure)}} that provides a connection between + {{block(Component)}} entities. + + + + + + + + + + {{block(Structure)}} that provides a connection between + {{block(Component)}} entities. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of a manufacturing process being + executed on a piece of equipment. + + + + + + + + + + abstract {{block(Component)}} composed of a manufacturing process being + executed on a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Example + + + + + + + + + + Example + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(System)}} that evacuates gases and liquids from an enclosed and + sealed space to a controlled negative pressure or a molecular density + below the prevailing atmospheric level. + + + + + + + + + + {{block(System)}} that evacuates gases and liquids from an enclosed and + sealed space to a controlled negative pressure or a molecular density + below the prevailing atmospheric level. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of a {{term(part)}} being + processed by a piece of equipment. + + + + + + + + + + abstract {{block(Component)}} composed of a {{term(part)}} being + processed by a piece of equipment. + + + + + + + {{block(Component)}} that physically prohibits a {{block(Device)}} or + {{block(Component)}} from opening or operating. + + + + + + + + + + {{block(Component)}} that physically prohibits a {{block(Device)}} or + {{block(Component)}} from opening or operating. + + + + + + + {{block(Component)}} that provides an axis of rotation for the purpose + of rapidly rotating a part or a tool to provide sufficient surface speed + for cutting operations. {{block(Spindle)}} was **DEPRECATED** in + *MTConnect Version 1.1* and was replaced by {{block(RotaryMode)}}. + + + + + + + + + + {{block(Component)}} that provides an axis of rotation for the purpose + of rapidly rotating a part or a tool to provide sufficient surface speed + for cutting operations. {{block(Spindle)}} was **DEPRECATED** in + *MTConnect Version 1.1* and was replaced by {{block(RotaryMode)}}. + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + temperature. {{block(Thermostat)}} was **DEPRECATED** in *MTConnect + Version 1.2* and was replaced by {{block(Temperature)}}. + + + + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + temperature. {{block(Thermostat)}} was **DEPRECATED** in *MTConnect + Version 1.2* and was replaced by {{block(Temperature)}}. + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + the amount and/or frequency of vibration within a system. + {{block(Vibration)}} was **DEPRECATED** in *MTConnect Version 1.2* and + was replaced by {{block(Displacement)}}, {{block(Frequency)}} etc. + + + + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + the amount and/or frequency of vibration within a system. + {{block(Vibration)}} was **DEPRECATED** in *MTConnect Version 1.2* and + was replaced by {{block(Displacement)}}, {{block(Frequency)}} etc. + + + + + + + leaf {{block(Component)}} composed of a mechanism that holds a part or + stock material in place. + + + + + + + + + + leaf {{block(Component)}} composed of a mechanism that holds a part or + stock material in place. + + + + + + + leaf {{block(Component)}} that produces a current of air. + + + + + + + + + + leaf {{block(Component)}} that produces a current of air. + + + + + + + leaf {{block(Component)}} that flattens or spreading materials. + + + + + + + + + + leaf {{block(Component)}} that flattens or spreading materials. + + + + + + + leaf {{block(Component)}} composed of a mechanism or wheel that turns in + a frame or block and serves to change the direction of or to transmit + force. + + + + + + + + + + leaf {{block(Component)}} composed of a mechanism or wheel that turns in + a frame or block and serves to change the direction of or to transmit + force. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer from a {{block(ToolMagazine)}} to {{term(spindle)}} or + {{block(Turret)}}. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer from a {{block(ToolMagazine)}} to {{term(spindle)}} or + {{block(Turret)}}. + + + + + + + leaf {{block(Component)}} that provides power to electric mechanisms. + + + + + + + + + + leaf {{block(Component)}} that provides power to electric mechanisms. + + + + + + + leaf {{block(Component)}} that allows material to flow for the purpose + of drainage from, for example, a vessel or tank. + + + + + + + + + + leaf {{block(Component)}} that allows material to flow for the purpose + of drainage from, for example, a vessel or tank. + + + + + + + leaf {{block(Component)}} composed of a mechanical structure that + transforms rotary motion into linear motion. + + + + + + + + + + leaf {{block(Component)}} composed of a mechanical structure that + transforms rotary motion into linear motion. + + + + + + + leaf {{block(Component)}} composed of a pump or other mechanism that + reduces volume and increases pressure of gases in order to condense the + gases to drive pneumatically powered pieces of equipment. + + + + + + + + + + leaf {{block(Component)}} composed of a pump or other mechanism that + reduces volume and increases pressure of gases in order to condense the + gases to drive pneumatically powered pieces of equipment. + + + + + + + leaf {{block(Component)}} composed of an inclined channel that conveys + material. + + + + + + + + + + leaf {{block(Component)}} composed of an inclined channel that conveys + material. + + + + + + + leaf {{block(Component)}} that turns on or off an electric current or + makes or breaks a circuit. + + + + + + + + + + leaf {{block(Component)}} that turns on or off an electric current or + makes or breaks a circuit. + + + + + + + leaf {{block(Component)}} that provides or applies a stretch or strain + to another mechanism. + + + + + + + + + + leaf {{block(Component)}} that provides or applies a stretch or strain + to another mechanism. + + + + + + + leaf {{block(Component)}} composed of $$H_2 O$$. + + + + + + + + + + leaf {{block(Component)}} composed of $$H_2 O$$. + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + leaf {{block(Component)}} that provides a signal or measured value. + + + + + + + + + + leaf {{block(Component)}} that provides a signal or measured value. + + + + + + + leaf {{block(Component)}} composed of a heat exchange system that uses a + fluid to transfer heat to the atmosphere. + + + + + + + + + + leaf {{block(Component)}} composed of a heat exchange system that uses a + fluid to transfer heat to the atmosphere. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + to be removed from a {{block(ToolMagazine)}} or {{block(Turret)}} to a + location outside of the piece of equipment. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + to be removed from a {{block(ToolMagazine)}} or {{block(Turret)}} to a + location outside of the piece of equipment. + + + + + + + leaf {{block(Component)}} that holds a part, stock material, or any + other item in place. + + + + + + + + + + leaf {{block(Component)}} that holds a part, stock material, or any + other item in place. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer to a {{block(ToolMagazine)}} or {{block(Turret)}} from + outside of the piece of equipment. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer to a {{block(ToolMagazine)}} or {{block(Turret)}} from + outside of the piece of equipment. + + + + + + + leaf {{block(Component)}} that slows or stops a moving object by the + absorption or transfer of the energy of momentum, usually by means of + friction, electrical force, or magnetic force. + + + + + + + + + + leaf {{block(Component)}} that slows or stops a moving object by the + absorption or transfer of the energy of momentum, usually by means of + friction, electrical force, or magnetic force. + + + + + + + leaf {{block(Component)}} composed of a storage or mounting location for + a tool associated with a {{block(Turret)}}, {{block(GangToolBar)}}, or + {{block(ToolRack)}}. + + + + + + + + + + leaf {{block(Component)}} composed of a storage or mounting location for + a tool associated with a {{block(Turret)}}, {{block(GangToolBar)}}, or + {{block(ToolRack)}}. + + + + + + + leaf {{block(Component)}} composed of a chamber or bin in which + materials are stored temporarily, typically being filled through the top + and dispensed through the bottom. + + + + + + + + + + leaf {{block(Component)}} composed of a chamber or bin in which + materials are stored temporarily, typically being filled through the top + and dispensed through the bottom. + + + + + + + leaf {{block(Component)}} composed of an endless flexible band that + transmits motion for a piece of equipment or conveys materials and + objects. + + + + + + + + + + leaf {{block(Component)}} composed of an endless flexible band that + transmits motion for a piece of equipment or conveys materials and + objects. + + + + + + + leaf {{block(Component)}} that physically moves a tool from one location + to another. + + + + + + + + + + leaf {{block(Component)}} that physically moves a tool from one location + to another. + + + + + + + leaf {{block(Component)}} composed of a rotary storage unit for + material. + + + + + + + + + + leaf {{block(Component)}} composed of a rotary storage unit for + material. + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + been removed from {{term(spindle)}} or {{block(Turret)}} and awaiting + for return to a {{block(ToolMagazine)}}. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + been removed from {{term(spindle)}} or {{block(Turret)}} and awaiting + for return to a {{block(ToolMagazine)}}. + + + + + + + leaf {{block(Component)}} composed of interconnected series of objects + that band together and are used to transmit motion for a piece of + equipment or to convey materials and objects. + + + + + + + + + + leaf {{block(Component)}} composed of interconnected series of objects + that band together and are used to transmit motion for a piece of + equipment or to convey materials and objects. + + + + + + + leaf {{block(Component)}} composed of an electronic component or circuit + that amplifies power, electric current, or voltage. + + + + + + + + + + leaf {{block(Component)}} composed of an electronic component or circuit + that amplifies power, electric current, or voltage. + + + + + + + leaf {{block(Component)}} generally composed of an open container. + + + + + + + + + + leaf {{block(Component)}} generally composed of an open container. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is no + longer usable for removal from a {{block(ToolMagazine)}} or + {{block(Turret)}}. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is no + longer usable for removal from a {{block(ToolMagazine)}} or + {{block(Turret)}}. + + + + + + + leaf {{block(Component)}} composed of a viscous liquid. + + + + + + + + + + leaf {{block(Component)}} composed of a viscous liquid. + + + + + + + leaf {{block(Component)}} composed of a surface for holding an object or + material. + + + + + + + + + + leaf {{block(Component)}} composed of a surface for holding an object or + material. + + + + + + + leaf {{block(Component)}} that breaks material into smaller pieces. + + + + + + + + + + leaf {{block(Component)}} that breaks material into smaller pieces. + + + + + + + leaf {{block(Component)}} that halts or controls the flow of a liquid, + gas, or other material through a passage, pipe, inlet, or outlet. + + + + + + + + + + leaf {{block(Component)}} that halts or controls the flow of a liquid, + gas, or other material through a passage, pipe, inlet, or outlet. + + + + + + + leaf {{block(Component)}} composed of a tool storage location associated + with a {{block(ToolMagazine)}} or {{block(AutomaticToolChanger)}}. + + + + + + + + + + leaf {{block(Component)}} composed of a tool storage location associated + with a {{block(ToolMagazine)}} or {{block(AutomaticToolChanger)}}. + + + + + + + leaf {{block(Component)}} that transforms electric energy from a source + to a secondary circuit. + + + + + + + + + + leaf {{block(Component)}} that transforms electric energy from a source + to a secondary circuit. + + + + + + + leaf {{block(Component)}} that emits a type of radiation. + + + + + + + + + + leaf {{block(Component)}} that emits a type of radiation. + + + + + + + leaf {{block(Component)}} generally composed of an enclosed container. + + + + + + + + + + leaf {{block(Component)}} generally composed of an enclosed container. + + + + + + + leaf {{block(Component)}} that measures position. + + + + + + + + + + leaf {{block(Component)}} that measures position. + + + + + + + leaf {{block(Component)}} composed of one or more cells in which + chemical energy is converted into electricity and used as a source of + power. + + + + + + + + + + leaf {{block(Component)}} composed of one or more cells in which + chemical energy is converted into electricity and used as a source of + power. + + + + + + + leaf {{block(Component)}} that interrupts an electric circuit. + + + + + + + + + + leaf {{block(Component)}} that interrupts an electric circuit. + + + + + + + leaf {{block(Component)}} that converts electrical, pneumatic, or + hydraulic energy into mechanical energy. + + + + + + + + + + leaf {{block(Component)}} that converts electrical, pneumatic, or + hydraulic energy into mechanical energy. + + + + + + + leaf {{block(Component)}} that dispenses liquid or powered materials. + + + + + + + + + + leaf {{block(Component)}} that dispenses liquid or powered materials. + + + + + + + leaf {{block(Component)}} composed of an electromechanical actuator that + produces deflection of a beam of light or energy in response to electric + current through its coil in a magnetic field. + + + + + + + + + + leaf {{block(Component)}} composed of an electromechanical actuator that + produces deflection of a beam of light or energy in response to electric + current through its coil in a magnetic field. + + + + + + + leaf {{block(Component)}} that raises, drives, exhausts, or compresses + fluids or gases by means of a piston, plunger, or set of rotating vanes. + + + + + + + + + + leaf {{block(Component)}} that raises, drives, exhausts, or compresses + fluids or gases by means of a piston, plunger, or set of rotating vanes. + + + + + + + leaf {{block(Component)}} that strengthens, support, or fastens objects + in place. + + + + + + + + + + leaf {{block(Component)}} that strengthens, support, or fastens objects + in place. + + + + + + + leaf {{block(Component)}} that measures linear motion or position. + **DEPRECATION WARNING** : May be deprecated in the future. Recommend + using {{block(Encoder)}}. + + + + + + + + + + leaf {{block(Component)}} that measures linear motion or position. + **DEPRECATION WARNING** : May be deprecated in the future. Recommend + using {{block(Encoder)}}. + + + + + + + leaf {{block(Component)}} composed of an object or material on which a + form of work is performed. + + + + + + + + + + leaf {{block(Component)}} composed of an object or material on which a + form of work is performed. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Component)}} that provides information related to an individual + {{term(feature)}}. + + + + + + + + + + {{block(Component)}} that provides information related to an individual + {{term(feature)}}. + + + + + + + system that circulates air or regulates airflow without altering + temperature or humidity. + + + + + + + + + + system that circulates air or regulates airflow without altering + temperature or humidity. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Structure)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Structure)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Interface)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Interface)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Auxiliary)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Auxiliary)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(System)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(System)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Adapter)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Adapter)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Resource)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Resource)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Component + Types::Axis)}} types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Component + Types::Axis)}} types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Process)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Process)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Part)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Part)}} + types. + + + + + + + {{block(Resources)}} that {{termplural(organize)}} {{block(Material)}} + types. + + + + + + + + + + {{block(Resources)}} that {{termplural(organize)}} {{block(Material)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Controller)}} + entities. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Controller)}} + entities. + + + + + + + Compositions Model + + + + + + + Description + + + + + + + + + Extended tyoe for The vocab for the type of composition + + + + + + + + + + The vocab for the type of composition + + + + + + + {{block(Composition)}} composed of a mechanism that moves or + controls a mechanical part of a piece of equipment. It takes energy + usually provided by air, electric current, or liquid and converts + the energy into some kind of motion. + + + + + + + {{block(Composition)}} composed of an electronic component or + circuit that amplifies power, electric current, or voltage. + + + + + + + {{block(Composition)}} composed of a mechanical structure that + transforms rotary motion into linear motion. + + + + + + + {{block(Composition)}} composed of an endless flexible band that + transmits motion for a piece of equipment or conveys materials and + objects. + + + + + + + {{block(Composition)}} composed of a mechanism that slows down or + stops a moving object by the absorption or transfer of the energy of + momentum, usually by means of friction, electrical force, or + magnetic force. + + + + + + + {{block(Composition)}} composed of an interconnected series of + objects that band together and transmit motion for a piece of + equipment or to convey materials and objects. + + + + + + + {{block(Composition)}} composed of a mechanism that breaks material + into smaller pieces. + + + + + + + {{block(Composition)}} composed of a mechanism that holds a part, + stock material, or any other item in place. + + + + + + + {{block(Composition)}} composed of an inclined channel that conveys + material. + + + + + + + {{block(Composition)}} composed of a mechanism that interrupts an + electric circuit. + + + + + + + {{block(Composition)}} composed of a mechanism that strengthens, + supports, or fastens objects in place. + + + + + + + {{block(Composition)}} composed of a pump or other mechanism that + reduces volume and increases pressure of gases in order to condense + the gases to drive pneumatically powered pieces of equipment. + + + + + + + {{block(Composition)}} composed of a mechanical mechanism or closure + that covers a physical access portal into a piece of equipment + allowing or restricting access to other parts of the equipment. + + + + + + + {{block(Composition)}} composed of a mechanism that allows material + to flow for the purpose of drainage from, for example, a vessel or + tank. + + + + + + + {{block(Composition)}} composed of a mechanism that measures rotary + position. + + + + + + + {{block(Composition)}} composed of a mechanism that emits a type of + radiation. + + + + + + + {{block(Composition)}} composed of a mechanism that dispenses liquid + or powered materials. + + + + + + + {{block(Composition)}} composed of a mechanism that produces a + current of air. + + + + + + + {{block(Composition)}} composed of a substance or structure that + allows liquids or gases to pass through to remove suspended + impurities or to recover solids. + + + + + + + {{block(Composition)}} composed of an electromechanical actuator + that produces deflection of a beam of light or energy in response to + electric current through its coil in a magnetic field. + + + + + + + {{block(Composition)}} composed of a mechanism that holds a part, + stock material, or any other item in place. + + + + + + + {{block(Composition)}} composed of a chamber or bin that stores + materials temporarily, typically being filled through the top and + dispensed through the bottom. + + + + + + + {{block(Composition)}} composed of a mechanism that measures linear + motion or position. + + + + + + + {{block(Composition)}} composed of a mechanism that converts + electrical, pneumatic, or hydraulic energy into mechanical energy. + + + + + + + {{block(Composition)}} composed of a viscous liquid. + + + + + + + {{block(Composition)}} composed of a unit that provides power to + electric mechanisms. + + + + + + + {{block(Composition)}} composed of a mechanism or wheel that turns + in a frame or block and serves to change the direction of or to + transmit force. + + + + + + + {{block(Composition)}} composed of an apparatus that raises, drives, + exhausts, or compresses fluids or gases by means of a piston, + plunger, or set of rotating vanes. + + + + + + + {{block(Composition)}} composed of a rotary storage unit for + material. + + + + + + + {{block(Composition)}} composed of a mechanism that provides a + signal or measured value. + + + + + + + {{block(Composition)}} composed of a mechanism that flattens or + spreads materials. + + + + + + + {{block(Composition)}} composed of one or more cells that converts + chemical energy to electricity and serves as a source of power. + + + + + + + {{block(Composition)}} composed of a mechanism that turns on or off + an electric current or makes or breaks a circuit. + + + + + + + {{block(Composition)}} composed of a surface that holds an object or + material. + + + + + + + {{block(Composition)}} composed of a receptacle or container that + holds material. + + + + + + + {{block(Composition)}} composed of a mechanism that provides or + applies a stretch or strain to another mechanism. + + + + + + + {{block(Composition)}} composed of a mechanism that transforms + electric energy from a source to a secondary circuit. + + + + + + + {{block(Composition)}} composed of a mechanism that halts or + controls the flow of a liquid, gas, or other material through a + passage, pipe, inlet, or outlet. + + + + + + + {{block(Composition)}} composed of a container for liquid or + powdered materials. + + + + + + + {{block(Composition)}} composed of a fluid. + + + + + + + {{block(Composition)}} composed of a string like piece or filament + of relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + {{block(Composition)}} composed of an object or material on which a + form of work is performed. + + + + + + + {{block(Composition)}} composed of a heat exchange system that uses + a fluid to transfer heat to the atmosphere. + + + + + + + {{block(Composition)}} composed of a tool storage location + associated with a {{block(ToolMagazine)}} or + {{block(AutomaticToolChanger)}}. + + + + + + + {{block(Composition)}} composed of a storage or mounting location + for a tool associated with a {{block(Turret)}}, + {{block(GangToolBar)}}, or {{block(ToolRack)}}. + + + + + + + {{block(Composition)}} composed of a mechanism that physically moves + a tool from one location to another. + + + + + + + {{block(Pot)}} for a tool awaiting transfer from a + {{block(ToolMagazine)}} to {{term(spindle)}} or {{block(Turret)}}. + + + + + + + {{block(Pot)}} for a tool removed from {{term(spindle)}} or + {{block(Turret)}} and awaiting for return to a + {{block(ToolMagazine)}}. + + + + + + + {{block(Pot)}} for a tool awaiting transfer to a + {{block(ToolMagazine)}} or {{block(Turret)}} from outside of the + piece of equipment. + + + + + + + {{block(Pot)}} for a tool to be removed from a + {{block(ToolMagazine)}} or {{block(Turret)}} to a location outside + of the piece of equipment. + + + + + + + {{block(Pot)}} for a tool that is no longer usable for removal from + a {{block(ToolMagazine)}} or {{block(Turret)}}. + + + + + + + + + The vocab for the type of composition + + + + + + + + Description + + + + + + + See {{sect(Description)}}. + + + + + + + technical information about an entity describing its physical + layout, functional characteristics, and relationships with other + entities. + + + + + + + + unique identifier for the power source. + + + + + + + The composition's universally unique id. + + + + + + + identifier of the maintenance activity. + + + + + + + The type of composition + + + + + + + + A reference to an identifier + + + + + + + + References Model + + + + + + + + + + Description + + + + + + A reference to an id in the MTConnectDevices model + + + + + + + identifier of the maintenance activity. + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Abstract configuration + + + + + + + Abstract configuration + + + + + + + The configuration data associated with this component. + + + + + + + + + + The time the calibration was preformed + + + + + + + + The time the next calibration should be preformed + + + + + + + + The initials of the person doing the calibration + + + + + + + + The firmware version of this sensor + + + + + + + + The channel number + + + + + + + + See {{block(SensorConfiguration)}}. + + + + + + + + + Version number for the sensor unit as specified by the + manufacturer. + + + + + + + Date upon which the {{term(sensor unit)}} was last calibrated to + the {{term(sensor element)}}. + + + + + + + Date upon which the {{term(sensor element)}} is next scheduled + to be calibrated with the {{term(sensor unit)}}. + + + + + + + The initials of the person verifying the validity of the + calibration data. + + + + + + + Any additional properties + + + + + + + {{block(Channels)}} groups one or more {{block(Channel)}} + entities. See {{block(Channel)}}. + + + + + + + + + + + See {{block(SensorConfiguration)}}. + + + + + + + {{block(Channels)}} groups one or more {{block(Channel)}} entities. See + {{block(Channel)}}. + + + + + + + Description + + + + + + + + + Description + + + + + + + See {{sect(Description)}}. + + + + + + + Date upon which the {{term(sensor unit)}} was last calibrated to the + {{term(sensor element)}}. + + + + + + + Date upon which the {{term(sensor element)}} is next scheduled to be + calibrated with the {{term(sensor unit)}}. + + + + + + + The initials of the person verifying the validity of the calibration + data. + + + + + + + + The channel id + + + + + + + identifier of the maintenance activity. + + + + + + + + The peak value + + + + + + + + {{block(Specifications)}} groups one or more {{block(Specification)}} + entities. See {{package(Specifications)}}. + + + + + + + + + + + + + + {{block(Specifications)}} groups one or more {{block(Specification)}} + entities. See {{package(Specifications)}}. + + + + + + + Extended tyoe for A reference to the creator of the Specification + + + + + + + + + + A reference to the creator of the Specification + + + + + + + The manufacturer of a piece of equipment or component. + + + + + + + The owner or implementer of a piece of equipment or component. + + + + + + + + + A reference to the creator of the Specification + + + + + + + + A specification + + + + + + The identity of the Specificaiton + + + + + + + The type of measurement + + + + + + + A reference to the creator of the Specification + + + + + + + The type of measurement + + + + + + + identifier of the maintenance activity. + + + + + + + The optional data item identifier + + + + + + + The optional composition identifier + + + + + + + The optional coordinate system identifier + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + A specification + + + + + + + design characteristics for a piece of equipment. + + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may + be required. + + + + + + + lower boundary indicating increased concern and supervision may + be required. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + + + design characteristics for a piece of equipment. + + + + + + + The limit of a constraint + + + + + + + + + + The limit of a constraint + + + + + + + numeric upper constraint. + + + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + numeric target or expected value. + + + + + + + upper conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + + + + upper conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + lower conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + + + + lower conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + {{block(Specification)}} that provides information used to assess the + conformance of a variable to process requirements. + + + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + + + + + {{block(Specification)}} that provides information used to assess the + conformance of a variable to process requirements. + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + numeric target or expected value. + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + numeric target or expected value. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + The list of possible association types + + + + + + + The related entity is a parent + + + + + + + The related entity is a child + + + + + + + The related entity is a peer + + + + + + + + + device relationships + + + + + + + a system + + + + + + + an auxiliary + + + + + + + + + The criticality + + + + + + + critical + + + + + + + Not critical + + + + + + + + + A relationship between this component and something else + + + + + + The relationship identifier + + + + + + + identifier of the maintenance activity. + + + + + + + The assciation type + + + + + + + Criticality + + + + + + + + A relationship between this component and something else + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two components within a piece of equipment that function + independently but together perform a capability or service within a + piece of equipment. + + + + + + + + A reference to the device uuid + + + + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two components within a piece of equipment that function + independently but together perform a capability or service within a + piece of equipment. + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two pieces of equipment that function independently but together + perform a manufacturing operation. + + + + + + + + A reference to the device uuid + + + + + + + The type of relatiship + + + + + + + {{term(URL)}} giving the location of the image file. + + + + + + + Description + + + + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two pieces of equipment that function independently but together + perform a manufacturing operation. + + + + + + + The type of coordinate system + + + + + + + The world + + + + + + + The base of the manipulator chain + + + + + + + The object + + + + + + + The current task + + + + + + + The last joint in the chain + + + + + + + The tool's coord + + + + + + + The platform + + + + + + + For machine tools, the coordinate system in the work area + + + + + + + For machine tools, the coordinate system in the work area + + + + + + + + + {{block(CoordinateSystems)}} groups one or more + {{block(CoordinateSystem)}} entities. See + {{package(CoordinateSystems)}}. + + + + + + + + + Description + + + + + + + + + + + {{block(CoordinateSystems)}} groups one or more + {{block(CoordinateSystem)}} entities. See + {{package(CoordinateSystems)}}. + + + + + + + Description + + + + + + + See {{sect(Origin)}}. + + + + + + + See {{sect(Transformation)}}. + + + + + + + + The coordinate system identifier + + + + + + + identifier of the maintenance activity. + + + + + + + The optional name of the coordinate system + + + + + + + The parent of the coordinate system + + + + + + + The coordinate system type + + + + + + + uuid + + + + + + + + See {{sect(Origin)}}. + + + + + + + + + + See {{sect(Transformation)}}. + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + The types of motion + + + + + + + Rotates around an axis with a fixed range of motion + + + + + + + Revolves around an axis with a continuous range of motion + + + + + + + Sliding linear motion along an axis with a fixed range of motion + + + + + + + The axis does not move. + + + + + + + + + The actuation of this component + + + + + + + The movement is initiated by the component. + + + + + + + The motion is computed and is used for expressing an imaginary + movement. + + + + + + + There is no actuation of this Axis. + + + + + + + + + The unit vector along which the motion occurs + + + + + + + + + + The description of the motion + + + + + + + Any elements + + + + + + + + + See {{sect(Motion)}}. + + + + + + + + + See {{sect(Description)}}. + + + + + + + + See {{sect(Origin)}}. + + + + + + + See {{sect(Transformation)}}. + + + + + + + + See {{sect(Axis)}}. + + + + + + + + The coordinate system identifier + + + + + + + The parent of the coordinate system + + + + + + + The identifier of the coordinate system that this motion is + relative to + + + + + + + The motion type + + + + + + + The actuation method + + + + + + + + + + See {{sect(Motion)}}. + + + + + + + A reference to another model + + + + + + + + A reference to an item in a model + + + + + + + + See {{sect(SolidModel)}}. + + + + + + + + + See {{sect(Transformation)}}. + + + + + + + See {{sect(Scale)}}. + + + + + + + + the unique identifier for this entity within the MTConnectDevices + document + + + + + + + The associated model file if an item reference is used + + + + + + + {{term(URL)}} giving the location of the image file. + + + + + + + Description + + + + + + + The reference to the item within the model within the related + geometry. A modelIdRef MUST be given. + + + + + + + The format of the referenced document + + + + + + + The identifier of the coordinate system that this motion is + relative to + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The units as expressed by the machine + + + + + + + + + + See {{sect(SolidModel)}}. + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + The unit vector to scale the model + + + + + + + + + + Extended tyoe for Solid model media types + + + + + + + + + + Solid model media types + + + + + + + ISO 10303 STEP AP203 or AP242 format + + + + + + + Stereolithography file format + + + + + + + Geometry Description Markup Language + + + + + + + Wavefront OBJ file format + + + + + + + ISO 17506 + + + + + + + Initial Graphics Exchange Specification + + + + + + + Autodesk file format + + + + + + + Dassault file format + + + + + + + Parasolid XT Siemens data interchange format + + + + + + + + + Solid model media types + + + + + + + + url of an image file + + + + + + + + mime type + + + + + + + + This section provides semantic information for the {{block(ImageFile)}} + entity. + + + + + + + + + reference to a file containing an image of the + {{block(Component)}}. + + + + + + + + + + + This section provides semantic information for the {{block(ImageFile)}} + entity. + + + + + + + reference to a file containing an image of the {{block(Component)}}. + + + + + + + + identifier + + + + + + + identifier of the maintenance activity. + + + + + + + URL of image file + + + + + + + mime type of image file + + + + + + + + + + The item's reference to the component + + + + + + + + The name of the power source + + + + + + + + The order of precedence for a given power source + + + + + + + + The type of power source + + + + + + + main or principle + + + + + + + alternate or not primary + + + + + + + held near at hand and ready for use and is uninterruptible + + + + + + + + + This section provides semantic information for the + {{block(PowerSource)}} entity. ![PowerSources](figures/PowerSources.png + "PowerSources"){: width="0.8"} + + + + + + + + + potential energy sources for the {{block(Component)}}. + + + + + + + + + + + This section provides semantic information for the + {{block(PowerSource)}} entity. ![PowerSources](figures/PowerSources.png + "PowerSources"){: width="0.8"} + + + + + + + potential energy sources for the {{block(Component)}}. + + + + + + + optional precedence for a given power source + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST NOT** + be used in conjunction with any other {{block(Constraint)}} + elements. + + + + + + + + type of power source + + + + + + + identifier + + + + + + + reference to component + + + + + + + + The interval between adjacent sampleing of data + + + + + + + + The frequency a measurement is sampled + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + An idref to the component id + + + + + + + + An idref to the data item id + + + + + + + + The item's reference to the data item or specificatiton + + + + + + + + The name of a related component + + + + + + + + The id reference for the coordinate system associated with this data + item + + + + + + + + An discrete event + + + + + + + + The description of a data item, can be free form text or elements + + + + + + + Any elements + + + + + + + + + The minimum limit on the change in a value + + + + + + + + The measurement sampling type + + + + + + + An event represents a change in state occurs at a point in time. + Note: An event does not occur at predefined frequencies. + + + + + + + A sample is a data point for continuous data items, that is, the + value of a data item at a point in time. + + + + + + + The condition of the device + + + + + + + + + The multiplier for the native value. Conversion divides by this value + + + + + + + + Description + + + + + + + series of sampled data. The data is reported for a specified number + of samples and each sample is reported with a fixed period. + + + + + + + measured value of the sample data. If no + {{property(DataItem::representation)}} is specified for a data item, + the {{property(DataItem::representation)}} **MUST** be determined to + be `VALUE`. + + + + + + + reported value(s) are represented as a set of {{termplural(key-value + pair)}}. Each reported value in the {{term(data set)}} **MUST** have + a unique key. + + + + + + + **DEPRECATED** as {{property(DataItem::representation)}} type in + *MTConnect Version 1.5*. Replaced by the + {{property(DataItem::discrete)}}. + + + + + + + two dimensional set of {{termplural(key-value pair)}} where the + {{block(Entry)}} represents a row, and the value is a set of + {{term(key-value pair)}} {{block(Cell)}} elements. A {{term(table)}} + follows the same behavior as the {{term(data set)}} for change + tracking, clearing, and history. When an {{block(Entry)}} changes, + all {{block(Cell)}} elements update as a single unit following the + behavior of a {{term(data set)}}. > Note: It is best to use + {{block(Variable)}} if the {{block(Cell)}} entities represent + multiple semantic types. Each {{block(Entry)}} in the + {{term(table)}} **MUST** have a unique key. Each {{block(Cell)}} of + each {{block(Entry)}} in the {{term(table)}} **MUST** have a unique + key. See {{block(Representation)}} in {{package(Observation + Information Model)}}, for a description of {{block(Entry)}} and + {{block(Cell)}} elements. + + + + + + + + + The type of filter + + + + + + + new value **MUST NOT** be reported for a data item unless the + measured value has changed from the last reported value by at least + the delta given as the value of this element. The value of + {{block(Filter)}} **MUST** be an absolute value using the same units + as the reported data. + + + + + + + data reported for a data item is provided on a periodic basis. The + `PERIOD` for reporting data is defined in the value of the + {{block(Filter)}}. The value of {{block(Filter)}} **MUST** be an + absolute value reported in seconds representing the time between + reported samples of the value of the data item. + + + + + + + + + + + + + + information reported about a piece of equipment. + + + + + + + + + information reported about a piece of equipment. + + + + + + + identifies the {{block(Component)}}, {{block(DataItem)}}, or + {{block(Composition)}} from which a measured value originates. + + + + + + + {{termplural(organize)}} a set of expected values that can be + reported for a {{block(DataItem)}}. + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + starting value for a {{block(DataItem)}} as well as the value to be + set for the {{block(DataItem)}} after a reset event. + + + + + + + type of event that may cause a reset to occur. + + + + + + + defines the meaning of {{block(Entry)}} and {{block(Cell)}} entities + when the associated {{property(DataItem::representation)}} is either + `DATA_SET` or `TABLE`. + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + unique identifier for the power source. + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + The statistical operation on this data + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The units as expressed by the machine + + + + + + + The units as expressed by the machine + + + + + + + The category of the data item + + + + + + + Description + + + + + + + The coordinate system reference to a particular coordinate system + + + + + + + The optional composition identifier + + + + + + + Used as the default sample rate for waveforms + + + + + + + Description + + + + + + + The number of significant digits for this data item + + + + + + + Description + + + + + + + + A set of limits for a data item + + + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST + NOT** be used in conjunction with any other + {{block(Constraint)}} elements. + + + + + + + + + numeric lower constraint. + + + + + + + numeric upper constraint. + + + + + + + numeric target or expected value. + + + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + A starting point for a data item + + + + + + + + + + The value element + + + + + + + + + + The filter for the data item + + + + + + + + The type of filter, ABSOLUTE or PERCENT + + + + + + + + + + A native data source + + + + + + + + The optional data item within the source component that provides + the underlying data + + + + + + + The component that is collecting the data associated with this + data item + + + + + + + The optional composition identifier for the source of this data + item + + + + + + + + + + The DataItem Definition + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + + + + unique key + + + + + + + The type of measurement + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + + {{block(CellDefinitions)}} groups one or more {{block(CellDefinition)}} + entities. See {{sect(CellDefinition)}}. + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + + + + Organizes DataItemRelationship and SpecificationRelationship + + + + + + + + + + Description + + + + + + identifier of the maintenance activity. + + + + + + + A reference to the related DataItem id. + + + + + + + + Description + + + + + + + How the data items are related + + + + + + + A reference to a DataItem that associates the values with an + external entity + + + + + + + The referenced DataItem provides the id of the effective Coordinate + System + + + + + + + The referenced DataItem provides process limits. + + + + + + + The referenced DataItem provides the observed values. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + How the data items are related + + + + + + + The referenced DataItem provides process limits. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + \ No newline at end of file diff --git a/schemas/MTConnectDevices_2.4_1.0.xsd b/schemas/MTConnectDevices_2.4_1.0.xsd new file mode 100644 index 00000000..ecb7cdcc --- /dev/null +++ b/schemas/MTConnectDevices_2.4_1.0.xsd @@ -0,0 +1,10303 @@ + + + + + + + + root entity of an {{term(MTConnectDevices Response Document)}} that + contains the {{term(Device Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectDevices](figures/MTConnectDevices.png + "MTConnectDevices"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectDevices)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + The number of assets + + + + + + + + + + + {{block(AssetCounts)}} groups {{block(AssetCount)}} entities. + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + The type of asset + + + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + {{block(AssetCounts)}} groups {{block(AssetCount)}} entities. + + + + + + + + + The size of the agent's buffer. + + + + + + + The maximum number of assets + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + root entity of an {{term(MTConnectDevices Response Document)}} that + contains the {{term(Device Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectDevices](figures/MTConnectDevices.png + "MTConnectDevices"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectDevices)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + This section provides semantic information for the {{block(Device)}} + types. + + + + + + + + + The station id for this device + + + + + + + + The ISO 841 classification for the device + + + + + + + + The model name + + + + + + + + This section provides semantic information for the {{block(Device)}} + types. + + + + + + + Description + + + + + + + Description + + + + + + + + + Description + + + + + + + See {{sect(Description)}}. + + + + + + + technical information about an entity describing its physical + layout, functional characteristics, and relationships with other + entities. + + + + + + + + + + + + {{block(Components)}} groups one or more {{block(Component)}} + entities. + + + + + + + Compositions Model + + + + + + + References Model + + + + + + + + unique identifier for the power source. + + + + + + + The device manufacturer component name + + + + + + + The rate at which the data is sampled from the component + + + + + + + DEPRECATED: The rate at which the data is sampled from the component + + + + + + + + Description + + + + + + + The descriptive information. This can be manufacturer specific + + + + + + + The content of the description can text or XML elements + + + + + + + + name of the material manufacturer. + + + + + + + The model + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + leaf {{block(Component)}} composed of a storage or mounting location + for a tool associated with a {{block(Turret)}}, + {{block(GangToolBar)}}, or {{block(ToolRack)}}. + + + + + + + + An abstract component that has an optional uuid + + + + + + + + The component's universally unique id. + + + + + + + identifier of the maintenance activity. + + + + + + + + + + An abstract component that has an optional uuid + + + + + + + {{block(Components)}} groups one or more {{block(Component)}} entities. + + + + + + + + + + Description + + + + + + + + DEPRECATED: The device's ISO-841 classification + + + + + + + The components universally unique id. This can be composed of the + manufactures id or name and the serial number. + + + + + + + identifier of the maintenance activity. + + + + + + + MTConnect version of the {{term(Device Information Model)}} used + to configure the information to be published for a piece of + equipment in an {{term(MTConnect Response Document)}}. + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of removable part(s) of a piece + of equipment that provides supplementary or extended functionality. + + + + + + + + + + abstract {{block(Component)}} composed of removable part(s) of a piece + of equipment that provides supplementary or extended functionality. + + + + + + + See {{sect(Axis)}}. + + + + + + + + + + See {{sect(Axis)}}. + + + + + + + {{block(Loader)}} that delivers bar stock to a piece of equipment. + + + + + + + + + + {{block(Loader)}} that delivers bar stock to a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(System)}} that provides distribution and management of fluids + that remove heat from a piece of equipment. + + + + + + + + + + {{block(System)}} that provides distribution and management of fluids + that remove heat from a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Component)}} that observes the surroundings of another + {{block(Component)}}. > Note: {{block(Environmental)}} **SHOULD** be + organized by {{block(Auxillaries)}}, {{block(Systems)}} or + {{block(Parts)}} depending on the relationship to the + {{block(Component)}}. + + + + + + + + + + {{block(Component)}} that observes the surroundings of another + {{block(Component)}}. > Note: {{block(Environmental)}} **SHOULD** be + organized by {{block(Auxillaries)}}, {{block(Systems)}} or + {{block(Parts)}} depending on the relationship to the + {{block(Component)}}. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(System)}} that provides movement and distribution of pressurized + liquid throughout the piece of equipment. + + + + + + + + + + {{block(System)}} that provides movement and distribution of pressurized + liquid throughout the piece of equipment. + + + + + + + {{block(Component Types::Axis)}} that provides prismatic motion along a + fixed axis. + + + + + + + + + + {{block(Component Types::Axis)}} that provides prismatic motion along a + fixed axis. + + + + + + + {{block(Auxiliary)}} that provides movement and distribution of + materials, parts, tooling, and other items to or from a piece of + equipment. + + + + + + + + + + {{block(Auxiliary)}} that provides movement and distribution of + materials, parts, tooling, and other items to or from a piece of + equipment. + + + + + + + {{block(System)}} that provides distribution and management of fluids + used to lubricate portions of the piece of equipment. + + + + + + + + + + {{block(System)}} that provides distribution and management of fluids + used to lubricate portions of the piece of equipment. + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Resource)}} composed of an individual or individuals who either + control, support, or otherwise interface with a piece of equipment. + + + + + + + + + + {{block(Resource)}} composed of an individual or individuals who either + control, support, or otherwise interface with a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Power)}} was **DEPRECATED** in *MTConnect Version 1.1* and was + replaced by {{block(Availability)}} data item type. + + + + + + + + + + {{block(Power)}} was **DEPRECATED** in *MTConnect Version 1.1* and was + replaced by {{block(Availability)}} data item type. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of material or personnel involved + in a manufacturing process. + + + + + + + + + + abstract {{block(Component)}} composed of material or personnel involved + in a manufacturing process. + + + + + + + {{block(Component Types::Axis)}} that provides rotation about a fixed + axis. + + + + + + + + + + {{block(Component Types::Axis)}} that provides rotation about a fixed + axis. + + + + + + + This section provides semantic information for the + {{block(SensorConfiguration)}} entity. {{term(sensor)}} is a unique type + of a piece of equipment. A {{term(sensor)}} is typically comprised of + two major components: a {{term(sensor unit)}} that provides signal + processing, conversion, and communications and the {{termplural(sensing + element)}} that provides a signal or measured value. The {{term(sensor + unit)}} is modeled as a {{term(lower level)}} {{block(Component)}} + called {{block(Sensor)}}. The {{term(sensing element)}} may be modeled + as a {{block(Composition)}} element of a {{block(Sensor)}} element and + the measured value would be modeled as a {{block(DataItem)}} (See + {{sect(DataItems)}} for more information on {{block(DataItem)}} + elements). Each {{term(sensor unit)}} may have multiple + {{termplural(sensing element)}}; each representing the data for a + variety of measured values. ![Sensing Element provided as a DataItem + Example](figures/Sensing%20Element%20provided%20as%20a%20DataItem%20Example.png "Sensing Element provided as a DataItem Example"){: width="0.8"} > Note: See {{lst(example-of-sensing-element-provided-as-data-item-associated-with-a-component)}} for an {{term(XML)}} example. When a {{term(sensor unit)}} is modeled as a {{block(Component)}} or as a separate piece of equipment, it may provide additional configuration information for the {{termplural(sensor element)}} and the {{term(sensor unit)}} itself. ![Sensor for Rotary Axis Example](figures/Sensor%20for%20Rotary%20Axis%20Example.png "Sensor for Rotary Axis Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides vibration measurement data for the spindle on a piece of equipment, it could be modeled as a {{block(Sensor)}} for rotary axis named `C`. See {{lst(example-of-sensor-for-rotary-axis)}} for an {{term(XML)}} example. ![Sensor unit with Sensing Elements Example](figures/Sensor%20unit%20with%20Sensing%20Elements%20Example.png "Sensor unit with Sensing Elements Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides measurement data for multiple {{block(Component)}} elements within a piece of equipment and is not associated with any particular {{block(Component)}}, it **MAY** be modeled as an independent {{block(Component)}} and the data associated with measurements are associated with their associated {{block(Component)}} entities. See {{lst(example-of-sensor-unit-with-sensing-element)}} for an {{term(XML)}} example. {{block(Configuration)}} data provides information required for maintenance and support of the sensor. When {{block(Sensor)}} represents the {{term(sensor unit)}} for multiple {{term(sensing element)}}(s), each sensing element is represented by a {{block(Channel)}}. The {{term(sensor unit)}} itself and each {{block(Channel)}} representing one {{term(sensing element)}} **MAY** have its own configuration data. ![Sensor Configuration Example](figures/Sensor%20Configuration%20Example.png "Sensor Configuration Example"){: width="0.8"} > Note: See {{lst(example-of-configuration-data-for-sensor)}} for an {{term(XML)}} example. + + + + + + + + + + This section provides semantic information for the + {{block(SensorConfiguration)}} entity. {{term(sensor)}} is a unique type + of a piece of equipment. A {{term(sensor)}} is typically comprised of + two major components: a {{term(sensor unit)}} that provides signal + processing, conversion, and communications and the {{termplural(sensing + element)}} that provides a signal or measured value. The {{term(sensor + unit)}} is modeled as a {{term(lower level)}} {{block(Component)}} + called {{block(Sensor)}}. The {{term(sensing element)}} may be modeled + as a {{block(Composition)}} element of a {{block(Sensor)}} element and + the measured value would be modeled as a {{block(DataItem)}} (See + {{sect(DataItems)}} for more information on {{block(DataItem)}} + elements). Each {{term(sensor unit)}} may have multiple + {{termplural(sensing element)}}; each representing the data for a + variety of measured values. ![Sensing Element provided as a DataItem + Example](figures/Sensing%20Element%20provided%20as%20a%20DataItem%20Example.png "Sensing Element provided as a DataItem Example"){: width="0.8"} > Note: See {{lst(example-of-sensing-element-provided-as-data-item-associated-with-a-component)}} for an {{term(XML)}} example. When a {{term(sensor unit)}} is modeled as a {{block(Component)}} or as a separate piece of equipment, it may provide additional configuration information for the {{termplural(sensor element)}} and the {{term(sensor unit)}} itself. ![Sensor for Rotary Axis Example](figures/Sensor%20for%20Rotary%20Axis%20Example.png "Sensor for Rotary Axis Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides vibration measurement data for the spindle on a piece of equipment, it could be modeled as a {{block(Sensor)}} for rotary axis named `C`. See {{lst(example-of-sensor-for-rotary-axis)}} for an {{term(XML)}} example. ![Sensor unit with Sensing Elements Example](figures/Sensor%20unit%20with%20Sensing%20Elements%20Example.png "Sensor unit with Sensing Elements Example"){: width="0.8"} > Note: If a {{block(Sensor)}} provides measurement data for multiple {{block(Component)}} elements within a piece of equipment and is not associated with any particular {{block(Component)}}, it **MAY** be modeled as an independent {{block(Component)}} and the data associated with measurements are associated with their associated {{block(Component)}} entities. See {{lst(example-of-sensor-unit-with-sensing-element)}} for an {{term(XML)}} example. {{block(Configuration)}} data provides information required for maintenance and support of the sensor. When {{block(Sensor)}} represents the {{term(sensor unit)}} for multiple {{term(sensing element)}}(s), each sensing element is represented by a {{block(Channel)}}. The {{term(sensor unit)}} itself and each {{block(Channel)}} representing one {{term(sensing element)}} **MAY** have its own configuration data. ![Sensor Configuration Example](figures/Sensor%20Configuration%20Example.png "Sensor Configuration Example"){: width="0.8"} > Note: See {{lst(example-of-configuration-data-for-sensor)}} for an {{term(XML)}} example. + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} that is permanently integrated into the + piece of equipment. + + + + + + + + + + abstract {{block(Component)}} that is permanently integrated into the + piece of equipment. + + + + + + + {{block(Auxiliary)}} that manages, positions, stores, and delivers + tooling within a piece of equipment. + + + + + + + + + + {{block(Auxiliary)}} that manages, positions, stores, and delivers + tooling within a piece of equipment. + + + + + + + {{block(Auxiliary)}} that removes manufacturing byproducts from a piece + of equipment. + + + + + + + + + + {{block(Auxiliary)}} that removes manufacturing byproducts from a piece + of equipment. + + + + + + + {{block(Component)}} composed of part(s) comprising the rigid bodies of + the piece of equipment. + + + + + + + + + + {{block(Component)}} composed of part(s) comprising the rigid bodies of + the piece of equipment. + + + + + + + {{block(Structure)}} that provides a connection between + {{block(Component)}} entities. + + + + + + + + + + {{block(Structure)}} that provides a connection between + {{block(Component)}} entities. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of a manufacturing process being + executed on a piece of equipment. + + + + + + + + + + abstract {{block(Component)}} composed of a manufacturing process being + executed on a piece of equipment. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Example + + + + + + + + + + Example + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(System)}} that evacuates gases and liquids from an enclosed and + sealed space to a controlled negative pressure or a molecular density + below the prevailing atmospheric level. + + + + + + + + + + {{block(System)}} that evacuates gases and liquids from an enclosed and + sealed space to a controlled negative pressure or a molecular density + below the prevailing atmospheric level. + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + abstract {{block(Component)}} composed of a {{term(part)}} being + processed by a piece of equipment. + + + + + + + + + + abstract {{block(Component)}} composed of a {{term(part)}} being + processed by a piece of equipment. + + + + + + + {{block(Component)}} that physically prohibits a {{block(Device)}} or + {{block(Component)}} from opening or operating. + + + + + + + + + + {{block(Component)}} that physically prohibits a {{block(Device)}} or + {{block(Component)}} from opening or operating. + + + + + + + {{block(Component)}} that provides an axis of rotation for the purpose + of rapidly rotating a part or a tool to provide sufficient surface speed + for cutting operations. {{block(Spindle)}} was **DEPRECATED** in + *MTConnect Version 1.1* and was replaced by {{block(RotaryMode)}}. + + + + + + + + + + {{block(Component)}} that provides an axis of rotation for the purpose + of rapidly rotating a part or a tool to provide sufficient surface speed + for cutting operations. {{block(Spindle)}} was **DEPRECATED** in + *MTConnect Version 1.1* and was replaced by {{block(RotaryMode)}}. + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + temperature. {{block(Thermostat)}} was **DEPRECATED** in *MTConnect + Version 1.2* and was replaced by {{block(Temperature)}}. + + + + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + temperature. {{block(Thermostat)}} was **DEPRECATED** in *MTConnect + Version 1.2* and was replaced by {{block(Temperature)}}. + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + the amount and/or frequency of vibration within a system. + {{block(Vibration)}} was **DEPRECATED** in *MTConnect Version 1.2* and + was replaced by {{block(Displacement)}}, {{block(Frequency)}} etc. + + + + + + + + + + {{block(Component)}} composed of a sensor or an instrument that measures + the amount and/or frequency of vibration within a system. + {{block(Vibration)}} was **DEPRECATED** in *MTConnect Version 1.2* and + was replaced by {{block(Displacement)}}, {{block(Frequency)}} etc. + + + + + + + leaf {{block(Component)}} composed of a mechanism that holds a part or + stock material in place. + + + + + + + + + + leaf {{block(Component)}} composed of a mechanism that holds a part or + stock material in place. + + + + + + + leaf {{block(Component)}} that produces a current of air. + + + + + + + + + + leaf {{block(Component)}} that produces a current of air. + + + + + + + leaf {{block(Component)}} that flattens or spreading materials. + + + + + + + + + + leaf {{block(Component)}} that flattens or spreading materials. + + + + + + + leaf {{block(Component)}} composed of a mechanism or wheel that turns in + a frame or block and serves to change the direction of or to transmit + force. + + + + + + + + + + leaf {{block(Component)}} composed of a mechanism or wheel that turns in + a frame or block and serves to change the direction of or to transmit + force. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer from a {{block(ToolMagazine)}} to {{term(spindle)}} or + {{block(Turret)}}. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer from a {{block(ToolMagazine)}} to {{term(spindle)}} or + {{block(Turret)}}. + + + + + + + leaf {{block(Component)}} that provides power to electric mechanisms. + + + + + + + + + + leaf {{block(Component)}} that provides power to electric mechanisms. + + + + + + + leaf {{block(Component)}} that allows material to flow for the purpose + of drainage from, for example, a vessel or tank. + + + + + + + + + + leaf {{block(Component)}} that allows material to flow for the purpose + of drainage from, for example, a vessel or tank. + + + + + + + leaf {{block(Component)}} composed of a mechanical structure that + transforms rotary motion into linear motion. + + + + + + + + + + leaf {{block(Component)}} composed of a mechanical structure that + transforms rotary motion into linear motion. + + + + + + + leaf {{block(Component)}} composed of a pump or other mechanism that + reduces volume and increases pressure of gases in order to condense the + gases to drive pneumatically powered pieces of equipment. + + + + + + + + + + leaf {{block(Component)}} composed of a pump or other mechanism that + reduces volume and increases pressure of gases in order to condense the + gases to drive pneumatically powered pieces of equipment. + + + + + + + leaf {{block(Component)}} composed of an inclined channel that conveys + material. + + + + + + + + + + leaf {{block(Component)}} composed of an inclined channel that conveys + material. + + + + + + + leaf {{block(Component)}} that turns on or off an electric current or + makes or breaks a circuit. + + + + + + + + + + leaf {{block(Component)}} that turns on or off an electric current or + makes or breaks a circuit. + + + + + + + leaf {{block(Component)}} that provides or applies a stretch or strain + to another mechanism. + + + + + + + + + + leaf {{block(Component)}} that provides or applies a stretch or strain + to another mechanism. + + + + + + + leaf {{block(Component)}} composed of $$H_2 O$$. + + + + + + + + + + leaf {{block(Component)}} composed of $$H_2 O$$. + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + leaf {{block(Component)}} that provides a signal or measured value. + + + + + + + + + + leaf {{block(Component)}} that provides a signal or measured value. + + + + + + + leaf {{block(Component)}} composed of a heat exchange system that uses a + fluid to transfer heat to the atmosphere. + + + + + + + + + + leaf {{block(Component)}} composed of a heat exchange system that uses a + fluid to transfer heat to the atmosphere. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + to be removed from a {{block(ToolMagazine)}} or {{block(Turret)}} to a + location outside of the piece of equipment. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + to be removed from a {{block(ToolMagazine)}} or {{block(Turret)}} to a + location outside of the piece of equipment. + + + + + + + leaf {{block(Component)}} that holds a part, stock material, or any + other item in place. + + + + + + + + + + leaf {{block(Component)}} that holds a part, stock material, or any + other item in place. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer to a {{block(ToolMagazine)}} or {{block(Turret)}} from + outside of the piece of equipment. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is + awaiting transfer to a {{block(ToolMagazine)}} or {{block(Turret)}} from + outside of the piece of equipment. + + + + + + + leaf {{block(Component)}} that slows or stops a moving object by the + absorption or transfer of the energy of momentum, usually by means of + friction, electrical force, or magnetic force. + + + + + + + + + + leaf {{block(Component)}} that slows or stops a moving object by the + absorption or transfer of the energy of momentum, usually by means of + friction, electrical force, or magnetic force. + + + + + + + leaf {{block(Component)}} composed of a storage or mounting location for + a tool associated with a {{block(Turret)}}, {{block(GangToolBar)}}, or + {{block(ToolRack)}}. + + + + + + + + + + leaf {{block(Component)}} composed of a storage or mounting location for + a tool associated with a {{block(Turret)}}, {{block(GangToolBar)}}, or + {{block(ToolRack)}}. + + + + + + + leaf {{block(Component)}} composed of a chamber or bin in which + materials are stored temporarily, typically being filled through the top + and dispensed through the bottom. + + + + + + + + + + leaf {{block(Component)}} composed of a chamber or bin in which + materials are stored temporarily, typically being filled through the top + and dispensed through the bottom. + + + + + + + leaf {{block(Component)}} composed of an endless flexible band that + transmits motion for a piece of equipment or conveys materials and + objects. + + + + + + + + + + leaf {{block(Component)}} composed of an endless flexible band that + transmits motion for a piece of equipment or conveys materials and + objects. + + + + + + + leaf {{block(Component)}} that physically moves a tool from one location + to another. + + + + + + + + + + leaf {{block(Component)}} that physically moves a tool from one location + to another. + + + + + + + leaf {{block(Component)}} composed of a rotary storage unit for + material. + + + + + + + + + + leaf {{block(Component)}} composed of a rotary storage unit for + material. + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + been removed from {{term(spindle)}} or {{block(Turret)}} and awaiting + for return to a {{block(ToolMagazine)}}. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that has + been removed from {{term(spindle)}} or {{block(Turret)}} and awaiting + for return to a {{block(ToolMagazine)}}. + + + + + + + leaf {{block(Component)}} composed of interconnected series of objects + that band together and are used to transmit motion for a piece of + equipment or to convey materials and objects. + + + + + + + + + + leaf {{block(Component)}} composed of interconnected series of objects + that band together and are used to transmit motion for a piece of + equipment or to convey materials and objects. + + + + + + + leaf {{block(Component)}} composed of an electronic component or circuit + that amplifies power, electric current, or voltage. + + + + + + + + + + leaf {{block(Component)}} composed of an electronic component or circuit + that amplifies power, electric current, or voltage. + + + + + + + leaf {{block(Component)}} generally composed of an open container. + + + + + + + + + + leaf {{block(Component)}} generally composed of an open container. + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is no + longer usable for removal from a {{block(ToolMagazine)}} or + {{block(Turret)}}. + + + + + + + + + + leaf {{block(Component)}} that is a {{block(Pot)}} for a tool that is no + longer usable for removal from a {{block(ToolMagazine)}} or + {{block(Turret)}}. + + + + + + + leaf {{block(Component)}} composed of a viscous liquid. + + + + + + + + + + leaf {{block(Component)}} composed of a viscous liquid. + + + + + + + leaf {{block(Component)}} composed of a surface for holding an object or + material. + + + + + + + + + + leaf {{block(Component)}} composed of a surface for holding an object or + material. + + + + + + + leaf {{block(Component)}} that breaks material into smaller pieces. + + + + + + + + + + leaf {{block(Component)}} that breaks material into smaller pieces. + + + + + + + leaf {{block(Component)}} that halts or controls the flow of a liquid, + gas, or other material through a passage, pipe, inlet, or outlet. + + + + + + + + + + leaf {{block(Component)}} that halts or controls the flow of a liquid, + gas, or other material through a passage, pipe, inlet, or outlet. + + + + + + + leaf {{block(Component)}} composed of a tool storage location associated + with a {{block(ToolMagazine)}} or {{block(AutomaticToolChanger)}}. + + + + + + + + + + leaf {{block(Component)}} composed of a tool storage location associated + with a {{block(ToolMagazine)}} or {{block(AutomaticToolChanger)}}. + + + + + + + leaf {{block(Component)}} that transforms electric energy from a source + to a secondary circuit. + + + + + + + + + + leaf {{block(Component)}} that transforms electric energy from a source + to a secondary circuit. + + + + + + + leaf {{block(Component)}} that emits a type of radiation. + + + + + + + + + + leaf {{block(Component)}} that emits a type of radiation. + + + + + + + leaf {{block(Component)}} generally composed of an enclosed container. + + + + + + + + + + leaf {{block(Component)}} generally composed of an enclosed container. + + + + + + + leaf {{block(Component)}} that measures position. + + + + + + + + + + leaf {{block(Component)}} that measures position. + + + + + + + leaf {{block(Component)}} composed of one or more cells in which + chemical energy is converted into electricity and used as a source of + power. + + + + + + + + + + leaf {{block(Component)}} composed of one or more cells in which + chemical energy is converted into electricity and used as a source of + power. + + + + + + + leaf {{block(Component)}} that interrupts an electric circuit. + + + + + + + + + + leaf {{block(Component)}} that interrupts an electric circuit. + + + + + + + leaf {{block(Component)}} that converts electrical, pneumatic, or + hydraulic energy into mechanical energy. + + + + + + + + + + leaf {{block(Component)}} that converts electrical, pneumatic, or + hydraulic energy into mechanical energy. + + + + + + + leaf {{block(Component)}} that dispenses liquid or powered materials. + + + + + + + + + + leaf {{block(Component)}} that dispenses liquid or powered materials. + + + + + + + leaf {{block(Component)}} composed of an electromechanical actuator that + produces deflection of a beam of light or energy in response to electric + current through its coil in a magnetic field. + + + + + + + + + + leaf {{block(Component)}} composed of an electromechanical actuator that + produces deflection of a beam of light or energy in response to electric + current through its coil in a magnetic field. + + + + + + + leaf {{block(Component)}} that raises, drives, exhausts, or compresses + fluids or gases by means of a piston, plunger, or set of rotating vanes. + + + + + + + + + + leaf {{block(Component)}} that raises, drives, exhausts, or compresses + fluids or gases by means of a piston, plunger, or set of rotating vanes. + + + + + + + leaf {{block(Component)}} that strengthens, support, or fastens objects + in place. + + + + + + + + + + leaf {{block(Component)}} that strengthens, support, or fastens objects + in place. + + + + + + + leaf {{block(Component)}} that measures linear motion or position. + **DEPRECATION WARNING** : May be deprecated in the future. Recommend + using {{block(Encoder)}}. + + + + + + + + + + leaf {{block(Component)}} that measures linear motion or position. + **DEPRECATION WARNING** : May be deprecated in the future. Recommend + using {{block(Encoder)}}. + + + + + + + leaf {{block(Component)}} composed of an object or material on which a + form of work is performed. + + + + + + + + + + leaf {{block(Component)}} composed of an object or material on which a + form of work is performed. + + + + + + + Description + + + + + + + + + + Description + + + + + + + {{block(Component)}} that provides information related to an individual + {{term(feature)}}. + + + + + + + + + + {{block(Component)}} that provides information related to an individual + {{term(feature)}}. + + + + + + + system that circulates air or regulates airflow without altering + temperature or humidity. + + + + + + + + + + system that circulates air or regulates airflow without altering + temperature or humidity. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Structure)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Structure)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Interface)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Interface)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Auxiliary)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Auxiliary)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(System)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(System)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Adapter)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Adapter)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Resource)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Resource)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Component + Types::Axis)}} types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Component + Types::Axis)}} types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Process)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Process)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Part)}} + types. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Part)}} + types. + + + + + + + {{block(Resources)}} that {{termplural(organize)}} {{block(Material)}} + types. + + + + + + + + + + {{block(Resources)}} that {{termplural(organize)}} {{block(Material)}} + types. + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Controller)}} + entities. + + + + + + + + + + {{block(Component)}} that {{termplural(organize)}} {{block(Controller)}} + entities. + + + + + + + Compositions Model + + + + + + + Description + + + + + + + + + Extended tyoe for The vocab for the type of composition + + + + + + + + + + The vocab for the type of composition + + + + + + + {{block(Composition)}} composed of a mechanism that moves or + controls a mechanical part of a piece of equipment. It takes energy + usually provided by air, electric current, or liquid and converts + the energy into some kind of motion. + + + + + + + {{block(Composition)}} composed of an electronic component or + circuit that amplifies power, electric current, or voltage. + + + + + + + {{block(Composition)}} composed of a mechanical structure that + transforms rotary motion into linear motion. + + + + + + + {{block(Composition)}} composed of an endless flexible band that + transmits motion for a piece of equipment or conveys materials and + objects. + + + + + + + {{block(Composition)}} composed of a mechanism that slows down or + stops a moving object by the absorption or transfer of the energy of + momentum, usually by means of friction, electrical force, or + magnetic force. + + + + + + + {{block(Composition)}} composed of an interconnected series of + objects that band together and transmit motion for a piece of + equipment or to convey materials and objects. + + + + + + + {{block(Composition)}} composed of a mechanism that breaks material + into smaller pieces. + + + + + + + {{block(Composition)}} composed of a mechanism that holds a part, + stock material, or any other item in place. + + + + + + + {{block(Composition)}} composed of an inclined channel that conveys + material. + + + + + + + {{block(Composition)}} composed of a mechanism that interrupts an + electric circuit. + + + + + + + {{block(Composition)}} composed of a mechanism that strengthens, + supports, or fastens objects in place. + + + + + + + {{block(Composition)}} composed of a pump or other mechanism that + reduces volume and increases pressure of gases in order to condense + the gases to drive pneumatically powered pieces of equipment. + + + + + + + {{block(Composition)}} composed of a mechanical mechanism or closure + that covers a physical access portal into a piece of equipment + allowing or restricting access to other parts of the equipment. + + + + + + + {{block(Composition)}} composed of a mechanism that allows material + to flow for the purpose of drainage from, for example, a vessel or + tank. + + + + + + + {{block(Composition)}} composed of a mechanism that measures rotary + position. + + + + + + + {{block(Composition)}} composed of a mechanism that emits a type of + radiation. + + + + + + + {{block(Composition)}} composed of a mechanism that dispenses liquid + or powered materials. + + + + + + + {{block(Composition)}} composed of a mechanism that produces a + current of air. + + + + + + + {{block(Composition)}} composed of a substance or structure that + allows liquids or gases to pass through to remove suspended + impurities or to recover solids. + + + + + + + {{block(Composition)}} composed of an electromechanical actuator + that produces deflection of a beam of light or energy in response to + electric current through its coil in a magnetic field. + + + + + + + {{block(Composition)}} composed of a mechanism that holds a part, + stock material, or any other item in place. + + + + + + + {{block(Composition)}} composed of a chamber or bin that stores + materials temporarily, typically being filled through the top and + dispensed through the bottom. + + + + + + + {{block(Composition)}} composed of a mechanism that measures linear + motion or position. + + + + + + + {{block(Composition)}} composed of a mechanism that converts + electrical, pneumatic, or hydraulic energy into mechanical energy. + + + + + + + {{block(Composition)}} composed of a viscous liquid. + + + + + + + {{block(Composition)}} composed of a unit that provides power to + electric mechanisms. + + + + + + + {{block(Composition)}} composed of a mechanism or wheel that turns + in a frame or block and serves to change the direction of or to + transmit force. + + + + + + + {{block(Composition)}} composed of an apparatus that raises, drives, + exhausts, or compresses fluids or gases by means of a piston, + plunger, or set of rotating vanes. + + + + + + + {{block(Composition)}} composed of a rotary storage unit for + material. + + + + + + + {{block(Composition)}} composed of a mechanism that provides a + signal or measured value. + + + + + + + {{block(Composition)}} composed of a mechanism that flattens or + spreads materials. + + + + + + + {{block(Composition)}} composed of one or more cells that converts + chemical energy to electricity and serves as a source of power. + + + + + + + {{block(Composition)}} composed of a mechanism that turns on or off + an electric current or makes or breaks a circuit. + + + + + + + {{block(Composition)}} composed of a surface that holds an object or + material. + + + + + + + {{block(Composition)}} composed of a receptacle or container that + holds material. + + + + + + + {{block(Composition)}} composed of a mechanism that provides or + applies a stretch or strain to another mechanism. + + + + + + + {{block(Composition)}} composed of a mechanism that transforms + electric energy from a source to a secondary circuit. + + + + + + + {{block(Composition)}} composed of a mechanism that halts or + controls the flow of a liquid, gas, or other material through a + passage, pipe, inlet, or outlet. + + + + + + + {{block(Composition)}} composed of a container for liquid or + powdered materials. + + + + + + + {{block(Composition)}} composed of a fluid. + + + + + + + {{block(Composition)}} composed of a string like piece or filament + of relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + {{block(Composition)}} composed of an object or material on which a + form of work is performed. + + + + + + + {{block(Composition)}} composed of a heat exchange system that uses + a fluid to transfer heat to the atmosphere. + + + + + + + {{block(Composition)}} composed of a tool storage location + associated with a {{block(ToolMagazine)}} or + {{block(AutomaticToolChanger)}}. + + + + + + + {{block(Composition)}} composed of a storage or mounting location + for a tool associated with a {{block(Turret)}}, + {{block(GangToolBar)}}, or {{block(ToolRack)}}. + + + + + + + {{block(Composition)}} composed of a mechanism that physically moves + a tool from one location to another. + + + + + + + {{block(Pot)}} for a tool awaiting transfer from a + {{block(ToolMagazine)}} to {{term(spindle)}} or {{block(Turret)}}. + + + + + + + {{block(Pot)}} for a tool removed from {{term(spindle)}} or + {{block(Turret)}} and awaiting for return to a + {{block(ToolMagazine)}}. + + + + + + + {{block(Pot)}} for a tool awaiting transfer to a + {{block(ToolMagazine)}} or {{block(Turret)}} from outside of the + piece of equipment. + + + + + + + {{block(Pot)}} for a tool to be removed from a + {{block(ToolMagazine)}} or {{block(Turret)}} to a location outside + of the piece of equipment. + + + + + + + {{block(Pot)}} for a tool that is no longer usable for removal from + a {{block(ToolMagazine)}} or {{block(Turret)}}. + + + + + + + + + The vocab for the type of composition + + + + + + + + Description + + + + + + + See {{sect(Description)}}. + + + + + + + technical information about an entity describing its physical + layout, functional characteristics, and relationships with other + entities. + + + + + + + + unique identifier for the power source. + + + + + + + The composition's universally unique id. + + + + + + + identifier of the maintenance activity. + + + + + + + The type of composition + + + + + + + + A reference to an identifier + + + + + + + + References Model + + + + + + + + + + Description + + + + + + A reference to an id in the MTConnectDevices model + + + + + + + identifier of the maintenance activity. + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Description + + + + + + + + + + Description + + + + + + + Abstract configuration + + + + + + + Abstract configuration + + + + + + + The configuration data associated with this component. + + + + + + + + + + The time the calibration was preformed + + + + + + + + The time the next calibration should be preformed + + + + + + + + The initials of the person doing the calibration + + + + + + + + The firmware version of this sensor + + + + + + + + The channel number + + + + + + + + See {{block(SensorConfiguration)}}. + + + + + + + + + Version number for the sensor unit as specified by the + manufacturer. + + + + + + + Date upon which the {{term(sensor unit)}} was last calibrated to + the {{term(sensor element)}}. + + + + + + + Date upon which the {{term(sensor element)}} is next scheduled + to be calibrated with the {{term(sensor unit)}}. + + + + + + + The initials of the person verifying the validity of the + calibration data. + + + + + + + {{block(Channels)}} groups one or more {{block(Channel)}} + entities. See {{block(Channel)}}. + + + + + + + + + + + See {{block(SensorConfiguration)}}. + + + + + + + {{block(Channels)}} groups one or more {{block(Channel)}} entities. See + {{block(Channel)}}. + + + + + + + Description + + + + + + + + + Description + + + + + + + See {{sect(Description)}}. + + + + + + + Date upon which the {{term(sensor unit)}} was last calibrated to the + {{term(sensor element)}}. + + + + + + + Date upon which the {{term(sensor element)}} is next scheduled to be + calibrated with the {{term(sensor unit)}}. + + + + + + + The initials of the person verifying the validity of the calibration + data. + + + + + + + + The channel id + + + + + + + identifier of the maintenance activity. + + + + + + + + The peak value + + + + + + + + {{block(Specifications)}} groups one or more {{block(Specification)}} + entities. See {{package(Specifications)}}. + + + + + + + + + + + + + + {{block(Specifications)}} groups one or more {{block(Specification)}} + entities. See {{package(Specifications)}}. + + + + + + + Extended tyoe for A reference to the creator of the Specification + + + + + + + + + + A reference to the creator of the Specification + + + + + + + The manufacturer of a piece of equipment or component. + + + + + + + The owner or implementer of a piece of equipment or component. + + + + + + + + + A reference to the creator of the Specification + + + + + + + + A specification + + + + + + The identity of the Specificaiton + + + + + + + The type of measurement + + + + + + + A reference to the creator of the Specification + + + + + + + The type of measurement + + + + + + + identifier of the maintenance activity. + + + + + + + The optional data item identifier + + + + + + + The optional composition identifier + + + + + + + The optional coordinate system identifier + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + A specification + + + + + + + design characteristics for a piece of equipment. + + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may + be required. + + + + + + + lower boundary indicating increased concern and supervision may + be required. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + + + design characteristics for a piece of equipment. + + + + + + + The limit of a constraint + + + + + + + + + + The limit of a constraint + + + + + + + numeric upper constraint. + + + + + + + + + + numeric upper constraint. + + + + + + + numeric lower constraint. + + + + + + + + + + numeric lower constraint. + + + + + + + numeric target or expected value. + + + + + + + + + + numeric target or expected value. + + + + + + + upper conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + + + + upper conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + lower conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + + + + lower conformance boundary for a variable. > Note: immediate concern + or action may be required. + + + + + + + {{block(Specification)}} that provides information used to assess the + conformance of a variable to process requirements. + + + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + + + + + {{block(Specification)}} that provides information used to assess the + conformance of a variable to process requirements. + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + numeric target or expected value. + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + upper boundary indicating increased concern and supervision may be + required. + + + + + + + lower boundary indicating increased concern and supervision may be + required. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + upper conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + numeric target or expected value. + + + + + + + lower conformance boundary for a variable. > Note: immediate + concern or action may be required. + + + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + The list of possible association types + + + + + + + The related entity is a parent + + + + + + + The related entity is a child + + + + + + + The related entity is a peer + + + + + + + + + device relationships + + + + + + + a system + + + + + + + an auxiliary + + + + + + + + + The criticality + + + + + + + critical + + + + + + + Not critical + + + + + + + + + A relationship between this component and something else + + + + + + The relationship identifier + + + + + + + identifier of the maintenance activity. + + + + + + + The assciation type + + + + + + + Criticality + + + + + + + + A relationship between this component and something else + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two components within a piece of equipment that function + independently but together perform a capability or service within a + piece of equipment. + + + + + + + + A reference to the device uuid + + + + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two components within a piece of equipment that function + independently but together perform a capability or service within a + piece of equipment. + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two pieces of equipment that function independently but together + perform a manufacturing operation. + + + + + + + + A reference to the device uuid + + + + + + + The type of relatiship + + + + + + + {{term(URL)}} giving the location of the image file. + + + + + + + Description + + + + + + + + + + {{block(ConfigurationRelationship)}} that describes the association + between two pieces of equipment that function independently but together + perform a manufacturing operation. + + + + + + + The type of coordinate system + + + + + + + The world + + + + + + + The base of the manipulator chain + + + + + + + The object + + + + + + + The current task + + + + + + + The last joint in the chain + + + + + + + The tool's coord + + + + + + + The platform + + + + + + + For machine tools, the coordinate system in the work area + + + + + + + For machine tools, the coordinate system in the work area + + + + + + + + + {{block(CoordinateSystems)}} groups one or more + {{block(CoordinateSystem)}} entities. See + {{package(CoordinateSystems)}}. + + + + + + + + + Description + + + + + + + + + + + {{block(CoordinateSystems)}} groups one or more + {{block(CoordinateSystem)}} entities. See + {{package(CoordinateSystems)}}. + + + + + + + Description + + + + + + + See {{sect(Origin)}}. + + + + + + + See {{sect(Transformation)}}. + + + + + + + + The coordinate system identifier + + + + + + + identifier of the maintenance activity. + + + + + + + The optional name of the coordinate system + + + + + + + The parent of the coordinate system + + + + + + + The coordinate system type + + + + + + + uuid + + + + + + + + See {{sect(Origin)}}. + + + + + + + + + + See {{sect(Transformation)}}. + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + The types of motion + + + + + + + Rotates around an axis with a fixed range of motion + + + + + + + Revolves around an axis with a continuous range of motion + + + + + + + Sliding linear motion along an axis with a fixed range of motion + + + + + + + The axis does not move. + + + + + + + + + The actuation of this component + + + + + + + The movement is initiated by the component. + + + + + + + The motion is computed and is used for expressing an imaginary + movement. + + + + + + + There is no actuation of this Axis. + + + + + + + + + The unit vector along which the motion occurs + + + + + + + + + + The description of the motion + + + + + + + Any elements + + + + + + + + + See {{sect(Motion)}}. + + + + + + + + + See {{sect(Description)}}. + + + + + + + + See {{sect(Origin)}}. + + + + + + + See {{sect(Transformation)}}. + + + + + + + + See {{sect(Axis)}}. + + + + + + + + The coordinate system identifier + + + + + + + The parent of the coordinate system + + + + + + + The identifier of the coordinate system that this motion is + relative to + + + + + + + The motion type + + + + + + + The actuation method + + + + + + + + + + See {{sect(Motion)}}. + + + + + + + A reference to another model + + + + + + + + A reference to an item in a model + + + + + + + + See {{sect(SolidModel)}}. + + + + + + + + + See {{sect(Transformation)}}. + + + + + + + See {{sect(Scale)}}. + + + + + + + + the unique identifier for this entity within the MTConnectDevices + document + + + + + + + The associated model file if an item reference is used + + + + + + + {{term(URL)}} giving the location of the image file. + + + + + + + Description + + + + + + + The reference to the item within the model within the related + geometry. A modelIdRef MUST be given. + + + + + + + The format of the referenced document + + + + + + + The identifier of the coordinate system that this motion is + relative to + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The units as expressed by the machine + + + + + + + + + + See {{sect(SolidModel)}}. + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + The unit vector to scale the model + + + + + + + + + + Extended tyoe for Solid model media types + + + + + + + + + + Solid model media types + + + + + + + ISO 10303 STEP AP203 or AP242 format + + + + + + + Stereolithography file format + + + + + + + Geometry Description Markup Language + + + + + + + Wavefront OBJ file format + + + + + + + ISO 17506 + + + + + + + Initial Graphics Exchange Specification + + + + + + + Autodesk file format + + + + + + + Dassault file format + + + + + + + Parasolid XT Siemens data interchange format + + + + + + + + + Solid model media types + + + + + + + + url of an image file + + + + + + + + mime type + + + + + + + + This section provides semantic information for the {{block(ImageFile)}} + entity. + + + + + + + + + reference to a file containing an image of the + {{block(Component)}}. + + + + + + + + + + + This section provides semantic information for the {{block(ImageFile)}} + entity. + + + + + + + reference to a file containing an image of the {{block(Component)}}. + + + + + + + + identifier + + + + + + + identifier of the maintenance activity. + + + + + + + URL of image file + + + + + + + mime type of image file + + + + + + + + + + The item's reference to the component + + + + + + + + The name of the power source + + + + + + + + The order of precedence for a given power source + + + + + + + + The type of power source + + + + + + + main or principle + + + + + + + alternate or not primary + + + + + + + held near at hand and ready for use and is uninterruptible + + + + + + + + + This section provides semantic information for the + {{block(PowerSource)}} entity. ![PowerSources](figures/PowerSources.png + "PowerSources"){: width="0.8"} + + + + + + + + + potential energy sources for the {{block(Component)}}. + + + + + + + + + + + This section provides semantic information for the + {{block(PowerSource)}} entity. ![PowerSources](figures/PowerSources.png + "PowerSources"){: width="0.8"} + + + + + + + potential energy sources for the {{block(Component)}}. + + + + + + + optional precedence for a given power source + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST NOT** + be used in conjunction with any other {{block(Constraint)}} + elements. + + + + + + + + type of power source + + + + + + + identifier + + + + + + + reference to component + + + + + + + + The interval between adjacent sampleing of data + + + + + + + + The frequency a measurement is sampled + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + The constrained value for this data item + + + + + + + + An idref to the component id + + + + + + + + An idref to the data item id + + + + + + + + The item's reference to the data item or specificatiton + + + + + + + + The name of a related component + + + + + + + + The id reference for the coordinate system associated with this data + item + + + + + + + + An discrete event + + + + + + + + The description of a data item, can be free form text or elements + + + + + + + Any elements + + + + + + + + + The minimum limit on the change in a value + + + + + + + + The measurement sampling type + + + + + + + An event represents a change in state occurs at a point in time. + Note: An event does not occur at predefined frequencies. + + + + + + + A sample is a data point for continuous data items, that is, the + value of a data item at a point in time. + + + + + + + The condition of the device + + + + + + + + + The multiplier for the native value. Conversion divides by this value + + + + + + + + Description + + + + + + + series of sampled data. The data is reported for a specified number + of samples and each sample is reported with a fixed period. + + + + + + + measured value of the sample data. If no + {{property(DataItem::representation)}} is specified for a data item, + the {{property(DataItem::representation)}} **MUST** be determined to + be `VALUE`. + + + + + + + reported value(s) are represented as a set of {{termplural(key-value + pair)}}. Each reported value in the {{term(data set)}} **MUST** have + a unique key. + + + + + + + **DEPRECATED** as {{property(DataItem::representation)}} type in + *MTConnect Version 1.5*. Replaced by the + {{property(DataItem::discrete)}}. + + + + + + + two dimensional set of {{termplural(key-value pair)}} where the + {{block(Entry)}} represents a row, and the value is a set of + {{term(key-value pair)}} {{block(Cell)}} elements. A {{term(table)}} + follows the same behavior as the {{term(data set)}} for change + tracking, clearing, and history. When an {{block(Entry)}} changes, + all {{block(Cell)}} elements update as a single unit following the + behavior of a {{term(data set)}}. > Note: It is best to use + {{block(Variable)}} if the {{block(Cell)}} entities represent + multiple semantic types. Each {{block(Entry)}} in the + {{term(table)}} **MUST** have a unique key. Each {{block(Cell)}} of + each {{block(Entry)}} in the {{term(table)}} **MUST** have a unique + key. See {{block(Representation)}} in {{package(Observation + Information Model)}}, for a description of {{block(Entry)}} and + {{block(Cell)}} elements. + + + + + + + + + The type of filter + + + + + + + new value **MUST NOT** be reported for a data item unless the + measured value has changed from the last reported value by at least + the delta given as the value of this element. The value of + {{block(Filter)}} **MUST** be an absolute value using the same units + as the reported data. + + + + + + + data reported for a data item is provided on a periodic basis. The + `PERIOD` for reporting data is defined in the value of the + {{block(Filter)}}. The value of {{block(Filter)}} **MUST** be an + absolute value reported in seconds representing the time between + reported samples of the value of the data item. + + + + + + + + + + + + + + information reported about a piece of equipment. + + + + + + + + + information reported about a piece of equipment. + + + + + + + identifies the {{block(Component)}}, {{block(DataItem)}}, or + {{block(Composition)}} from which a measured value originates. + + + + + + + {{termplural(organize)}} a set of expected values that can be + reported for a {{block(DataItem)}}. + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + starting value for a {{block(DataItem)}} as well as the value to be + set for the {{block(DataItem)}} after a reset event. + + + + + + + type of event that may cause a reset to occur. + + + + + + + defines the meaning of {{block(Entry)}} and {{block(Cell)}} entities + when the associated {{property(DataItem::representation)}} is either + `DATA_SET` or `TABLE`. + + + + + + + {{block(Relationships)}} groups one or more + {{block(ConfigurationRelationship)}} types. See + {{package(Relationships)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + unique identifier for the power source. + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + The statistical operation on this data + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + The units as expressed by the machine + + + + + + + The units as expressed by the machine + + + + + + + The category of the data item + + + + + + + Description + + + + + + + The coordinate system reference to a particular coordinate system + + + + + + + The optional composition identifier + + + + + + + Used as the default sample rate for waveforms + + + + + + + Description + + + + + + + The number of significant digits for this data item + + + + + + + Description + + + + + + + + A set of limits for a data item + + + + + + + + + single data value that is expected to be reported for a + {{block(DataItem)}}. {{property(Constraints::Value)}} **MUST + NOT** be used in conjunction with any other + {{block(Constraint)}} elements. + + + + + + + + + numeric lower constraint. + + + + + + + numeric upper constraint. + + + + + + + numeric target or expected value. + + + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + {{block(Filters)}} groups one or more {{block(Filter)}} entities + associated with the {{block(DataItem)}}. + + + + + + + **DEPRECATED** in *MTConnect Version 1.4*. Moved to the + {{block(Filters)}}. See {{package(Properties of DataItem)}}. + + + + + + + + + A starting point for a data item + + + + + + + + + + The value element + + + + + + + + + + The filter for the data item + + + + + + + + The type of filter, ABSOLUTE or PERCENT + + + + + + + + + + A native data source + + + + + + + + The optional data item within the source component that provides + the underlying data + + + + + + + The component that is collecting the data associated with this + data item + + + + + + + The optional composition identifier for the source of this data + item + + + + + + + + + + The DataItem Definition + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + {{block(EntryDefinitions)}} groups one or more + {{block(EntryDefinition)}} entities. See {{sect(EntryDefinition)}}. + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + + + + unique key + + + + + + + The type of measurement + + + + + + + The type of measurement + + + + + + + The sub type for the measurement + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device + Information Model)}}. + + + + + + + + semantic definition of an {{block(Entry)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + {{block(CellDefinitions)}} groups one or more + {{block(CellDefinition)}} entities. See {{sect(CellDefinition)}}. + + + + + + + + + + {{block(CellDefinitions)}} groups one or more {{block(CellDefinition)}} + entities. See {{sect(CellDefinition)}}. + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + + + semantic definition of a {{block(Cell)}}. + + + + + + + See {{sect(Description)}}. + + + + + + + + + + Organizes DataItemRelationship and SpecificationRelationship + + + + + + + + + + Description + + + + + + identifier of the maintenance activity. + + + + + + + A reference to the related DataItem id. + + + + + + + + Description + + + + + + + How the data items are related + + + + + + + A reference to a DataItem that associates the values with an + external entity + + + + + + + The referenced DataItem provides the id of the effective Coordinate + System + + + + + + + The referenced DataItem provides process limits. + + + + + + + The referenced DataItem provides the observed values. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(DataItem)}} described by + {{property(DataItemRelationship::type)}}. + + + + + + + How the data items are related + + + + + + + The referenced DataItem provides process limits. + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + + + + + type of the power source. + + + + + + + + + + {{block(AbstractDataItemRelationship)}} that provides a semantic + reference to another {{block(Specification)}} described by + {{property(SpecificationRelationship::type)}} and + {{property(SpecificationRelationship::idRef)}}. + + + + \ No newline at end of file diff --git a/schemas/MTConnectError_2.4.xsd b/schemas/MTConnectError_2.4.xsd new file mode 100644 index 00000000..1fc2e648 --- /dev/null +++ b/schemas/MTConnectError_2.4.xsd @@ -0,0 +1,4667 @@ + + + + + + + root entity of an {{term(MTConnectErrors Response Document)}} that + contains the {{term(Error Information Model)}}. + ![MTConnectError](figures/MTConnectErrors.png + "MTConnectError"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectError)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + The size of the agent's buffer. + + + + + + + + + + root entity of an {{term(MTConnectErrors Response Document)}} that + contains the {{term(Error Information Model)}}. + ![MTConnectError](figures/MTConnectErrors.png + "MTConnectError"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectError)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + + error encountered by an {{term(agent)}} when responding to a + {{term(request)}}. + + + + + + + {{block(Errors)}} groups one or more {{block(Error)}} entities. + See {{sect(Error)}}. > Note: When compatibility with Version + 1.0.1 and earlier of the MTConnect Standard is required for an + implementation, the {{term(MTConnectErrors Response Document)}} + contains only a single {{block(Error)}} entity and the + {{block(Errors)}} entity **MUST NOT** appear in the document. + + + + + + + + + + {{block(Errors)}} groups one or more {{block(Error)}} entities. See + {{sect(Error)}}. > Note: When compatibility with Version 1.0.1 and + earlier of the MTConnect Standard is required for an implementation, the + {{term(MTConnectErrors Response Document)}} contains only a single + {{block(Error)}} entity and the {{block(Errors)}} entity **MUST NOT** + appear in the document. + + + + + + + error encountered by an {{term(agent)}} when responding to a + {{term(request)}}. + + + + + + + + + The text description of the error + + + + + + + + The error code + + + + + + + The request did not have sufficient permissions to perform the + request. + + + + + + + The device specified in the URI could not be found. + + + + + + + The sequence number was beyond the end of the buffer. + + + + + + + The count given is too large. + + + + + + + The URI provided was incorrect. + + + + + + + The request was not one of the three specified requests. + + + + + + + Contact the software provider, the agent did not behave correctly. + + + + + + + The xpath could not be parsed. Invalid syntax. + + + + + + + The request is not supported by this implementation + + + + + + + The asset ID cannot be found + + + + + + + + + error encountered by an {{term(agent)}} when responding to a + {{term(request)}}. + + + + + + + + The error code + + + + + + + \ No newline at end of file diff --git a/schemas/MTConnectError_2.4_1.0.xsd b/schemas/MTConnectError_2.4_1.0.xsd new file mode 100644 index 00000000..3440a7ef --- /dev/null +++ b/schemas/MTConnectError_2.4_1.0.xsd @@ -0,0 +1,4667 @@ + + + + + + + root entity of an {{term(MTConnectErrors Response Document)}} that + contains the {{term(Error Information Model)}}. + ![MTConnectError](figures/MTConnectErrors.png + "MTConnectError"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectError)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + The size of the agent's buffer. + + + + + + + + + + root entity of an {{term(MTConnectErrors Response Document)}} that + contains the {{term(Error Information Model)}}. + ![MTConnectError](figures/MTConnectErrors.png + "MTConnectError"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectError)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + + error encountered by an {{term(agent)}} when responding to a + {{term(request)}}. + + + + + + + {{block(Errors)}} groups one or more {{block(Error)}} entities. + See {{sect(Error)}}. > Note: When compatibility with Version + 1.0.1 and earlier of the MTConnect Standard is required for an + implementation, the {{term(MTConnectErrors Response Document)}} + contains only a single {{block(Error)}} entity and the + {{block(Errors)}} entity **MUST NOT** appear in the document. + + + + + + + + + + {{block(Errors)}} groups one or more {{block(Error)}} entities. See + {{sect(Error)}}. > Note: When compatibility with Version 1.0.1 and + earlier of the MTConnect Standard is required for an implementation, the + {{term(MTConnectErrors Response Document)}} contains only a single + {{block(Error)}} entity and the {{block(Errors)}} entity **MUST NOT** + appear in the document. + + + + + + + error encountered by an {{term(agent)}} when responding to a + {{term(request)}}. + + + + + + + + + The text description of the error + + + + + + + + The error code + + + + + + + The request did not have sufficient permissions to perform the + request. + + + + + + + The device specified in the URI could not be found. + + + + + + + The sequence number was beyond the end of the buffer. + + + + + + + The count given is too large. + + + + + + + The URI provided was incorrect. + + + + + + + The request was not one of the three specified requests. + + + + + + + Contact the software provider, the agent did not behave correctly. + + + + + + + The xpath could not be parsed. Invalid syntax. + + + + + + + The request is not supported by this implementation + + + + + + + The asset ID cannot be found + + + + + + + + + error encountered by an {{term(agent)}} when responding to a + {{term(request)}}. + + + + + + + + The error code + + + + + + + \ No newline at end of file diff --git a/schemas/MTConnectStreams_2.4.xsd b/schemas/MTConnectStreams_2.4.xsd new file mode 100644 index 00000000..2a9f6f5a --- /dev/null +++ b/schemas/MTConnectStreams_2.4.xsd @@ -0,0 +1,46137 @@ + + + + + + + root entity of an {{term(MTConnectStreams Response Document)}} that + contains the {{term(Observation Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectStreams](figures/MTConnectStreams.png + "MTConnectStreams"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectStreams)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + The station id for this device + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + + + The size of the agent's buffer. + + + + + + + The next sequence number for subsequent requests + + + + + + + The last sequence number available from the agent + + + + + + + The first sequence number available from the agent + + + + + + + + + + root entity of an {{term(MTConnectStreams Response Document)}} that + contains the {{term(Observation Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectStreams](figures/MTConnectStreams.png + "MTConnectStreams"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectStreams)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + {{block(Streams)}} groups one or more {{block(DeviceStream)}} + entities. See {{package(Observation Information Model)}} for more + detail. + + + + + + + + + An events data + + + + + + + + The item's unique ID that references the data item id from probe + + + + + + + + An Condition code as defined by the component + + + + + + + + {{block(Streams)}} groups one or more {{block(DeviceStream)}} entities. + See {{package(Observation Information Model)}} for more detail. + + + + + + + Description + + + + + + + + + Description + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} + for the {{block(ComponentStream)}} model. > Note 1 to entry: In + the {{term(XML)}} representation, {{block(ComponentStream)}} + entities **MUST NOT** appear in the {{term(MTConnectDevices Response + Document)}}. > Note 2 to entry: In the {{term(XML)}} + representation, {{block(ComponentStream)}} entities **MUST** appear + only in the {{term(MTConnectStreams Response Document)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + The unque identifier for this device + + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} for + the {{block(ComponentStream)}} model. > Note 1 to entry: In the + {{term(XML)}} representation, {{block(ComponentStream)}} entities **MUST + NOT** appear in the {{term(MTConnectDevices Response Document)}}. > + Note 2 to entry: In the {{term(XML)}} representation, + {{block(ComponentStream)}} entities **MUST** appear only in the + {{term(MTConnectStreams Response Document)}}. + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. + See {{sect(Sample)}}. + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + Description + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + identifier of the maintenance activity. + + + + + + + The device manufacturer component name + + + + + + + Description + + + + + + + The unque identifier for this component + + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. See + {{sect(Sample)}}. + + + + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + + + + A collection of conditions + + + + + + + + + + The observation value for indeterminent data + + + + + + + Data is unavailable + + + + + + + + + + The events sequence number + + + + + + + The event subtype corresponding to the measurement subtype + + + + + + + The time the event occurred or recorded + + + + + + + identifier of the maintenance activity. + + + + + + + The unique identifier of the item being produced + + + + + + + The identifier of the sub-element this result is in reference to + + + + + + + + The target rate a value can be sampled + + + + + + + + The number of items in the list + + + + + + + + Common floating point sample value + + + + + + + + Common floating point sample value + + + + + + + + Description + + + + + + + The rate the waveform was sampled at, default back to the value given + in the data item + + + + + + + An optional indicator that the event or sample was reset + + + + + + + The statistical operation on this data + + + + + + + The number of seconds since the reset of the statistic + + + + + + + + Description + + + + + + + A sample with a single floating point value + + + + + + + + + + + + + + A sample with a single floating point value + + + + + + + A sample with a three tuple floating point value + + + + + + + + + + + + + + A sample with a three tuple floating point value + + + + + + + The abstract waveform + + + + + + + + The number of samples + + + + + + + + + + The abstract waveform + + + + + + + Description + + + + + + + + + + + + + + Description + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Example + + + + + + + + + + Example + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Description + + + + + + + + + + Description + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + Integer event value + + + + + + + + Integer event value + + + + + + + + String event value + + + + + + + + DateTime String event value + + + + + + + + A list of axis names + + + + + + + + + + + + A list of axis for an event + + + + + + + + Common floating point event value + + + + + + + + Description + + + + + + + An optional indicator that the event or sample was reset + + + + + + + + Description + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted datetime event + + + + + + + + + + + + + + An unfaceted datetime event + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with a three tuple floating point value + + + + + + + + + + + + + + An event with a three tuple floating point value + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Controlled vocabulary for ActuatorState + + + + + + + {{block(Actuator)}} is operating. + + + + + + + {{block(Actuator)}} is not operating. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Controlled vocabulary for Availability + + + + + + + data source is active and capable of providing data. + + + + + + + data source is either inactive or not capable of providing data. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + Controlled vocabulary for AxisCoupling + + + + + + + axes are physically connected to each other and operate as a single + unit. + + + + + + + axes are not physically connected to each other but are operating + together in lockstep. + + + + + + + axis is the master of the {{block(CoupledAxes)}}. + + + + + + + axis is a slave to the {{block(CoupledAxes)}}. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for AxisInterlock + + + + + + + axis lockout function is activated, power has been removed from the + axis, and the axis is allowed to move freely. + + + + + + + axis lockout function has not been activated, the axis may be + powered, and the axis is capable of being controlled by another + component. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Controlled vocabulary for AxisState + + + + + + + axis is in its home position. + + + + + + + axis is in motion. + + + + + + + axis has been moved to a fixed position and is being maintained in + that position either electrically or mechanically. Action is + required to release the axis from this position. + + + + + + + axis is stopped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Controlled vocabulary for ChuckInterlock + + + + + + + chuck cannot be unclamped. + + + + + + + chuck can be unclamped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Controlled vocabulary for ChuckState + + + + + + + {{block(Chuck)}} is open to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Controlled vocabulary for ControllerMode + + + + + + + {{block(Controller)}} is configured to automatically execute a + program. + + + + + + + {{block(Controller)}} is not executing an active program. It is + capable of receiving instructions from an external source – + typically an operator. The {{block(Controller)}} executes operations + based on the instructions received from the external source. + + + + + + + operator can enter a series of operations for the + {{block(Controller)}} to perform. The {{block(Controller)}} will + execute this specific series of operations and then stop. + + + + + + + {{block(Controller)}} is operating in a mode that restricts the + active program from processing its next process step without + operator intervention. + + + + + + + {{block(Controller)}} is currently functioning as a programming + device and is not capable of executing an active program. + + + + + + + axes of the device are commanded to stop, but the spindle continues + to function. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Controlled vocabulary for ControllerModeOverride + + + + + + + {{block(ControllerModeOverride)}} is in the `ON` state and the mode + override is active. + + + + + + + {{block(ControllerModeOverride)}} is in the `OFF` state and the mode + override is inactive. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Controlled vocabulary for Direction + + + + + + + clockwise rotation using the right-hand rule. + + + + + + + counter-clockwise rotation using the right-hand rule. + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + Controlled vocabulary for DoorState + + + + + + + {{block(Door)}} is open to the point of a positive confirmation. + + + + + + + {{block(Door)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Door)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + Controlled vocabulary for EmergencyStop + + + + + + + emergency stop circuit is complete and the piece of equipment, + component, or composition is allowed to operate. + + + + + + + operation of the piece of equipment, component, or composition is + inhibited. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Controlled vocabulary for EndOfBar + + + + + + + {{block(EndOfBar)}} has been reached. + + + + + + + {{block(EndOfBar)}} has not been reached. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + Controlled vocabulary for EquipmentMode + + + + + + + equipment is functioning in the mode designated by the `subType`. + + + + + + + equipment is not functioning in the mode designated by the + `subType`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Controlled vocabulary for Execution + + + + + + + {{block(Component)}} is ready to execute instructions. It is + currently idle. + + + + + + + {{block(Component)}} is actively executing an instruction. + + + + + + + {{block(Component)}} suspends the execution of the program due to an + external signal. Action is required to resume execution. + + + + + + + motion of the active axes are commanded to stop at their current + position. + + + + + + + {{block(Component)}} program is not `READY` to execute. + + + + + + + command from the program has intentionally interrupted execution. + The {{block(Component)}} **MAY** have another state that indicates + if the execution is interrupted or the execution ignores the + interrupt instruction. + + + + + + + command from the program has intentionally interrupted execution. + Action is required to resume execution. + + + + + + + program completed execution. + + + + + + + {{block(Component)}} suspends execution while a secondary operation + executes. Execution resumes automatically once the secondary + operation completes. + + + + + + + program has been intentionally optionally stopped using an M01 or + similar code. **DEPRECATED** in *version 1.4* and replaced with + `OPTIONAL_STOP`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + Controlled vocabulary for FunctionalMode + + + + + + + {{block(Component)}} is currently producing product, ready to + produce product, or its current intended use is to be producing + product. + + + + + + + {{block(Component)}} is not currently producing product. It is being + prepared or modified to begin production of product. + + + + + + + {{block(Component)}} is not currently producing product. Typically, + it has completed the production of a product and is being modified + or returned to a neutral state such that it may then be prepared to + begin production of a different product. + + + + + + + {{block(Component)}} is not currently producing product. It is + currently being repaired, waiting to be repaired, or has not yet + been returned to a normal production status after maintenance has + been performed. + + + + + + + {{block(Component)}} is being used to prove-out a new process, + testing of equipment or processes, or any other active use that does + not result in the production of product. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + Controlled vocabulary for PartDetect + + + + + + + part or work piece is detected or is present. + + + + + + + part or work piece is not detected or is not present. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for PathMode + + + + + + + path is operating independently and without the influence of another + path. + + + + + + + path provides information or state values that influences the + operation of other {{block(DataItem)}} of similar type. + + + + + + + physical or logical parts which are not physically connected to each + other but are operating together. + + + + + + + axes associated with the path are mirroring the motion of the + `MASTER` path. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + Controlled vocabulary for PowerState + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is present and + active. + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is not present + or is disconnected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + Controlled vocabulary for PowerStatus + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Controlled vocabulary for ProgramEdit + + + + + + + {{block(Controller)}} is in the program edit mode. + + + + + + + {{block(Controller)}} is capable of entering the program edit mode + and no function is inhibiting a change to that mode. + + + + + + + {{block(Controller)}} is being inhibited by a function from entering + the program edit mode. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Controlled vocabulary for ProgramLocationType + + + + + + + managed by the controller. + + + + + + + not managed by the controller. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Controlled vocabulary for RotaryMode + + + + + + + axis is functioning as a spindle. + + + + + + + axis is configured to index. + + + + + + + position of the axis is being interpolated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Controlled vocabulary for SpindleInterlock + + + + + + + power has been removed and the spindle cannot be operated. + + + + + + + spindle has not been deactivated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + {{def(EventEnum::USER)}} + + + + + + + + + + {{def(EventEnum::USER)}} + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + Controlled vocabulary for WaitState + + + + + + + execution is waiting while the equipment is powering up and is not + currently available to begin producing parts or products. + + + + + + + execution is waiting while the equipment is powering down but has + not fully reached a stopped state. + + + + + + + execution is waiting while one or more discrete workpieces are being + loaded. + + + + + + + execution is waiting while one or more discrete workpieces are being + unloaded. + + + + + + + execution is waiting while a tool or tooling is being loaded. + + + + + + + execution is waiting while a tool or tooling is being unloaded. + + + + + + + execution is waiting while material is being loaded. + + + + + + + execution is waiting while material is being unloaded. + + + + + + + execution is waiting while another process is completed before the + execution can resume. + + + + + + + execution is waiting while the equipment is pausing but the piece of + equipment has not yet reached a fully paused state. + + + + + + + execution is waiting while the equipment is resuming the production + cycle but has not yet resumed execution. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Controlled vocabulary for PartStatus + + + + + + + part conforms to given requirements. + + + + + + + part does not conform to some given requirements. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Controlled vocabulary for ConnectionStatus + + + + + + + no connection at all. + + + + + + + {{term(agent)}} is waiting for a connection request from an + {{term(adapter)}}. + + + + + + + open connection. The normal state for the data transfer phase of the + connection. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Controlled vocabulary for PartProcessingState + + + + + + + part occurrence is not actively being processed, but the processing + has not ended. Processing requirements exist that have not yet been + fulfilled. This is the default entry state when the part occurrence + is originally received. In some cases, the part occurrence may + return to this state while it waits for additional processing to be + performed. + + + + + + + part occurrence is actively being processed. + + + + + + + part occurrence is no longer being processed. A general state when + the reason for termination is unknown. + + + + + + + part occurrence has completed processing successfully. + + + + + + + process has been stopped during the processing. The part occurrence + will require special treatment. + + + + + + + processing of the part occurrence has come to a premature end. + + + + + + + terminal state when the part occurrence has been removed from the + equipment by an external entity and it no longer exists at the + equipment. + + + + + + + part occurrence has been skipped for processing on the piece of + equipment. + + + + + + + part occurrence has been processed completely. However, the + processing may have a problem. + + + + + + + part occurrence is waiting for transit. + + + + + + + part occurrence is being transported to its destination. + + + + + + + part occurrence has been placed at its designated destination. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Controlled vocabulary for ProcessState + + + + + + + device is preparing to execute the process occurrence. + + + + + + + process occurrence is ready to be executed. + + + + + + + process occurrence is actively executing. + + + + + + + process occurrence is now finished. + + + + + + + process occurrence has been stopped and may be resumed. + + + + + + + process occurrence has come to a premature end and cannot be + resumed. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Controlled vocabulary for ValveState + + + + + + + {{block(ValveState)}} where flow is allowed and the aperture is + static. > Note: For a binary value, `OPEN` indicates the valve + has the maximum possible aperture. + + + + + + + valve is transitioning from a `CLOSED` state to an `OPEN` state. + + + + + + + {{block(ValveState)}} where flow is not possible, the aperture is + static, and the valve is completely shut. + + + + + + + valve is transitioning from an `OPEN` state to a `CLOSED` state. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + Controlled vocabulary for LockState + + + + + + + mechanism is engaged and preventing the associated + {{block(Component)}} from being opened or operated. + + + + + + + mechanism is disengaged and the associated {{block(Component)}} is + able to be opened or operated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Controlled vocabulary for OperatingMode + + + + + + + automatically execute instructions from a recipe or program. > + Note: Setpoint comes from a recipe. + + + + + + + execute instructions from an external agent or person. > Note 1 + to entry: Valve or switch is manipulated by an agent/person. > + Note 2 to entry: Direct control of the PID output. % of the range: A + user manually sets the % output, not the setpoint. + + + + + + + executes a single instruction from a recipe or program. > Note 1 + to entry: Setpoint is entered and fixed, but the PID is controlling. + > Note 2 to entry: Still goes through the PID control system. + > Note 3 to entry: Manual fixed entry from a recipe. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Controlled vocabulary for PartCountType + + + + + + + count is of individual items. + + + + + + + pre-specified group of items. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + Controlled vocabulary for LeakDetect + + + + + + + leak is currently being detected. + + + + + + + leak is currently not being detected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Controlled vocabulary for BatteryState + + + + + + + {{block(Component)}} is at it's maximum rated charge level. + + + + + + + {{block(Component)}}'s charge is increasing. + + + + + + + {{block(Component)}}'s charge is decreasing. + + + + + + + {{block(Component)}} is at it's minimum charge level. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Controlled vocabulary for CharacteristicStatus + + + + + + + measurement is within acceptable tolerances. + + + + + + + measurement is not within acceptable tolerances. + + + + + + + failed, but acceptable constraints achievable by utilizing + additional manufacturing processes. + + + + + + + measurement is indeterminate due to an equipment failure. + + + + + + + measurement cannot be determined. + + + + + + + measurement cannot be evaluated. + + + + + + + nominal provided without tolerance limits. {{cite(QIF 3:2018 + 5.10.2.6)}} + + + + + + + status of measurement cannot be determined. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Controlled vocabulary for UncertaintyType + + + + + + + {{term(combined standard uncertainty)}}. + + + + + + + {{term(standard uncertainty)}} using arithmetic mean or average the + observations. {{cite(JCGM 100:2008 4.2)}} + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Controlled vocabulary for InterfaceState + + + + + + + {{block(Interface)}} is currently operational and performing as + expected. + + + + + + + {{block(Interface)}} is currently not operational. + + + + + + + Value is indeterminate + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + Constraints for Entry Values + + + + + + the key + + + + + + + an indicatore that the entry has been removed + + + + + + + + Constraints for Entry Values + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + DataSet of Example + + + + + + + + + + + + + + DataSet of Example + + + + + + + DataSet of Example + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of Example + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + DataSet of Description + + + + + + + + + + + + + + DataSet of Description + + + + + + + DataSet of Description + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of Description + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + A cell of a table + + + + + + the key + + + + + + + + A cell of a table + + + + + + + {{term(key-value pair)}} published as part of a {{block(Table)}}. > + Note: In the {{term(XML)}} representation, {{block(TableEntry)}} + **MUST** appear as {{block(Entry)}}. + + + + + + + + + + + + + + {{term(key-value pair)}} published as part of a {{block(Table)}}. > + Note: In the {{term(XML)}} representation, {{block(TableEntry)}} + **MUST** appear as {{block(Entry)}}. + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Cell of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Table of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Table Entry of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + Cell of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + Table of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + Cell of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + Table of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + Table Entry of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Cell of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Table of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Table Entry of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AVAILABILITY)}} + + + + + + + Cell of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AVAILABILITY)}} + + + + + + + Table of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AVAILABILITY)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + Cell of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + Table of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Cell of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Table of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Cell of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Table of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_STATE)}} + + + + + + + Cell of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_STATE)}} + + + + + + + Table of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::BLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::BLOCK)}} + + + + + + + Cell of {{def(EventEnum::BLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::BLOCK)}} + + + + + + + Table of {{def(EventEnum::BLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::BLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Cell of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Table of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Cell of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Table of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + Cell of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + Table of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::CODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CODE)}} + + + + + + + Cell of {{def(EventEnum::CODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CODE)}} + + + + + + + Table of {{def(EventEnum::CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CODE)}} + + + + + + + Table Entry of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Cell of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Table of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + Table Entry of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + Cell of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + Table of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + Table Entry of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DATE_CODE)}} + + + + + + + Cell of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DATE_CODE)}} + + + + + + + Table of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DATE_CODE)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Table of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Table Entry of {{def(EventEnum::DIRECTION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DIRECTION)}} + + + + + + + Cell of {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DIRECTION)}} + + + + + + + Table of {{def(EventEnum::DIRECTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DIRECTION)}} + + + + + + + Table Entry of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DOOR_STATE)}} + + + + + + + Cell of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DOOR_STATE)}} + + + + + + + Table of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DOOR_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Cell of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Table of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Table Entry of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::END_OF_BAR)}} + + + + + + + Cell of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::END_OF_BAR)}} + + + + + + + Table of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::END_OF_BAR)}} + + + + + + + Table Entry of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Cell of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Table of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::EXECUTION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::EXECUTION)}} + + + + + + + Cell of {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::EXECUTION)}} + + + + + + + Table of {{def(EventEnum::EXECUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::EXECUTION)}} + + + + + + + Table Entry of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + Cell of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + Table of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::HARDNESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::HARDNESS)}} + + + + + + + Cell of {{def(EventEnum::HARDNESS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::HARDNESS)}} + + + + + + + Table of {{def(EventEnum::HARDNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::HARDNESS)}} + + + + + + + Table Entry of {{def(EventEnum::LINE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LINE)}} + + + + + + + Cell of {{def(EventEnum::LINE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LINE)}} + + + + + + + Table of {{def(EventEnum::LINE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LINE)}} + + + + + + + Table Entry of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LINE_LABEL)}} + + + + + + + Cell of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LINE_LABEL)}} + + + + + + + Table of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LINE_LABEL)}} + + + + + + + Table Entry of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + Table of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + Table Entry of {{block(Resource)}} composed of material that is consumed + or used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{block(Resource)}} composed of material that is consumed + or used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + Cell of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + + + + + + Cell of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + Table of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + Table Entry of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + Cell of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + Table of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + Table Entry of {{def(EventEnum::MESSAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MESSAGE)}} + + + + + + + Cell of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MESSAGE)}} + + + + + + + Table of {{def(EventEnum::MESSAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MESSAGE)}} + + + + + + + Table Entry of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + Cell of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + Table of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PALLET_ID)}} + + + + + + + Cell of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PALLET_ID)}} + + + + + + + Table of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PALLET_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT)}} + + + + + + + Cell of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_COUNT)}} + + + + + + + Table of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_DETECT)}} + + + + + + + Cell of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_DETECT)}} + + + + + + + Table of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_DETECT)}} + + + + + + + Table Entry of {{def(EventEnum::PART_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_ID)}} + + + + + + + Cell of {{def(EventEnum::PART_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_ID)}} + + + + + + + Table of {{def(EventEnum::PART_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_NUMBER)}} + + + + + + + Table of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_NUMBER)}} + + + + + + + Table Entry of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Cell of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Table of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Table Entry of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PATH_MODE)}} + + + + + + + Cell of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PATH_MODE)}} + + + + + + + Table of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PATH_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::POWER_STATE)}} + + + + + + + Cell of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::POWER_STATE)}} + + + + + + + Table of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::POWER_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::POWER_STATUS)}} + + + + + + + Cell of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::POWER_STATUS)}} + + + + + + + Table of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::POWER_STATUS)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + Table of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM)}} + + + + + + + Table of {{def(EventEnum::PROGRAM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial + value is not defined, the nesting level associated with the highest or + initial nesting level of the program **MUST** default to zero (0). + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial + value is not defined, the nesting level associated with the highest or + initial nesting level of the program **MUST** default to zero (0). + + + + + + + Cell of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Table of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Table Entry of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + Cell of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + Table of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + Cell of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + + + + + Cell of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + Table of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + Table Entry of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Table of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Table Entry of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + Cell of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + Table of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Cell of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Table of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + Cell of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + Table of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_ID)}} + + + + + + + Cell of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_ID)}} + + + + + + + Table of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_ID)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Table of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + Cell of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + Table of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + Table Entry of {{def(EventEnum::USER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::USER)}} + + + + + + + Cell of {{def(EventEnum::USER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::USER)}} + + + + + + + Table of {{def(EventEnum::USER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::USER)}} + + + + + + + Table Entry of {{def(EventEnum::VARIABLE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::VARIABLE)}} + + + + + + + Cell of {{def(EventEnum::VARIABLE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::VARIABLE)}} + + + + + + + Table of {{def(EventEnum::VARIABLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::VARIABLE)}} + + + + + + + Table Entry of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + Cell of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + + + + + + Cell of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + Table of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + Table Entry of leaf {{block(Component)}} composed of a string like piece + or filament of relatively rigid or flexible material provided in a + variety of diameters. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of leaf {{block(Component)}} composed of a string like piece + or filament of relatively rigid or flexible material provided in a + variety of diameters. + + + + + + + Cell of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + + + + + + Cell of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + Table of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + Table Entry of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + Cell of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + Table of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + Table Entry of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + Cell of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + Table of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + Table Entry of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + Cell of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + Table of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + Table Entry of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FIRMWARE)}} + + + + + + + Cell of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FIRMWARE)}} + + + + + + + Table of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FIRMWARE)}} + + + + + + + Table Entry of {{def(EventEnum::APPLICATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::APPLICATION)}} + + + + + + + Cell of {{def(EventEnum::APPLICATION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::APPLICATION)}} + + + + + + + Table of {{def(EventEnum::APPLICATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::APPLICATION)}} + + + + + + + Table Entry of {{def(EventEnum::LIBRARY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LIBRARY)}} + + + + + + + Cell of {{def(EventEnum::LIBRARY)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LIBRARY)}} + + + + + + + Table of {{def(EventEnum::LIBRARY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LIBRARY)}} + + + + + + + Table Entry of {{def(EventEnum::HARDWARE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::HARDWARE)}} + + + + + + + Cell of {{def(EventEnum::HARDWARE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::HARDWARE)}} + + + + + + + Table of {{def(EventEnum::HARDWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::HARDWARE)}} + + + + + + + Table Entry of {{def(EventEnum::NETWORK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::NETWORK)}} + + + + + + + Cell of {{def(EventEnum::NETWORK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::NETWORK)}} + + + + + + + Table of {{def(EventEnum::NETWORK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::NETWORK)}} + + + + + + + Table Entry of rotations about X, Y, and Z axes are expressed in A, B, + and C respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of rotations about X, Y, and Z axes are expressed in A, B, + and C respectively within a 3-dimensional vector. + + + + + + + Cell of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + + + + + Cell of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + Table of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + Table Entry of translations along X, Y, and Z axes are expressed as x,y, + and z respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of translations along X, Y, and Z axes are expressed as x,y, + and z respectively within a 3-dimensional vector. + + + + + + + Cell of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + + + + + + Cell of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + Table of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + Table Entry of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Table of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + Cell of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + Table of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + Table Entry of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + Cell of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + Table of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + Table of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Cell of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + Cell of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + Table of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + Table of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + Table of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + Table Entry of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Cell of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Table of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Table Entry of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + Cell of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + Table of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + Cell of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + Table of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + Table Entry of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + Cell of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + Table of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + Table Entry of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + Cell of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + Table of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + Table of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + Table Entry of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + Cell of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + Table of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + Table of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Cell of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table Entry of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Cell of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table Entry of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + Cell of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + Table of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + Cell of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + Table of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + Cell of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + Table of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Cell of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Table of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Cell of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Table of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Table of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::VALVE_STATE)}} + + + + + + + Cell of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::VALVE_STATE)}} + + + + + + + Table of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::VALVE_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCK_STATE)}} + + + + + + + Cell of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCK_STATE)}} + + + + + + + Table of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCK_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + Cell of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + Table of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Cell of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Table of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + Cell of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + Table of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + Cell of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + Table of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + Cell of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + + + + + Cell of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + Table of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + Table Entry of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Cell of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Table of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + Cell of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + Table of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + Table Entry of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + Cell of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + Table of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + Table Entry of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + Cell of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + Table of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + Table Entry of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::HOST_NAME)}} + + + + + + + Cell of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::HOST_NAME)}} + + + + + + + Table of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::HOST_NAME)}} + + + + + + + Table Entry of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Cell of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Table of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Table Entry of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + Cell of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + Table of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + Cell of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + Table of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + Table Entry of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + Cell of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + Table of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + Table Entry of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + Cell of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + + + + + + Cell of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + Table of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + Cell of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + + + + + Cell of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + Table of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + Cell of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + + + + + Cell of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + Table of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + Cell of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + + + + + Cell of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + Table of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + Table of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + Table of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Table of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + Table of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + Table of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + Table Entry of See {{sect(AlarmLimits)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of See {{sect(AlarmLimits)}}. + + + + + + + Cell of See {{sect(AlarmLimits)}}. + + + + + + + + + + + + + + Cell of See {{sect(AlarmLimits)}}. + + + + + + + Table of See {{sect(AlarmLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of See {{sect(AlarmLimits)}}. + + + + + + + Table Entry of See {{sect(ControlLimits)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of See {{sect(ControlLimits)}}. + + + + + + + Cell of See {{sect(ControlLimits)}}. + + + + + + + + + + + + + + Cell of See {{sect(ControlLimits)}}. + + + + + + + Table of See {{sect(ControlLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of See {{sect(ControlLimits)}}. + + + + + + + Table Entry of See {{sect(SpecificationLimits)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of See {{sect(SpecificationLimits)}}. + + + + + + + Cell of See {{sect(SpecificationLimits)}}. + + + + + + + + + + + + + + Cell of See {{sect(SpecificationLimits)}}. + + + + + + + Table of See {{sect(SpecificationLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of See {{sect(SpecificationLimits)}}. + + + + + + + Table Entry of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + Cell of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + Table of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + Table Entry of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + Cell of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + Table of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + Cell of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + Table of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + Table Entry of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + Cell of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + Table of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + Table Entry of {{def(EventEnum::THICKNESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::THICKNESS)}} + + + + + + + Cell of {{def(EventEnum::THICKNESS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::THICKNESS)}} + + + + + + + Table of {{def(EventEnum::THICKNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::THICKNESS)}} + + + + + + + Table Entry of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + Cell of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + Table of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + Cell of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + Table of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Cell of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Table of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Table Entry of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ACCELERATION)}} + + + + + + + Cell of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ACCELERATION)}} + + + + + + + Table of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ACCELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Cell of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Table of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE)}} + + + + + + + Cell of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AMPERAGE)}} + + + + + + + Table of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AMPERAGE)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGLE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGLE)}} + + + + + + + Cell of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGLE)}} + + + + + + + Table of {{def(SampleEnum::ANGLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGLE)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Cell of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Table of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Cell of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Table of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Table Entry of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Cell of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Table of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Cell of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Table of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Cell of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Table of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Table Entry of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Cell of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Table of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Table Entry of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Cell of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Table of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Table Entry of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Cell of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Table of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Table Entry of {{def(SampleEnum::DENSITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DENSITY)}} + + + + + + + Cell of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DENSITY)}} + + + + + + + Table of {{def(SampleEnum::DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DENSITY)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Table Entry of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Cell of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Table of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Table Entry of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Cell of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Table of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Table Entry of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Cell of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Table of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Table Entry of {{def(SampleEnum::FLOW)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FLOW)}} + + + + + + + Cell of {{def(SampleEnum::FLOW)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FLOW)}} + + + + + + + Table of {{def(SampleEnum::FLOW)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FLOW)}} + + + + + + + Table Entry of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FREQUENCY)}} + + + + + + + Cell of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FREQUENCY)}} + + + + + + + Table of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FREQUENCY)}} + + + + + + + Table Entry of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Cell of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Table of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Table Entry of {{def(SampleEnum::LENGTH)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LENGTH)}} + + + + + + + Cell of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LENGTH)}} + + + + + + + Table of {{def(SampleEnum::LENGTH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LENGTH)}} + + + + + + + Table Entry of {{def(SampleEnum::LEVEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LEVEL)}} + + + + + + + Cell of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LEVEL)}} + + + + + + + Table of {{def(SampleEnum::LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LEVEL)}} + + + + + + + Table Entry of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Cell of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Table of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Table Entry of {{def(SampleEnum::LOAD)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LOAD)}} + + + + + + + Cell of {{def(SampleEnum::LOAD)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LOAD)}} + + + + + + + Table of {{def(SampleEnum::LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LOAD)}} + + + + + + + Table Entry of {{def(SampleEnum::MASS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::MASS)}} + + + + + + + Cell of {{def(SampleEnum::MASS)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::MASS)}} + + + + + + + Table of {{def(SampleEnum::MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::MASS)}} + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Table Entry of Example + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of Example + + + + + + + Cell of Example + + + + + + + + + + + + + + Cell of Example + + + + + + + Table of Example + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of Example + + + + + + + Table Entry of {{def(SampleEnum::PH)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PH)}} + + + + + + + Cell of {{def(SampleEnum::PH)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PH)}} + + + + + + + Table of {{def(SampleEnum::PH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PH)}} + + + + + + + Table Entry of {{def(SampleEnum::POSITION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::POSITION)}} + + + + + + + Cell of {{def(SampleEnum::POSITION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::POSITION)}} + + + + + + + Table of {{def(SampleEnum::POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::POSITION)}} + + + + + + + Table Entry of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Cell of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Table of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Table Entry of Description + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of Description + + + + + + + Cell of Description + + + + + + + + + + + + + + Cell of Description + + + + + + + Table of Description + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of Description + + + + + + + Table Entry of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Cell of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Table of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Table Entry of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::RESISTANCE)}} + + + + + + + Cell of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::RESISTANCE)}} + + + + + + + Table of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::RESISTANCE)}} + + + + + + + Table Entry of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Cell of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Table of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Table Entry of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Cell of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Table of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Table Entry of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Cell of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Table of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Table Entry of {{def(SampleEnum::STRAIN)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::STRAIN)}} + + + + + + + Cell of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::STRAIN)}} + + + + + + + Table of {{def(SampleEnum::STRAIN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::STRAIN)}} + + + + + + + Table Entry of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Cell of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Table of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Table Entry of {{def(SampleEnum::TENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TENSION)}} + + + + + + + Cell of {{def(SampleEnum::TENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TENSION)}} + + + + + + + Table of {{def(SampleEnum::TENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::TILT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TILT)}} + + + + + + + Cell of {{def(SampleEnum::TILT)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TILT)}} + + + + + + + Table of {{def(SampleEnum::TILT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TILT)}} + + + + + + + Table Entry of {{def(SampleEnum::TORQUE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TORQUE)}} + + + + + + + Cell of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TORQUE)}} + + + + + + + Table of {{def(SampleEnum::TORQUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TORQUE)}} + + + + + + + Table Entry of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VELOCITY)}} + + + + + + + Cell of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VELOCITY)}} + + + + + + + Table of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VELOCITY)}} + + + + + + + Table Entry of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VISCOSITY)}} + + + + + + + Cell of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VISCOSITY)}} + + + + + + + Table of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VISCOSITY)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE)}} + + + + + + + Cell of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLTAGE)}} + + + + + + + Table of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLTAGE)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Cell of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Table of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Cell of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Table of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Table Entry of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::WATTAGE)}} + + + + + + + Cell of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::WATTAGE)}} + + + + + + + Table of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::WATTAGE)}} + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Table of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Table of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Table of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Table of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Table Entry of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Cell of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Table of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Cell of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Table of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Cell of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Table of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DIAMETER)}} + + + + + + + Cell of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DIAMETER)}} + + + + + + + Table of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DIAMETER)}} + + + + + + + Table Entry of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ORIENTATION)}} + + + + + + + Cell of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ORIENTATION)}} + + + + + + + Table of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ORIENTATION)}} + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Table of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Table of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Table of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Table Entry of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Cell of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Table of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DECELERATION)}} + + + + + + + Cell of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DECELERATION)}} + + + + + + + Table of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DECELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Table of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Cell of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Table of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Table of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Table Entry of The force per unit area measured relative to a vacuum. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of The force per unit area measured relative to a vacuum. + + + + + + + Cell of The force per unit area measured relative to a vacuum. + + + + + + + + + + + + + + Cell of The force per unit area measured relative to a vacuum. + + + + + + + Table of The force per unit area measured relative to a vacuum. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of The force per unit area measured relative to a vacuum. + + + + + + + Table Entry of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::OPENNESS)}} + + + + + + + Cell of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::OPENNESS)}} + + + + + + + Table of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::OPENNESS)}} + + + + + + + Table Entry of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEW_POINT)}} + + + + + + + Cell of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEW_POINT)}} + + + + + + + Table of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEW_POINT)}} + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Cell of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Table of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Table Entry of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Table of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Table of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Cell of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Table of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table Entry of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + Cell of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + Table of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + The description of the Condition + + + + + + + + The device's severity + + + + + + + + Identifier of an individual condition activation provided by a piece of + equipment + + + + + + + + A qualifier for the condition + + + + + + + The value is too high + + + + + + + The value is too low + + + + + + + + + Description + + + + + + + + + type of the power source. + + + + + + + The component specific Notifcation code + + + + + + + The component specific Notifcation code + + + + + + + An optional attribute that helps qualify the condition + + + + + + + The statistical operation on this data + + + + + + + + + + Description + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + + Identifier of an individual condition activation provided by a + piece of equipment + + + + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + The conditon can not be determined. + + + + + + + + + + The conditon can not be determined. + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + DEPRECATED: An Notifcation code as defined by the component + + + + + + + + DEPRECATED: Types of Notifcations + + + + + + + A failure + + + + + + + A fault occurred + + + + + + + A spindle crash + + + + + + + A component has jammed + + + + + + + The component has been overloaded + + + + + + + E-Stop was pushed + + + + + + + A material failure has occurred + + + + + + + An operators message. Used with INFO severity + + + + + + + Another Notifcation type + + + + + + + + + DEPRECATED: The active or cleared state of the notification + + + + + + + The notification is active + + + + + + + The notification has been cleared + + + + + + + + + level of severity on a scale of 1-10. + + + + + + + The notification is critical + + + + + + + An error has occurred + + + + + + + A medium level notification that should be observed + + + + + + + This notification is for information purposes only + + + + + + + + + {{def(EventEnum::ALARM)}} + + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + level of severity on a scale of 1-10. + + + + + + + The state + + + + + + + The component specific Notifcation code + + + + + + + + + + {{def(EventEnum::ALARM)}} + + + + + + + The possible values for an interface event + + + + + + + The value is unavailable + + + + + + + The interface is not ready + + + + + + + The interface is ready + + + + + + + The interface is actively executing + + + + + + + The interface has completed the action + + + + + + + The interface action has failed + + + + + + + + + An abstract interface event + + + + + + + + + + + + + + An abstract interface event + + + + + + + The state of the interface + + + + + + + The value is unavailable + + + + + + + The interface is enabled + + + + + + + The interface is disabled + + + + + + \ No newline at end of file diff --git a/schemas/MTConnectStreams_2.4_1.0.xsd b/schemas/MTConnectStreams_2.4_1.0.xsd new file mode 100644 index 00000000..aa858ba3 --- /dev/null +++ b/schemas/MTConnectStreams_2.4_1.0.xsd @@ -0,0 +1,46137 @@ + + + + + + + root entity of an {{term(MTConnectStreams Response Document)}} that + contains the {{term(Observation Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectStreams](figures/MTConnectStreams.png + "MTConnectStreams"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectStreams)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + The sender of the message + + + + + + + + The date and time the document was created + + + + + + + + A sequence number + + + + + + + + + + + A debugging flag for testing. + + + + + + + + The instance number of the agent, used for fault tolerance + + + + + + + + + + + The size of the agents buffer + + + + + + + + + + + The time the sample was reported + + + + + + + + The time a sample occurred + + + + + + + + A version number + + + + + + + + A short name for any element + + + + + + + + A universally unique id that uniquely identifies the element for + it's entire life + + + + + + + + A serial number for a piece of equipment + + + + + + + + The measurement source + + + + + + + + A sample rate in milliseconds per sample + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + + An identifier + + + + + + + + The number significant digits + + + + + + + + The item's reference to the Device model composition + + + + + + + + A length of time in seconds + + + + + + + + A flag indicating the item has been removed + + + + + + + + The key for adata set + + + + + + + + A timestamp in 8601 format of the last update of the Device information + for any device + + + + + + + + The unique id of the asset + + + + + + + + An asset type + + + + + + + + The maximum number of assets + + + + + + + + + + + The number of assets + + + + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + The limit of a value + + + + + + + + Common floating point sample value + + + + + + + + + + + + A three dimensional value 'X Y Z' or 'A B C' + + + + + + + + + + + A description + + + + + + + + Extended tyoe for The types of measurements available + + + + + + + + + + The types of measurements available + + + + + + + positive rate of change of velocity. + + + + + + + accumulated time for an activity or event. + + + + + + + strength of electrical current. **DEPRECATED** in *Version 1.6*. + Replaced by `AMPERAGE_AC` and `AMPERAGE_DC`. + + + + + + + angular position. + + + + + + + positive rate of change of angular velocity. + + + + + + + rate of change of angular position. + + + + + + + feedrate of a linear axis. + + + + + + + fluid capacity of an object or container. + + + + + + + geometric capacity of an object or container. + + + + + + + percentage of one component within a mixture of components. + + + + + + + ability of a material to conduct electricity. + + + + + + + speed difference (relative velocity) between the cutting mechanism + and the surface of the workpiece it is operating on. + + + + + + + volumetric mass of a material per unit volume of that material. + + + + + + + rate of change in spatial volume of material deposited in an + additive manufacturing process. + + + + + + + density of the material deposited in an additive manufacturing + process per unit of volume. + + + + + + + mass of the material deposited in an additive manufacturing process. + + + + + + + rate at which a spatial volume of material is deposited in an + additive manufacturing process. + + + + + + + spatial volume of material to be deposited in an additive + manufacturing process. + + + + + + + change in position of an object. + + + + + + + {{block(Wattage)}} used or generated by a component over an interval + of time. + + + + + + + amount of time a piece of equipment or a sub-part of a piece of + equipment has performed specific activities. + + + + + + + amount of a substance remaining compared to the planned maximum + amount of that substance. + + + + + + + rate of flow of a fluid. + + + + + + + number of occurrences of a repeating event per unit time. + + + + + + + position in three-dimensional space. **DEPRECATED** in Version 1.1. + + + + + + + length of an object. + + + + + + + level of a resource. **DEPRECATED** in *Version 1.2*. See + `FILL_LEVEL`. + + + + + + + {{term(force)}} applied to a mass in one direction only. + + + + + + + actual versus the standard rating of a piece of equipment. + + + + + + + mass of an object(s) or an amount of material. + + + + + + + feedrate for the axes, or a single axis, associated with a + {{block(Path)}} component. + + + + + + + feedrate for the axes, or a single axis. + + + + + + + position of a control point associated with a {{block(Controller)}} + or a {{block(Path)}}. + + + + + + + acidity or alkalinity of a solution. + + + + + + + point along an axis in a {{term(cartesian coordinate system)}}. + + + + + + + ratio of real power flowing to a load to the apparent power in that + AC circuit. + + + + + + + force per unit area measured relative to atmospheric pressure. + Commonly referred to as gauge pressure. + + + + + + + amount of time a piece of equipment has performed different types of + activities associated with the process being performed at that piece + of equipment. + + + + + + + degree to which a substance opposes the passage of an electric + current. + + + + + + + rotational speed of a rotary axis. + + + + + + + sound level or sound pressure level relative to atmospheric + pressure. + + + + + + + rotational speed of the rotary axis. **DEPRECATED** in *Version + 1.2*. Replaced by `ROTARY_VELOCITY`. + + + + + + + amount of deformation per unit length of an object when a load is + applied. + + + + + + + degree of hotness or coldness measured on a definite scale. + + + + + + + force that stretches or elongates an object. + + + + + + + angular displacement. + + + + + + + turning force exerted on an object or by an object. + + + + + + + rate of change of position of a {{block(Component)}}. + + + + + + + fluid's resistance to flow. + + + + + + + electrical potential between two points. **DEPRECATED** in *Version + 1.6*. Replaced by `VOLTAGE_AC` and `VOLTAGE_DC`. + + + + + + + apparent power in an electrical circuit, equal to the product of + root-mean-square (RMS) voltage and RMS current (commonly referred to + as VA). + + + + + + + reactive power in an AC electrical circuit (commonly referred to as + VAR). + + + + + + + fluid volume of an object or container. + + + + + + + geometric volume of an object or container. + + + + + + + power flowing through or dissipated by an electrical circuit or + piece of equipment. + + + + + + + electrical current that reverses direction at regular short + intervals. + + + + + + + electric current flowing in one direction only. + + + + + + + electrical potential between two points in an electrical circuit in + which the current periodically reverses direction. + + + + + + + electrical potential between two points in an electrical circuit in + which the current is unidirectional. + + + + + + + dimension of an entity relative to the X direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Y direction of the referenced + coordinate system. + + + + + + + dimension of an entity relative to the Z direction of the referenced + coordinate system. + + + + + + + dimension of a diameter. + + + + + + + angular position of a plane or vector relative to a {{term(cartesian + coordinate system)}} + + + + + + + amount of water vapor present expressed as a percent to reach + saturation at the same temperature. + + + + + + + amount of water vapor expressed in grams per cubic meter. + + + + + + + ratio of the water vapor present over the total weight of the water + vapor and air present expressed as a percent. + + + + + + + average rate of change of values for data items in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + average rate of change of values for assets in the MTConnect + streams. The average is computed over a rolling window defined by + the implementation. + + + + + + + change of pressure per unit time. + + + + + + + negative rate of change of velocity. + + + + + + + negative rate of change of angular velocity. + + + + + + + force per unit area measured relative to a vacuum. + + + + + + + percentage open where 100% is fully open and 0% is fully closed. + + + + + + + temperature at which moisture begins to condense, corresponding to + saturation for a given absolute humidity. + + + + + + + force relative to earth's gravity. + + + + + + + acceleration relative to Earth's gravity of 9.80665 + `METER/SECOND^2`. + + + + + + + maximum rated charge a battery is capable of maintaining based on + the battery discharging at a specified current over a specified time + period. + + + + + + + value of current being drawn from the {{block(Component)}}. + + + + + + + value of the current being supplied to the {{block(Component)}} for + the purpose of charging. + + + + + + + value of the battery's present capacity expressed as a + percentage of the battery's maximum rated capacity. + + + + + + + difference between actual and commanded position at the end of a + motion. + + + + + + + difference between actual and commanded position at any specific + point in time during a motion. + + + + + + + difference between the commanded encoder/resolver position, and the + actual encoder/resolver position when motion is complete. + + + + + + + angular difference between the commanded encoder/resolver position, + and the actual encoder/resolver position when motion is complete. + + + + + + + difference between the commanded encoder/resolver position and the + actual encoder/resolver position at any specified point in time + during a motion. + + + + + + + angular difference between the commanded encoder/resolver position + and the actual encoder/resolver position at any specified point in + time during a motion. + + + + + + + absolute value of the change in position along a vector. + + + + + + + absolute value of the change in angular position around a vector + + + + + + + point in a {{term(cartesian coordinate system)}}. + + + + + + + set of axes currently associated with a {{block(Path)}} or + {{block(Controller)}}. + + + + + + + operational state of an apparatus for moving or controlling a + mechanism or system. + + + + + + + **DEPRECATED:** Replaced with `CONDITION` category data items in + Version 1.1.0. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been added or + changed. + + + + + + + {{block(assetId)}} of the {{term(Asset)}} that has been removed. + + + + + + + {{term(agent)}}'s ability to communicate with the data source. + + + + + + + describes the way the axes will be associated to each other. This is + used in conjunction with `COUPLED_AXES` to indicate the way they are + interacting. + + + + + + + value of a signal or calculation issued to adjust the feedrate of an + individual linear type axis. + + + + + + + state of the axis lockout function when power has been removed and + the axis is allowed to move freely. + + + + + + + state of a {{block(Linear)}} or {{block(Rotary)}} component + representing an axis. + + + + + + + line of code or command being executed by a {{block(Controller)}} + entity. + + + + + + + total count of the number of blocks of program code that have been + executed since execution started. + + + + + + + state of an interlock function or control logic state intended to + prevent the associated {{block(Chuck)}} component from being + operated. + + + + + + + operating state of a mechanism that holds a part or stock material + during a manufacturing process. It may also represent a mechanism + that holds any other mechanism in place within a piece of equipment. + + + + + + + programmatic code being executed. **DEPRECATED** in *Version 1.1*. + + + + + + + operating state of a mechanism represented by a + {{block(Composition)}} entity. + + + + + + + current mode of the {{block(Controller)}} component. + + + + + + + setting or operator selection that changes the behavior of a piece + of equipment. + + + + + + + set of associated axes. + + + + + + + time and date code associated with a material or other physical + item. + + + + + + + identifier of another piece of equipment that is temporarily + associated with a component of this piece of equipment to perform a + particular function. + + + + + + + direction of motion. + + + + + + + operational state of a {{block(Door)}} component or composition + element. + + + + + + + state of the emergency stop signal for a piece of equipment, + controller path, or any other component or subsystem of a piece of + equipment. + + + + + + + indication of whether the end of a piece of bar stock being feed by + a bar feeder has been reached. + + + + + + + indication that a piece of equipment, or a sub-part of a piece of + equipment, is performing specific types of activities. + + + + + + + operating state of a {{block(Component)}}. + + + + + + + current intended production status of the {{block(Component)}}. + + + + + + + hardness of a material. + + + + + + + current line of code being executed. **DEPRECATED** in *Version + 1.4.0*. + + + + + + + identifier for a {{block(Block)}} of code in a {{block(Program)}}. + + + + + + + position of a block of program code within a control program. + + + + + + + identifier of a material used or consumed in the manufacturing + process. + + + + + + + identifies the layers of material applied to a part or product as + part of an additive manufacturing process. + + + + + + + information to be transferred from a piece of equipment to a client + software application. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + identifier for a pallet. + + + + + + + aggregate count of parts. + + + + + + + indication designating whether a part or work piece has been + detected or is present. + + + + + + + identifier of a part in a manufacturing operation. + + + + + + + identifier of a part or product moving through the manufacturing + process. **DEPRECATED** in *Version 1.7*. `PART_NUMBER` is now a + `subType` of `PART_KIND_ID`. + + + + + + + value of a signal or calculation issued to adjust the feedrate for + the axes associated with a {{block(Path)}} component that may + represent a single axis or the coordinated movement of multiple + axes. + + + + + + + describes the operational relationship between a {{block(Path)}} + entity and another {{block(Path)}} entity for pieces of equipment + comprised of multiple logical groupings of controlled axes or other + logical operations. + + + + + + + indication of the status of the source of energy for an entity to + allow it to perform its intended function or the state of an + enabling signal providing permission for the entity to perform its + functions. + + + + + + + status of the {{block(Component)}}. **DEPRECATED** in *Version + 1.1.0*. + + + + + + + time and date associated with an activity or event. + + + + + + + name of the logic or motion program being executed by the + {{block(Controller)}} component. + + + + + + + comment or non-executable statement in the control program. + + + + + + + indication of the status of the {{block(Controller)}} components + program editing mode. A program may be edited while another is + executed. + + + + + + + name of the program being edited. This is used in conjunction with + {{block(ProgramEdit)}} when in `ACTIVE` state. + + + + + + + non-executable header section of the control program. + + + + + + + {{term(URI)}} for the source file associated with + {{block(Program)}}. + + + + + + + defines whether the logic or motion program defined by + {{block(Program)}} is being executed from the local memory of the + controller or from an outside source. + + + + + + + indication of the nesting level within a control program that is + associated with the code or instructions that is currently being + executed. + + + + + + + current operating mode for a {{block(Rotary)}} type axis. + + + + + + + percentage change to the velocity of the programmed velocity for a + {{block(Rotary)}} axis. + + + + + + + serial number associated with a {{block(Component)}}, + {{block(Asset)}}, or {{block(Device)}}. + + + + + + + indication of the status of the spindle for a piece of equipment + when power has been removed and it is free to rotate. + + + + + + + identifier of an individual tool asset. + + + + + + + identifier for the tool group associated with a specific tool. + Commonly used to designate spare tools. + + + + + + + identifier of the tool currently in use for a given `Path`. + **DEPRECATED** in *Version 1.2.0*. See `TOOL_ASSET_ID`. + + + + + + + identifier assigned by the {{block(Controller)}} component to a + cutting tool when in use by a piece of equipment. + + + + + + + reference to the tool offset variables applied to the active cutting + tool. + + + + + + + identifier of the person currently responsible for operating the + piece of equipment. + + + + + + + data whose meaning may change over time due to changes in the + operation of a piece of equipment or the process being executed on + that piece of equipment. + + + + + + + indication of the reason that {{block(Execution)}} is reporting a + value of `WAIT`. + + + + + + + identifier for the type of wire used as the cutting mechanism in + Electrical Discharge Machining or similar processes. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. **DEPRECATION WARNING**: Recommend using + `FIXTURE_ID` instead. + + + + + + + reference to offset variables for a work piece or part. + + + + + + + Operating System (OS) of a {{block(Component)}}. + + + + + + + embedded software of a {{block(Component)}} . + + + + + + + application on a {{block(Component)}}. + + + + + + + software library on a {{block(Component)}} + + + + + + + hardware of a {{block(Component)}}. + + + + + + + network details of a {{block(Component)}}. + + + + + + + three space angular displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + three space linear displacement of an object or coordinate system + relative to a {{term(cartesian coordinate system)}}. + + + + + + + {{term(UUID)}} of new device added to an {{term(MTConnect Agent)}}. + + + + + + + {{term(UUID)}} of a device removed from an {{term(MTConnect + Agent)}}. + + + + + + + {{term(UUID)}} of the device whose {{term(metadata)}} has changed. + + + + + + + status of the connection between an {{term(adapter)}} and an + {{term(agent)}}. + + + + + + + originator’s software version of the {{term(adapter)}}. + + + + + + + {{term(URI)}} of the {{term(adapter)}}. + + + + + + + reference version of the MTConnect Standard supported by the + {{term(adapter)}}. + + + + + + + {{term(attachment)}} between a sensor and an entity. + + + + + + + state or condition of a part. + + + + + + + identifier of a process being executed by the device. + + + + + + + identifier given to link the individual occurrence to a group of + related occurrences, such as a process step in a process plan. + + + + + + + identifier given to link the individual occurrence to a class of + processes or process definition. + + + + + + + identifier given to a collection of individual parts. + + + + + + + identifier given to link the individual occurrence to a class of + parts, typically distinguished by a particular part design. + + + + + + + identifier given to a distinguishable, individual part. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. **DEPRECATION WARNING**. Recommend using + `CONTROL_LIMITS`. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. **DEPRECATION WARNING**. Recommend using + `SPECIFICATION_LIMITS`. + + + + + + + set of limits used to trigger warning or alarm indicators. + **DEPRECATION WARNING**. Recommend using `ALARM_LIMITS`. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, load materials, parts, or other items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, unload materials, parts, or other + items. + + + + + + + accumulation of the number of times an operation has attempted to, + or is planned to attempt to, transfer materials, parts, or other + items from one location to another. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, activate or be performed. + + + + + + + accumulation of the number of times a function has attempted to, or + is planned to attempt to, deactivate or cease. + + + + + + + accumulation of the number of times a cyclic function has attempted + to, or is planned to attempt to execute. + + + + + + + state of a valve is one of open, closed, or transitioning between + the states. + + + + + + + state or operating mode of a {{block(Lock)}}. + + + + + + + particular condition of the process occurrence at a specific time. + + + + + + + particular condition of the part occurrence at a specific time. + + + + + + + state of {{block(Component)}} or {{block(Composition)}} that + describes the automatic or manual operation of the entity. + + + + + + + {{term(data set)}} of the number of {{termplural(Asset)}} of a given + type for a {{term(Device)}}. + + + + + + + actions or activities to be performed in support of a piece of + equipment. + + + + + + + identifier for the current workholding or part clamp in use by a + piece of equipment. + + + + + + + interpretation of `PART_COUNT`. + + + + + + + time provided by a timing device at a specific point in time. + + + + + + + name of the host computer supplying data. + + + + + + + number of the TCP/IP or UDP/IP port for the connection endpoint. + + + + + + + indication designating whether a leak has been detected. + + + + + + + present status of the battery. + + + + + + + {{term(UUID)}} of a {{term(feature)}}. {{cite(ISO 10303 AP + 242/239)}}. + + + + + + + detection result of a sensor. + + + + + + + {{block(Event)}} that represents a {{block(Component)}} where the + {{block(EntryDefinition)}} identifies the {{block(Component)}} and + the {{block(CellDefinition)}}s define the + {{block(Component)}}'s observed {{block(DataItem)}}s. + + + + + + + properties of each addressable work offset. + + + + + + + properties of each addressable tool offset. + + + + + + + assessing elements of a {{term(feature)}}. + + + + + + + {{term(UUID)}} of the {{term(characteristic)}}. + + + + + + + class of measurement being performed. {{cite(QIF 3:2018 Section + 6.3)}} + + + + + + + measurement based on the measurement type. + + + + + + + engineering units of the measurement. + + + + + + + pass/fail result of the measurement. + + + + + + + method used to compute {{term(standard uncertainty)}}. + + + + + + + {{term(uncertainty)}} specified by {{block(UncertaintyType)}}. + + + + + + + set of limits defining a range of values designating acceptable + performance for a variable. + + + + + + + set of limits used to indicate whether a process variable is stable + and in control. + + + + + + + set of limits used to trigger warning or alarm indicators. + + + + + + + references the {{block(CuttingToolLifeCycle)}} + {{block(CuttingItem)}} index related to the + {{property(CuttingItem::indices)}} of the currently active cutting + tool edge. + + + + + + + structured information that allows the unambiguous determination of + an object for purposes of identification and location. {{cite(ISO + 19160-4:2017)}} + + + + + + + active energy source for the {{block(Component)}}. + + + + + + + textual description of the location of an object or activity. + + + + + + + dimension between two surfaces of an object, usually the dimension + of smallest measure, for example an additive layer, or a depth of + cut. + + + + + + + absolute geographic location defined by two coordinates, longitude + and latitude and an elevation. + + + + + + + indication that the piece of equipment has experienced a + communications failure. + + + + + + + indication that the value of the data associated with a measured + value or a calculation is outside of an expected range. + + + + + + + indication that an error occurred in the logic program or + programmable logic controller (PLC) associated with a piece of + equipment. + + + + + + + indication that an error occurred in the motion program associated + with a piece of equipment. + + + + + + + general purpose indication associated with an electronic component + of a piece of equipment or a controller that represents a fault that + is not associated with the operator, program, or hardware. + + + + + + + indication of a fault associated with an actuator. + + + + + + + operational state of an {{block(Interface)}}. + + + + + + + operating state of the service to advance material or feed product + to a piece of equipment from a continuous or bulk source. + + + + + + + operating state of the service to change the type of material or + product being loaded or fed to a piece of equipment. + + + + + + + operating state of the service to remove or retract material or + product. + + + + + + + operating state of the service to change the part or product + associated with a piece of equipment to a different part or product. + + + + + + + operating state of the service to load a piece of material or + product. + + + + + + + operating state of the service to unload a piece of material or + product. + + + + + + + operating state of the service to open a chuck. + + + + + + + operating state of the service to open a door. + + + + + + + operating state of the service to close a chuck. + + + + + + + operating state of the service to close a door. + + + + + + + A user variable + + + + + + + + + The types of measurements available + + + + + + + + Extended tyoe for The sub-types for a measurement + + + + + + + + + + The sub-types for a measurement + + + + + + + relating to or derived in the simplest manner from the fundamental + units or measurements. + + + + + + + indication of the operating state of a mechanism. + + + + + + + measured or reported value of an {{term(observation)}}. + + + + + + + all actions, items, or activities being counted independent of the + outcome. + + + + + + + measurement of alternating voltage or current. If not specified + further in statistic, defaults to RMS voltage. **DEPRECATED** in + *Version 1.6*. + + + + + + + A-Scale weighting factor on the frequency scale. + + + + + + + when multiple locations on a piece of bar stock being feed by a bar + feeder are referenced as the indication of whether the end of that + piece of bar stock has been reached. + + + + + + + actions, items, or activities being counted that do not conform to + specification or expectation. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + B-Scale weighting factor on the frequency scale. + + + + + + + directive value including adjustments such as an offset or + overrides. + + + + + + + amount of material consumed from an object or container during a + manufacturing process. + + + + + + + state of the enabling signal or control logic that enables or + disables the function or operation of the entity. + + + + + + + C-Scale weighting factor on the frequency scale. + + + + + + + elapsed time of a temporary halt of action. + + + + + + + DC current or voltage. **DEPRECATED** in *Version 1.6*. + + + + + + + setting or operator selection used to execute a test mode to confirm + the execution of machine functions. + + + + + + + D-Scale weighting factor on the frequency scale. + + + + + + + relating to the expiration or end of useful life for a material or + other physical item. + + + + + + + relating to the first use of a material or other physical item. + + + + + + + actions, items, or activities being counted that conform to + specification or expectation. + + + + + + + relating to or derived from the last {{term(observation)}}. + + + + + + + relating to momentary activation of a function or a movement. + **DEPRECATION WARNING**: May be deprecated in the future. + + + + + + + indication of the position of a mechanism that may move in a lateral + direction. + + + + + + + scale to measure the elasticity of a surface. + + + + + + + reference to a length type tool offset variable. + + + + + + + state of the power source. + + + + + + + direction of motion of a linear motion. + + + + + + + indication that the subparts of a piece of equipment are under load. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + relating to the primary logic or motion program currently being + executed. + + + + + + + relating to maintenance on the piece of equipment. + + + + + + + indication of the state of an operator controlled interlock that can + inhibit the ability to initiate an unclamp action of an + electronically controlled chuck. + + + + + + + related to the production of a material or other physical item. + + + + + + + maximum value. + + + + + + + minimum value. + + + + + + + scale to measure the resistance to scratching of a surface. + + + + + + + indication of the open or closed state of a mechanism. + + + + + + + no weighting factor on the frequency scale. + + + + + + + piece of equipment that is powered or performing any activity. + + + + + + + relating to the person currently responsible for operating the piece + of equipment. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + overridden value. + + + + + + + piece of equipment is powered and functioning or + {{block(Component)}} that are required to remain on are powered. + + + + + + + main or principle. + + + + + + + position provided by a measurement probe. **DEPRECATION WARNING**: + May be deprecated in the future. + + + + + + + relating to production of a part or product on a piece of equipment. + + + + + + + directive value without offsets and adjustments. + + + + + + + reference to a radial type tool offset variable. + + + + + + + performing an operation faster or in less time than nominal rate. + + + + + + + remaining measure or count of an action, object or activity. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + direction of a rotary motion using the right hand rule convention. + + + + + + + identity of a control program that is used to specify the order of + execution of other programs. + + + + + + + relating to the preparation of a piece of equipment for production + or restoring the piece of equipment to a neutral state after + production. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + standard measure of an object or an action. + + + + + + + boundary when an activity or an event commences. + + + + + + + indication of the activation state of a mechanism represented by a + {{block(Composition)}}. + + + + + + + goal of the operation or process. + + + + + + + relating to the end or completion of an activity or event. + + + + + + + setting or operator selection that changes the behavior of the + controller on a piece of equipment. + + + + + + + remaining usable measure of an object or action. + + + + + + + indication of the position of a mechanism that may move in a + vertical direction. + + + + + + + scale to measure the resistance to deformation of a surface. + + + + + + + piece of equipment performing any activity, the equipment is active + and performing a function under load or not. + + + + + + + IPV4 network address of the {{block(Component)}}. + + + + + + + IPV6 network address of the {{block(Component)}}. + + + + + + + Gateway for the {{block(Component)}} network. + + + + + + + SubNet mask for the {{block(Component)}} network. + + + + + + + layer2 Virtual Local Network (VLAN) ID for the {{block(Component)}} + network. + + + + + + + Media Access Control Address. The unique physical address of the + network hardware. + + + + + + + identifies whether the connection type is wireless. + + + + + + + license code to validate or activate the hardware or software. + + + + + + + version of the hardware or software. + + + + + + + date the hardware or software was released for general use. + + + + + + + date the hardware or software was installed. + + + + + + + corporate identity for the maker of the hardware or software. + + + + + + + universally unique identifier as specified in ISO 11578 or RFC 4122. + + + + + + + serial number that uniquely identifies a specific part. + + + + + + + material that is used to produce parts. + + + + + + + group of parts tracked as a lot. + + + + + + + group of parts produced in a batch. + + + + + + + material heat number. + + + + + + + particular part design or model. + + + + + + + group of parts having similarities in geometry, manufacturing + process, and/or functions. + + + + + + + word or set of words by which a part is known, addressed, or + referred to. + + + + + + + step in the process plan that this occurrence corresponds to. + + + + + + + process plan that a process occurrence belongs to. + + + + + + + authorization of a process occurrence. + + + + + + + word or set of words by which a process being executed (process + occurrence) by the device is known, addressed, or referred to. + + + + + + + reference to a ISO 10303 Executable. + + + + + + + associated with the completion of an activity or event. + + + + + + + relating to logic or motion program currently executing. + + + + + + + actions or activities that were attempted , but failed to complete + or resulted in an unexpected or unacceptable outcome. + + + + + + + actions or activities that were attempted, but terminated before + they could be completed. + + + + + + + boundary when an activity or an event terminates. + + + + + + + amount discarded. + + + + + + + amount included in the {{term(part)}}. + + + + + + + {{term(request)}} by an {{block(Interface)}} for a task. + + + + + + + {{term(response)}} by an {{block(Interface)}} to a {{term(request)}} + for a task. + + + + + + + phase or segment of a recipe or program. + + + + + + + phase of a recipe process. + + + + + + + process as part of product production; can be a subprocess of a + larger process. + + + + + + + step of a discrete manufacturing process. + + + + + + + observed as a binary data type. + + + + + + + observed as a boolean data type. + + + + + + + observed as a set containing a restricted number of discrete values + where each discrete value is named and unique. {{cite(ISO + 21961:2003, 013)}} + + + + + + + indicated by the presence or existence of something. + + + + + + + model info of the hardware or software. + + + + + + + + + The sub-types for a measurement + + + + + + + + Extended tyoe for Statistical operations on data + + + + + + + + + + Statistical operations on data + + + + + + + mathematical average value calculated for the data item during the + calculation period. + + + + + + + **DEPRECATED** in *Version 1.6*. ~~A measure of the + "peakedness" of a probability distribution; i.e., the + shape of the distribution curve.~~ + + + + + + + maximum or peak value recorded for the data item during the + calculation period. + + + + + + + middle number of a series of numbers. + + + + + + + minimum value recorded for the data item during the calculation + period. + + + + + + + number in a series of numbers that occurs most often. + + + + + + + difference between the maximum and minimum value of a data item + during the calculation period. Also represents Peak-to-Peak + measurement in a waveform. + + + + + + + mathematical Root Mean Square (RMS) value calculated for the data + item during the calculation period. + + + + + + + statistical Standard Deviation value calculated for the data item + during the calculation period. + + + + + + + + + Statistical operations on data + + + + + + + + Extended tyoe for same as {{property(DataItem::units)}}. See + {{package(Device Information Model)}}. + + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + + + same as {{property(DataItem::units)}}. See {{package(Device Information + Model)}}. + + + + + + + + Extended tyoe for The units supported for the source equipment that can + be converted into MTC Units. + + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + amps. + + + + + + + degrees Celsius. + + + + + + + count of something. + + + + + + + sound level. + + + + + + + angle in degrees. + + + + + + + space-delimited, floating-point representation of the angular + rotation in degrees around the X, Y, and Z axes relative to a + cartesian coordinate system respectively in order as A, B, and C. If + any of the rotations is not known, it **MUST** be zero (0). + + + + + + + angular degrees per second. + + + + + + + angular acceleration in degrees per second squared. + + + + + + + frequency measured in cycles per second. + + + + + + + measurement of energy. + + + + + + + kilograms. + + + + + + + measurement of volume of a fluid. + + + + + + + liters per second. + + + + + + + measurement of tilt. + + + + + + + millimeters. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in millimeters. + + + + + + + millimeters per revolution. + + + + + + + millimeters per second. + + + + + + + acceleration in millimeters per second squared. + + + + + + + force in Newtons. + + + + + + + torque, a unit for force times distance. + + + + + + + measure of electrical resistance. + + + + + + + pressure in Newtons per square meter. + + + + + + + measurement of viscosity. + + + + + + + percentage. + + + + + + + measure of the acidity or alkalinity of a solution. + + + + + + + revolutions per minute. + + + + + + + measurement of time. + + + + + + + measurement of electrical conductivity. + + + + + + + volts. + + + + + + + measurement of the apparent power in an electrical circuit, equal to + the product of root-mean-square (RMS) voltage and RMS current + (commonly referred to as VA). + + + + + + + measurement of reactive power in an AC electrical circuit (commonly + referred to as VAR). + + + + + + + watts. + + + + + + + measurement of electrical energy, equal to one Joule. + + + + + + + gram per cubic meter. + + + + + + + geometric volume in millimeters. + + + + + + + change of geometric volume per second. + + + + + + + change in geometric volume per second squared. + + + + + + + milligram. + + + + + + + milligram per cubic millimeter. + + + + + + + milliliter. + + + + + + + counts per second. + + + + + + + pascal per second. + + + + + + + 3D Unit Vector. Space delimited list of three floating point + numbers. + + + + + + + revolutions per second squared. + + + + + + + rotational velocity in revolution per second. + + + + + + + gram. + + + + + + + acceleration in meters per second squared. + + + + + + + electric charge in coulombs (C). + + + + + + + geometric volume in meters. + + + + + + + geometric area in millimeters. + + + + + + + measure of viscosity. + + + + + + + rotational velocity in degrees per minute. + + + + + + + temperature in Fahrenheit. + + + + + + + feet. + + + + + + + feet per minute. + + + + + + + feet per second. + + + + + + + acceleration in feet per second squared. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in feet. + + + + + + + gallons per minute. + + + + + + + measurement of time in hours. + + + + + + + inches. + + + + + + + inches per minute. + + + + + + + inches per second. + + + + + + + acceleration in inches per second squared. + + + + + + + measure of torque in inch pounds. + + + + + + + point in space identified by X, Y, and Z positions and represented + by a space-delimited set of numbers each expressed in inches. + + + + + + + measurement of temperature. + + + + + + + measurement in kilowatt. + + + + + + + kilowatt hours which is 3.6 mega joules. + + + + + + + measurement of rate of flow of a fluid. + + + + + + + velocity in millimeters per minute. + + + + + + + measurement of time in minutes. + + + + + + + unsupported unit. + + + + + + + US pounds. + + + + + + + pressure in pounds per square inch (PSI). + + + + + + + angle in radians. + + + + + + + velocity in radians per minute. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + rotational acceleration in radian per second squared. + + + + + + + pressure in Bar. + + + + + + + pressure in Torr. + + + + + + + pressure in Millimeter of Mercury (mmHg). + + + + + + + pascal per minute. + + + + + + + $$MASS\times GRAVITATIONAL_ACCELERATION$$ (g) given in + `METER/SECOND^2`. + + + + + + + acceleration relative to earth's gravity given in + `METER/SECOND^2`. > Note 1 to entry: At different points on + Earth's surface, the free-fall acceleration ranges from 9.764 + to 9.834 m/s2 (Wikipedia: Gravitational Acceleration). The constant + can be customized depending on the location in the universe. > + Note 2 to entry: In the standard, it is assumed that Earth's + average value of gravitational acceleration is 9.90665 m/s2. + + + + + + + electric charge in ampere hour. + + + + + + + change of geometric volume in cubic foot per hour. + + + + + + + change of geometric volume in cubic foot per minute. + + + + + + + geometric area in inches. + + + + + + + geometric volume in feet. + + + + + + + inch per revolution. + + + + + + + + + The units supported for the source equipment that can be converted into + MTC Units. + + + + + + + + The coordinate system to be used for the position + + + + + + + unchangeable coordinate system that has machine zero as its origin. + + + + + + + coordinate system that represents the working area for a particular + workpiece whose origin is shifted within the `MACHINE` coordinate + system. If the `WORK` coordinates are not currently defined in the + piece of equipment, the `MACHINE` coordinates will be used. + + + + + + + + + Extended tyoe for The reset intervals + + + + + + + + + + The reset intervals + + + + + + + {{term(observation)}} of the {{block(DataItem)}} that is measuring + an action or operation is to be reset upon completion of that action + or operation. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 12-month period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 24-hour period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is not reset and + accumulates for the entire life of the piece of equipment. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset upon + completion of a maintenance event. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a monthly period. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset when + power was applied to the piece of equipment after a planned or + unplanned interruption of power has occurred. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a work shift. + + + + + + + {{term(observation)}} of the {{block(DataItem)}} is to be reset at + the end of a 7-day period. + + + + + + + + + The reset intervals + + + + + + + + + The document version + + + + + + + time the file was created. + + + + + + + Indicates that this was a test document + + + + + + + The unique instance identifier of this agent process + + + + + + + The sender of the message + + + + + + + A timestamp in 8601 format of the last update of the Device + information for any device + + + + + + + + The station id for this device + + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the data + management within the {{term(agent)}}. + + + + + + + + + The size of the agent's buffer. + + + + + + + The next sequence number for subsequent requests + + + + + + + The last sequence number available from the agent + + + + + + + The first sequence number available from the agent + + + + + + + + + + root entity of an {{term(MTConnectStreams Response Document)}} that + contains the {{term(Observation Information Model)}} of one or more + {{block(Device)}} entities. + ![MTConnectStreams](figures/MTConnectStreams.png + "MTConnectStreams"){: width="0.8"} > Note: + Additional properties of {{block(MTConnectStreams)}} **MAY** be defined + for schema and namespace declaration. See {{sect(Schema and Namespace + Declaration Information)}} for an {{term(XML)}} example. + + + + + + + provides information from an {{term(agent)}} defining version + information, storage capacity, and parameters associated with the + data management within the {{term(agent)}}. + + + + + + + {{block(Streams)}} groups one or more {{block(DeviceStream)}} + entities. See {{package(Observation Information Model)}} for more + detail. + + + + + + + + + An events data + + + + + + + + The item's unique ID that references the data item id from probe + + + + + + + + An Condition code as defined by the component + + + + + + + + {{block(Streams)}} groups one or more {{block(DeviceStream)}} entities. + See {{package(Observation Information Model)}} for more detail. + + + + + + + Description + + + + + + + + + Description + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} + for the {{block(ComponentStream)}} model. > Note 1 to entry: In + the {{term(XML)}} representation, {{block(ComponentStream)}} + entities **MUST NOT** appear in the {{term(MTConnectDevices Response + Document)}}. > Note 2 to entry: In the {{term(XML)}} + representation, {{block(ComponentStream)}} entities **MUST** appear + only in the {{term(MTConnectStreams Response Document)}}. + + + + + + + + identifier of the maintenance activity. + + + + + + + The unque identifier for this device + + + + + + + + {{block(ComponentStream)}} {{termplural(organize)}} the + {{block(Observation)}} entities associated with the + {{block(Component)}}. See {{package(Observation Information Model)}} for + the {{block(ComponentStream)}} model. > Note 1 to entry: In the + {{term(XML)}} representation, {{block(ComponentStream)}} entities **MUST + NOT** appear in the {{term(MTConnectDevices Response Document)}}. > + Note 2 to entry: In the {{term(XML)}} representation, + {{block(ComponentStream)}} entities **MUST** appear only in the + {{term(MTConnectStreams Response Document)}}. + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. + See {{sect(Sample)}}. + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + Description + + + + + + + + The id of the component (maps to the id from probe) + + + + + + + identifier of the maintenance activity. + + + + + + + The device manufacturer component name + + + + + + + Description + + + + + + + The unque identifier for this component + + + + + + + + {{block(Samples)}} groups one or more {{block(Sample)}} entities. See + {{sect(Sample)}}. + + + + + + + + + + {{block(Events)}} groups one or more {{block(Event)}} entities. See + {{sect(Event)}}. + + + + + + + + + + A collection of conditions + + + + + + + + + + The observation value for indeterminent data + + + + + + + Data is unavailable + + + + + + + + + + The events sequence number + + + + + + + The event subtype corresponding to the measurement subtype + + + + + + + The time the event occurred or recorded + + + + + + + identifier of the maintenance activity. + + + + + + + The unique identifier of the item being produced + + + + + + + The identifier of the sub-element this result is in reference to + + + + + + + + The target rate a value can be sampled + + + + + + + + The number of items in the list + + + + + + + + Common floating point sample value + + + + + + + + Common floating point sample value + + + + + + + + Description + + + + + + + The rate the waveform was sampled at, default back to the value given + in the data item + + + + + + + An optional indicator that the event or sample was reset + + + + + + + The statistical operation on this data + + + + + + + The number of seconds since the reset of the statistic + + + + + + + + Description + + + + + + + A sample with a single floating point value + + + + + + + + + + + + + + A sample with a single floating point value + + + + + + + A sample with a three tuple floating point value + + + + + + + + + + + + + + A sample with a three tuple floating point value + + + + + + + The abstract waveform + + + + + + + + The number of samples + + + + + + + + + + The abstract waveform + + + + + + + Description + + + + + + + + + + + + + + Description + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCELERATION)}} + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + Time series of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE)}} + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + + + + {{def(SampleEnum::ANGLE)}} + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGLE)}} + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + + + + {{def(SampleEnum::FLOW)}} + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + + + + Time series of {{def(SampleEnum::FLOW)}} + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + {{def(SampleEnum::FREQUENCY)}} + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + Time series of {{def(SampleEnum::FREQUENCY)}} + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + + + + {{def(SampleEnum::LENGTH)}} + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + Time series of {{def(SampleEnum::LENGTH)}} + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + + + + {{def(SampleEnum::LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::LEVEL)}} + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + + + + {{def(SampleEnum::LOAD)}} + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + + + + Time series of {{def(SampleEnum::LOAD)}} + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + + + + {{def(SampleEnum::MASS)}} + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + + + + Time series of {{def(SampleEnum::MASS)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + Time series of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Example + + + + + + + + + + Example + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + + + + {{def(SampleEnum::PH)}} + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + + + + Time series of {{def(SampleEnum::PH)}} + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + + + + {{def(SampleEnum::POSITION)}} + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + + + + Time series of {{def(SampleEnum::POSITION)}} + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + Time series of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Description + + + + + + + + + + Description + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURE)}} + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + Time series of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + {{def(SampleEnum::RESISTANCE)}} + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + Time series of {{def(SampleEnum::RESISTANCE)}} + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + Time series of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + Time series of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + + + + {{def(SampleEnum::STRAIN)}} + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + Time series of {{def(SampleEnum::STRAIN)}} + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + + + + {{def(SampleEnum::TENSION)}} + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::TENSION)}} + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + + + + {{def(SampleEnum::TILT)}} + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + + + + Time series of {{def(SampleEnum::TILT)}} + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + + + + {{def(SampleEnum::TORQUE)}} + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + Time series of {{def(SampleEnum::TORQUE)}} + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + {{def(SampleEnum::VELOCITY)}} + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VELOCITY)}} + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + {{def(SampleEnum::VISCOSITY)}} + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::VISCOSITY)}} + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + {{def(SampleEnum::WATTAGE)}} + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::WATTAGE)}} + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + Time series of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + Time series of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + {{def(SampleEnum::DIAMETER)}} + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + Time series of {{def(SampleEnum::DIAMETER)}} + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + {{def(SampleEnum::ORIENTATION)}} + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + Time series of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::DECELERATION)}} + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + + + + The force per unit area measured relative to a vacuum. + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + + + + Time series of The force per unit area measured relative to a vacuum. + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + {{def(SampleEnum::OPENNESS)}} + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + Time series of {{def(SampleEnum::OPENNESS)}} + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + {{def(SampleEnum::DEW_POINT)}} + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + Time series of {{def(SampleEnum::DEW_POINT)}} + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + Time series of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + Time series of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + Time series of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + Time series of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The displacement + vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + Time series of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + Integer event value + + + + + + + + Integer event value + + + + + + + + String event value + + + + + + + + DateTime String event value + + + + + + + + A list of axis names + + + + + + + + + + + + A list of axis for an event + + + + + + + + Common floating point event value + + + + + + + + Description + + + + + + + An optional indicator that the event or sample was reset + + + + + + + + Description + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted string event + + + + + + + + + + + + + + An unfaceted string event + + + + + + + An unfaceted datetime event + + + + + + + + + + + + + + An unfaceted datetime event + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with an integer value + + + + + + + + + + + + + + An event with an integer value + + + + + + + An event with a three tuple floating point value + + + + + + + + + + + + + + An event with a three tuple floating point value + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Controlled vocabulary for ActuatorState + + + + + + + {{block(Actuator)}} is operating. + + + + + + + {{block(Actuator)}} is not operating. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + The type of asset + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Controlled vocabulary for Availability + + + + + + + data source is active and capable of providing data. + + + + + + + data source is either inactive or not capable of providing data. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + {{def(EventEnum::AVAILABILITY)}} + + + + + + + Controlled vocabulary for AxisCoupling + + + + + + + axes are physically connected to each other and operate as a single + unit. + + + + + + + axes are not physically connected to each other but are operating + together in lockstep. + + + + + + + axis is the master of the {{block(CoupledAxes)}}. + + + + + + + axis is a slave to the {{block(CoupledAxes)}}. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for AxisInterlock + + + + + + + axis lockout function is activated, power has been removed from the + axis, and the axis is allowed to move freely. + + + + + + + axis lockout function has not been activated, the axis may be + powered, and the axis is capable of being controlled by another + component. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Controlled vocabulary for AxisState + + + + + + + axis is in its home position. + + + + + + + axis is in motion. + + + + + + + axis has been moved to a fixed position and is being maintained in + that position either electrically or mechanically. Action is + required to release the axis from this position. + + + + + + + axis is stopped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::AXIS_STATE)}} + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + + + + {{def(EventEnum::BLOCK)}} + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Controlled vocabulary for ChuckInterlock + + + + + + + chuck cannot be unclamped. + + + + + + + chuck can be unclamped. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Controlled vocabulary for ChuckState + + + + + + + {{block(Chuck)}} is open to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Chuck)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::CHUCK_STATE)}} + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Controlled vocabulary for ControllerMode + + + + + + + {{block(Controller)}} is configured to automatically execute a + program. + + + + + + + {{block(Controller)}} is not executing an active program. It is + capable of receiving instructions from an external source – + typically an operator. The {{block(Controller)}} executes operations + based on the instructions received from the external source. + + + + + + + operator can enter a series of operations for the + {{block(Controller)}} to perform. The {{block(Controller)}} will + execute this specific series of operations and then stop. + + + + + + + {{block(Controller)}} is operating in a mode that restricts the + active program from processing its next process step without + operator intervention. + + + + + + + {{block(Controller)}} is currently functioning as a programming + device and is not capable of executing an active program. + + + + + + + axes of the device are commanded to stop, but the spindle continues + to function. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Controlled vocabulary for ControllerModeOverride + + + + + + + {{block(ControllerModeOverride)}} is in the `ON` state and the mode + override is active. + + + + + + + {{block(ControllerModeOverride)}} is in the `OFF` state and the mode + override is inactive. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + {{def(EventEnum::COUPLED_AXES)}} + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + {{def(EventEnum::DATE_CODE)}} + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Controlled vocabulary for Direction + + + + + + + clockwise rotation using the right-hand rule. + + + + + + + counter-clockwise rotation using the right-hand rule. + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + {{def(EventEnum::DIRECTION)}} + + + + + + + Controlled vocabulary for DoorState + + + + + + + {{block(Door)}} is open to the point of a positive confirmation. + + + + + + + {{block(Door)}} is closed to the point of a positive confirmation. + + + + + + + {{block(Door)}} is not closed to the point of a positive + confirmation and not open to the point of a positive confirmation. + It is in an intermediate position. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::DOOR_STATE)}} + + + + + + + Controlled vocabulary for EmergencyStop + + + + + + + emergency stop circuit is complete and the piece of equipment, + component, or composition is allowed to operate. + + + + + + + operation of the piece of equipment, component, or composition is + inhibited. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Controlled vocabulary for EndOfBar + + + + + + + {{block(EndOfBar)}} has been reached. + + + + + + + {{block(EndOfBar)}} has not been reached. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + {{def(EventEnum::END_OF_BAR)}} + + + + + + + Controlled vocabulary for EquipmentMode + + + + + + + equipment is functioning in the mode designated by the `subType`. + + + + + + + equipment is not functioning in the mode designated by the + `subType`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Controlled vocabulary for Execution + + + + + + + {{block(Component)}} is ready to execute instructions. It is + currently idle. + + + + + + + {{block(Component)}} is actively executing an instruction. + + + + + + + {{block(Component)}} suspends the execution of the program due to an + external signal. Action is required to resume execution. + + + + + + + motion of the active axes are commanded to stop at their current + position. + + + + + + + {{block(Component)}} program is not `READY` to execute. + + + + + + + command from the program has intentionally interrupted execution. + The {{block(Component)}} **MAY** have another state that indicates + if the execution is interrupted or the execution ignores the + interrupt instruction. + + + + + + + command from the program has intentionally interrupted execution. + Action is required to resume execution. + + + + + + + program completed execution. + + + + + + + {{block(Component)}} suspends execution while a secondary operation + executes. Execution resumes automatically once the secondary + operation completes. + + + + + + + program has been intentionally optionally stopped using an M01 or + similar code. **DEPRECATED** in *version 1.4* and replaced with + `OPTIONAL_STOP`. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + {{def(EventEnum::EXECUTION)}} + + + + + + + Controlled vocabulary for FunctionalMode + + + + + + + {{block(Component)}} is currently producing product, ready to + produce product, or its current intended use is to be producing + product. + + + + + + + {{block(Component)}} is not currently producing product. It is being + prepared or modified to begin production of product. + + + + + + + {{block(Component)}} is not currently producing product. Typically, + it has completed the production of a product and is being modified + or returned to a neutral state such that it may then be prepared to + begin production of a different product. + + + + + + + {{block(Component)}} is not currently producing product. It is + currently being repaired, waiting to be repaired, or has not yet + been returned to a normal production status after maintenance has + been performed. + + + + + + + {{block(Component)}} is being used to prove-out a new process, + testing of equipment or processes, or any other active use that does + not result in the production of product. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + + + + {{def(EventEnum::HARDNESS)}} + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + + + + {{def(EventEnum::LINE)}} + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + {{def(EventEnum::LINE_LABEL)}} + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + {{def(EventEnum::LINE_NUMBER)}} + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + + + + {{block(Resource)}} composed of material that is consumed or used by the + piece of equipment for production of parts, materials, or other types of + goods. + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + + + + {{def(EventEnum::MESSAGE)}} + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + {{def(EventEnum::OPERATOR_ID)}} + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + {{def(EventEnum::PALLET_ID)}} + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + {{def(EventEnum::PART_COUNT)}} + + + + + + + Controlled vocabulary for PartDetect + + + + + + + part or work piece is detected or is present. + + + + + + + part or work piece is not detected or is not present. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_DETECT)}} + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + + + + {{def(EventEnum::PART_ID)}} + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + {{def(EventEnum::PART_NUMBER)}} + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Controlled vocabulary for PathMode + + + + + + + path is operating independently and without the influence of another + path. + + + + + + + path provides information or state values that influences the + operation of other {{block(DataItem)}} of similar type. + + + + + + + physical or logical parts which are not physically connected to each + other but are operating together. + + + + + + + axes associated with the path are mirroring the motion of the + `MASTER` path. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::PATH_MODE)}} + + + + + + + Controlled vocabulary for PowerState + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is present and + active. + + + + + + + source of energy for an entity or the enabling signal providing + permission for the entity to perform its function(s) is not present + or is disconnected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATE)}} + + + + + + + Controlled vocabulary for PowerStatus + + + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::POWER_STATUS)}} + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + {{def(EventEnum::PROCESS_TIME)}} + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + + + + {{def(EventEnum::PROGRAM)}} + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Controlled vocabulary for ProgramEdit + + + + + + + {{block(Controller)}} is in the program edit mode. + + + + + + + {{block(Controller)}} is capable of entering the program edit mode + and no function is inhibiting a change to that mode. + + + + + + + {{block(Controller)}} is being inhibited by a function from entering + the program edit mode. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Controlled vocabulary for ProgramLocationType + + + + + + + managed by the controller. + + + + + + + not managed by the controller. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is not + defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Controlled vocabulary for RotaryMode + + + + + + + axis is functioning as a spindle. + + + + + + + axis is configured to index. + + + + + + + position of the axis is being interpolated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::ROTARY_MODE)}} + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command represents a + percentage change to the velocity calculated by a logic or motion + program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Controlled vocabulary for SpindleInterlock + + + + + + + power has been removed and the spindle cannot be operated. + + + + + + + spindle has not been deactivated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + {{def(EventEnum::TOOL_GROUP)}} + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + {{def(EventEnum::TOOL_ID)}} + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + {{def(EventEnum::USER)}} + + + + + + + + + + {{def(EventEnum::USER)}} + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + + + + {{def(EventEnum::VARIABLE)}} + + + + + + + Controlled vocabulary for WaitState + + + + + + + execution is waiting while the equipment is powering up and is not + currently available to begin producing parts or products. + + + + + + + execution is waiting while the equipment is powering down but has + not fully reached a stopped state. + + + + + + + execution is waiting while one or more discrete workpieces are being + loaded. + + + + + + + execution is waiting while one or more discrete workpieces are being + unloaded. + + + + + + + execution is waiting while a tool or tooling is being loaded. + + + + + + + execution is waiting while a tool or tooling is being unloaded. + + + + + + + execution is waiting while material is being loaded. + + + + + + + execution is waiting while material is being unloaded. + + + + + + + execution is waiting while another process is completed before the + execution can resume. + + + + + + + execution is waiting while the equipment is pausing but the piece of + equipment has not yet reached a fully paused state. + + + + + + + execution is waiting while the equipment is resuming the production + cycle but has not yet resumed execution. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + + + + + + + + {{def(EventEnum::WAIT_STATE)}} When {{property(Execution::result)}} is + not `WAIT`, {{property(Observation::isUnavailable)}} of + {{block(WaitState)}} **MUST** be `true`. + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + + + + leaf {{block(Component)}} composed of a string like piece or filament of + relatively rigid or flexible material provided in a variety of + diameters. + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + {{def(EventEnum::WORK_OFFSET)}} + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + {{def(EventEnum::FIRMWARE)}} + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + + + + {{def(EventEnum::APPLICATION)}} + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + + + + {{def(EventEnum::LIBRARY)}} + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + + + + {{def(EventEnum::HARDWARE)}} + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + + + + {{def(EventEnum::NETWORK)}} + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + + translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Controlled vocabulary for PartStatus + + + + + + + part conforms to given requirements. + + + + + + + part does not conform to some given requirements. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + + + + + + + + {{def(EventEnum::PART_STATUS)}} If unique identifier is given, part + status is for that individual. If group identifier is given without a + unique identifier, then the status is assumed to be for the whole group. + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_KIND_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_URI)}} + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Controlled vocabulary for ConnectionStatus + + + + + + + no connection at all. + + + + + + + {{term(agent)}} is waiting for a connection request from an + {{term(adapter)}}. + + + + + + + open connection. The normal state for the data transfer phase of the + connection. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + condensed message digest from a secure one-way hash function. + + + + + + + + + + {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_GROUP_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + + + + {{def(EventEnum::PART_UNIQUE_ID)}} If no {{property(DataItem::subType)}} + is specified, `UUID` is default. + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Controlled vocabulary for PartProcessingState + + + + + + + part occurrence is not actively being processed, but the processing + has not ended. Processing requirements exist that have not yet been + fulfilled. This is the default entry state when the part occurrence + is originally received. In some cases, the part occurrence may + return to this state while it waits for additional processing to be + performed. + + + + + + + part occurrence is actively being processed. + + + + + + + part occurrence is no longer being processed. A general state when + the reason for termination is unknown. + + + + + + + part occurrence has completed processing successfully. + + + + + + + process has been stopped during the processing. The part occurrence + will require special treatment. + + + + + + + processing of the part occurrence has come to a premature end. + + + + + + + terminal state when the part occurrence has been removed from the + equipment by an external entity and it no longer exists at the + equipment. + + + + + + + part occurrence has been skipped for processing on the piece of + equipment. + + + + + + + part occurrence has been processed completely. However, the + processing may have a problem. + + + + + + + part occurrence is waiting for transit. + + + + + + + part occurrence is being transported to its destination. + + + + + + + part occurrence has been placed at its designated destination. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Controlled vocabulary for ProcessState + + + + + + + device is preparing to execute the process occurrence. + + + + + + + process occurrence is ready to be executed. + + + + + + + process occurrence is actively executing. + + + + + + + process occurrence is now finished. + + + + + + + process occurrence has been stopped and may be resumed. + + + + + + + process occurrence has come to a premature end and cannot be + resumed. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Controlled vocabulary for ValveState + + + + + + + {{block(ValveState)}} where flow is allowed and the aperture is + static. > Note: For a binary value, `OPEN` indicates the valve + has the maximum possible aperture. + + + + + + + valve is transitioning from a `CLOSED` state to an `OPEN` state. + + + + + + + {{block(ValveState)}} where flow is not possible, the aperture is + static, and the valve is completely shut. + + + + + + + valve is transitioning from an `OPEN` state to a `CLOSED` state. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::VALVE_STATE)}} + + + + + + + Controlled vocabulary for LockState + + + + + + + mechanism is engaged and preventing the associated + {{block(Component)}} from being opened or operated. + + + + + + + mechanism is disengaged and the associated {{block(Component)}} is + able to be opened or operated. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::LOCK_STATE)}} + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Controlled vocabulary for OperatingMode + + + + + + + automatically execute instructions from a recipe or program. > + Note: Setpoint comes from a recipe. + + + + + + + execute instructions from an external agent or person. > Note 1 + to entry: Valve or switch is manipulated by an agent/person. > + Note 2 to entry: Direct control of the PID output. % of the range: A + user manually sets the % output, not the setpoint. + + + + + + + executes a single instruction from a recipe or program. > Note 1 + to entry: Setpoint is entered and fixed, but the PID is controlling. + > Note 2 to entry: Still goes through the PID control system. + > Note 3 to entry: Manual fixed entry from a recipe. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + {{def(EventEnum::OPERATING_MODE)}} + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + {{def(EventEnum::ASSET_COUNT)}} + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Controlled vocabulary for PartCountType + + + + + + + count is of individual items. + + + + + + + pre-specified group of items. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + {{def(EventEnum::CLOCK_TIME)}} + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + {{def(EventEnum::NETWORK_PORT)}} + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + {{def(EventEnum::HOST_NAME)}} + + + + + + + Controlled vocabulary for LeakDetect + + + + + + + leak is currently being detected. + + + + + + + leak is currently not being detected. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Controlled vocabulary for BatteryState + + + + + + + {{block(Component)}} is at it's maximum rated charge level. + + + + + + + {{block(Component)}}'s charge is increasing. + + + + + + + {{block(Component)}}'s charge is decreasing. + + + + + + + {{block(Component)}} is at it's minimum charge level. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + {{def(EventEnum::BATTERY_STATE)}} + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + {{def(EventEnum::SENSOR_STATE)}} + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + + + + tabular {{def(EventEnum::COMPONENT_DATA)}} If the {{block(Component)}} + multiplicity can be determined, the device model **MUST** use a fixed + set of {{block(Component)}}s. {{block(ComponentData)}} **MUST** provide + a {{block(DataItem)}} {{block(Definition)}}. + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + tabular representation of {{def(EventEnum::FEATURE_MEASUREMENT)}} + {{block(FeatureMeasurement)}} **MAY** include a {{term(characteristic)}} + in which case it **MAY** include a `CHARACTERISTIC_STATUS`. + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + + + + {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, `RADIUS`, + `ANGLE`, `LENGTH`, etc. + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Controlled vocabulary for CharacteristicStatus + + + + + + + measurement is within acceptable tolerances. + + + + + + + measurement is not within acceptable tolerances. + + + + + + + failed, but acceptable constraints achievable by utilizing + additional manufacturing processes. + + + + + + + measurement is indeterminate due to an equipment failure. + + + + + + + measurement cannot be determined. + + + + + + + measurement cannot be evaluated. + + + + + + + nominal provided without tolerance limits. {{cite(QIF 3:2018 + 5.10.2.6)}} + + + + + + + status of measurement cannot be determined. + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Controlled vocabulary for UncertaintyType + + + + + + + {{term(combined standard uncertainty)}}. + + + + + + + {{term(standard uncertainty)}} using arithmetic mean or average the + observations. {{cite(JCGM 100:2008 4.2)}} + + + + + + + Value is indeterminate + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + {{def(EventEnum::UNCERTAINTY)}} + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + + + + See {{sect(AlarmLimits)}}. + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + + + + See {{sect(ControlLimits)}}. + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + + + + See {{sect(SpecificationLimits)}}. + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + + + + {{def(EventEnum::THICKNESS)}} + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Controlled vocabulary for InterfaceState + + + + + + + {{block(Interface)}} is currently operational and performing as + expected. + + + + + + + {{block(Interface)}} is currently not operational. + + + + + + + Value is indeterminate + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + Discrete of {{def(EventEnum::PART_COUNT)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ID)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + Discrete of {{def(EventEnum::PALLET_ID)}} + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + Discrete of {{def(EventEnum::MESSAGE)}} + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + + + + Discrete of {{def(EventEnum::BLOCK)}} + + + + + + + Constraints for Entry Values + + + + + + the key + + + + + + + an indicatore that the entry has been removed + + + + + + + + Constraints for Entry Values + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AVAILABILITY)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::AXIS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CODE)}} + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DATE_CODE)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DIRECTION)}} + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DOOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::END_OF_BAR)}} + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::EXECUTION)}} + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::HARDNESS)}} + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LINE)}} + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LINE_LABEL)}} + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MESSAGE)}} + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PALLET_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PATH_MODE)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATE)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::POWER_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_ID)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::USER)}} + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::VARIABLE)}} + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FIRMWARE)}} + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::APPLICATION)}} + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LIBRARY)}} + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::HARDWARE)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK)}} + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of translations along X, Y, and Z axes are expressed as x,y, and + z respectively within a 3-dimensional vector. + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::VALVE_STATE)}} + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCK_STATE)}} + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::HOST_NAME)}} + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of See {{sect(AlarmLimits)}}. + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of See {{sect(ControlLimits)}}. + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of See {{sect(SpecificationLimits)}}. + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::THICKNESS)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGLE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FLOW)}} + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FREQUENCY)}} + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LENGTH)}} + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::LOAD)}} + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::MASS)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + DataSet of Example + + + + + + + + + + + + + + DataSet of Example + + + + + + + DataSet of Example + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of Example + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PH)}} + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION)}} + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + DataSet of Description + + + + + + + + + + + + + + DataSet of Description + + + + + + + DataSet of Description + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of Description + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::RESISTANCE)}} + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::STRAIN)}} + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TENSION)}} + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TILT)}} + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::TORQUE)}} + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VELOCITY)}} + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VISCOSITY)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::WATTAGE)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DIAMETER)}} + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ORIENTATION)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of The force per unit area measured relative to a vacuum. + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::OPENNESS)}} + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DEW_POINT)}} + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + DataSet of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + A cell of a table + + + + + + the key + + + + + + + + A cell of a table + + + + + + + {{term(key-value pair)}} published as part of a {{block(Table)}}. > + Note: In the {{term(XML)}} representation, {{block(TableEntry)}} + **MUST** appear as {{block(Entry)}}. + + + + + + + + + + + + + + {{term(key-value pair)}} published as part of a {{block(Table)}}. > + Note: In the {{term(XML)}} representation, {{block(TableEntry)}} + **MUST** appear as {{block(Entry)}}. + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Cell of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Table of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTIVE_AXES)}} + + + + + + + Table Entry of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + Cell of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + Table of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTUATOR_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + Cell of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + Table of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ASSET_CHANGED)}} + + + + + + + Table Entry of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Cell of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Table of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ASSET_REMOVED)}} + + + + + + + Table Entry of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AVAILABILITY)}} + + + + + + + Cell of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AVAILABILITY)}} + + + + + + + Table of {{def(EventEnum::AVAILABILITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AVAILABILITY)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + Cell of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + Table of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_COUPLING)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Cell of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Table of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_FEEDRATE_OVERRIDE)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Cell of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Table of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_INTERLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::AXIS_STATE)}} + + + + + + + Cell of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::AXIS_STATE)}} + + + + + + + Table of {{def(EventEnum::AXIS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::AXIS_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::BLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::BLOCK)}} + + + + + + + Cell of {{def(EventEnum::BLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::BLOCK)}} + + + + + + + Table of {{def(EventEnum::BLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::BLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Cell of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Table of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::BLOCK_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Cell of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Table of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHUCK_INTERLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + Cell of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + Table of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHUCK_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::CODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CODE)}} + + + + + + + Cell of {{def(EventEnum::CODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CODE)}} + + + + + + + Table of {{def(EventEnum::CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CODE)}} + + + + + + + Table Entry of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Cell of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Table of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::COMPOSITION_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONTROLLER_MODE_OVERRIDE)}} + + + + + + + Table Entry of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + Cell of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + Table of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::COUPLED_AXES)}} + + + + + + + Table Entry of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DATE_CODE)}} + + + + + + + Cell of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DATE_CODE)}} + + + + + + + Table of {{def(EventEnum::DATE_CODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DATE_CODE)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Table of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_UUID)}} + + + + + + + Table Entry of {{def(EventEnum::DIRECTION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DIRECTION)}} + + + + + + + Cell of {{def(EventEnum::DIRECTION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DIRECTION)}} + + + + + + + Table of {{def(EventEnum::DIRECTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DIRECTION)}} + + + + + + + Table Entry of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DOOR_STATE)}} + + + + + + + Cell of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DOOR_STATE)}} + + + + + + + Table of {{def(EventEnum::DOOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DOOR_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Cell of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Table of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::EMERGENCY_STOP)}} + + + + + + + Table Entry of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::END_OF_BAR)}} + + + + + + + Cell of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::END_OF_BAR)}} + + + + + + + Table of {{def(EventEnum::END_OF_BAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::END_OF_BAR)}} + + + + + + + Table Entry of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Cell of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Table of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::EQUIPMENT_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::EXECUTION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::EXECUTION)}} + + + + + + + Cell of {{def(EventEnum::EXECUTION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::EXECUTION)}} + + + + + + + Table of {{def(EventEnum::EXECUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::EXECUTION)}} + + + + + + + Table Entry of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + Cell of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + Table of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FUNCTIONAL_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::HARDNESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::HARDNESS)}} + + + + + + + Cell of {{def(EventEnum::HARDNESS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::HARDNESS)}} + + + + + + + Table of {{def(EventEnum::HARDNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::HARDNESS)}} + + + + + + + Table Entry of {{def(EventEnum::LINE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LINE)}} + + + + + + + Cell of {{def(EventEnum::LINE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LINE)}} + + + + + + + Table of {{def(EventEnum::LINE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LINE)}} + + + + + + + Table Entry of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LINE_LABEL)}} + + + + + + + Cell of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LINE_LABEL)}} + + + + + + + Table of {{def(EventEnum::LINE_LABEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LINE_LABEL)}} + + + + + + + Table Entry of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + Table of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LINE_NUMBER)}} + + + + + + + Table Entry of {{block(Resource)}} composed of material that is consumed + or used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{block(Resource)}} composed of material that is consumed + or used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + Cell of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + + + + + + Cell of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + Table of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{block(Resource)}} composed of material that is consumed or + used by the piece of equipment for production of parts, materials, or + other types of goods. + + + + + + + Table Entry of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + Cell of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + Table of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MATERIAL_LAYER)}} + + + + + + + Table Entry of {{def(EventEnum::MESSAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MESSAGE)}} + + + + + + + Cell of {{def(EventEnum::MESSAGE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MESSAGE)}} + + + + + + + Table of {{def(EventEnum::MESSAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MESSAGE)}} + + + + + + + Table Entry of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + Cell of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + Table of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::OPERATOR_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PALLET_ID)}} + + + + + + + Cell of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PALLET_ID)}} + + + + + + + Table of {{def(EventEnum::PALLET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PALLET_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT)}} + + + + + + + Cell of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_COUNT)}} + + + + + + + Table of {{def(EventEnum::PART_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_DETECT)}} + + + + + + + Cell of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_DETECT)}} + + + + + + + Table of {{def(EventEnum::PART_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_DETECT)}} + + + + + + + Table Entry of {{def(EventEnum::PART_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_ID)}} + + + + + + + Cell of {{def(EventEnum::PART_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_ID)}} + + + + + + + Table of {{def(EventEnum::PART_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_NUMBER)}} + + + + + + + Table of {{def(EventEnum::PART_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_NUMBER)}} + + + + + + + Table Entry of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Cell of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Table of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PATH_FEEDRATE_OVERRIDE)}} + + + + + + + Table Entry of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PATH_MODE)}} + + + + + + + Cell of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PATH_MODE)}} + + + + + + + Table of {{def(EventEnum::PATH_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PATH_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::POWER_STATE)}} + + + + + + + Cell of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::POWER_STATE)}} + + + + + + + Table of {{def(EventEnum::POWER_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::POWER_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::POWER_STATUS)}} + + + + + + + Cell of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::POWER_STATUS)}} + + + + + + + Table of {{def(EventEnum::POWER_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::POWER_STATUS)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + Table of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_TIME)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM)}} + + + + + + + Table of {{def(EventEnum::PROGRAM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_COMMENT)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_EDIT_NAME)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_HEADER)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_LOCATION_TYPE)}} + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial + value is not defined, the nesting level associated with the highest or + initial nesting level of the program **MUST** default to zero (0). + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial + value is not defined, the nesting level associated with the highest or + initial nesting level of the program **MUST** default to zero (0). + + + + + + + Cell of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Table of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROGRAM_NEST_LEVEL)}} If an initial value is + not defined, the nesting level associated with the highest or initial + nesting level of the program **MUST** default to zero (0). + + + + + + + Table Entry of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + Cell of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + Table of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ROTARY_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + Cell of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + + + + + + Cell of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + Table of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ROTARY_VELOCITY_OVERRIDE)}} This command + represents a percentage change to the velocity calculated by a logic or + motion program or set by a switch for a {{block(Rotary)}} type axis. + + + + + + + Table Entry of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Table of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SERIAL_NUMBER)}} + + + + + + + Table Entry of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + Cell of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + Table of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SPINDLE_INTERLOCK)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Cell of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Table of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_ASSET_ID)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + Cell of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + Table of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_GROUP)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_ID)}} + + + + + + + Cell of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_ID)}} + + + + + + + Table of {{def(EventEnum::TOOL_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_ID)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Cell of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Table of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_NUMBER)}} + + + + + + + Table Entry of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + Cell of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + Table of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_OFFSET)}} + + + + + + + Table Entry of {{def(EventEnum::USER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::USER)}} + + + + + + + Cell of {{def(EventEnum::USER)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::USER)}} + + + + + + + Table of {{def(EventEnum::USER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::USER)}} + + + + + + + Table Entry of {{def(EventEnum::VARIABLE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::VARIABLE)}} + + + + + + + Cell of {{def(EventEnum::VARIABLE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::VARIABLE)}} + + + + + + + Table of {{def(EventEnum::VARIABLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::VARIABLE)}} + + + + + + + Table Entry of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + Cell of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + + + + + + Cell of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + Table of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::WAIT_STATE)}} When + {{property(Execution::result)}} is not `WAIT`, + {{property(Observation::isUnavailable)}} of {{block(WaitState)}} + **MUST** be `true`. + + + + + + + Table Entry of leaf {{block(Component)}} composed of a string like piece + or filament of relatively rigid or flexible material provided in a + variety of diameters. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of leaf {{block(Component)}} composed of a string like piece + or filament of relatively rigid or flexible material provided in a + variety of diameters. + + + + + + + Cell of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + + + + + + Cell of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + Table of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of leaf {{block(Component)}} composed of a string like piece or + filament of relatively rigid or flexible material provided in a variety + of diameters. + + + + + + + Table Entry of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + Cell of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + Table of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::WORKHOLDING_ID)}} + + + + + + + Table Entry of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + Cell of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + Table of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::WORK_OFFSET)}} + + + + + + + Table Entry of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + Cell of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + Table of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::OPERATING_SYSTEM)}} + + + + + + + Table Entry of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FIRMWARE)}} + + + + + + + Cell of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FIRMWARE)}} + + + + + + + Table of {{def(EventEnum::FIRMWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FIRMWARE)}} + + + + + + + Table Entry of {{def(EventEnum::APPLICATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::APPLICATION)}} + + + + + + + Cell of {{def(EventEnum::APPLICATION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::APPLICATION)}} + + + + + + + Table of {{def(EventEnum::APPLICATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::APPLICATION)}} + + + + + + + Table Entry of {{def(EventEnum::LIBRARY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LIBRARY)}} + + + + + + + Cell of {{def(EventEnum::LIBRARY)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LIBRARY)}} + + + + + + + Table of {{def(EventEnum::LIBRARY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LIBRARY)}} + + + + + + + Table Entry of {{def(EventEnum::HARDWARE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::HARDWARE)}} + + + + + + + Cell of {{def(EventEnum::HARDWARE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::HARDWARE)}} + + + + + + + Table of {{def(EventEnum::HARDWARE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::HARDWARE)}} + + + + + + + Table Entry of {{def(EventEnum::NETWORK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::NETWORK)}} + + + + + + + Cell of {{def(EventEnum::NETWORK)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::NETWORK)}} + + + + + + + Table of {{def(EventEnum::NETWORK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::NETWORK)}} + + + + + + + Table Entry of rotations about X, Y, and Z axes are expressed in A, B, + and C respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of rotations about X, Y, and Z axes are expressed in A, B, + and C respectively within a 3-dimensional vector. + + + + + + + Cell of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + + + + + + Cell of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + Table of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of rotations about X, Y, and Z axes are expressed in A, B, and C + respectively within a 3-dimensional vector. + + + + + + + Table Entry of translations along X, Y, and Z axes are expressed as x,y, + and z respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of translations along X, Y, and Z axes are expressed as x,y, + and z respectively within a 3-dimensional vector. + + + + + + + Cell of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + + + + + + Cell of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + Table of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of translations along X, Y, and Z axes are expressed as x,y, and z + respectively within a 3-dimensional vector. + + + + + + + Table Entry of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Table of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_KIND_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_STATUS)}} If unique identifier is + given, part status is for that individual. If group identifier is given + without a unique identifier, then the status is assumed to be for the + whole group. + + + + + + + Cell of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + Table of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_STATUS)}} If unique identifier is given, + part status is for that individual. If group identifier is given without + a unique identifier, then the status is assumed to be for the whole + group. + + + + + + + Table Entry of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + Cell of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + Table of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ALARM_LIMIT)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + Table of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_AGGREGATE_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Cell of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_KIND_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + Cell of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + Table of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ADAPTER_URI)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + Table of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_REMOVED)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + Table of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_CHANGED)}} + + + + + + + Table Entry of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Cell of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Table of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SPECIFICATION_LIMIT)}} + + + + + + + Table Entry of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + Cell of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + Table of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONNECTION_STATUS)}} + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + Cell of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + Table of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ADAPTER_SOFTWARE_VERSION)}} + + + + + + + Table Entry of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + Cell of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + Table of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SENSOR_ATTACHMENT)}} + + + + + + + Table Entry of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + Cell of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + Table of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CONTROL_LIMIT)}} + + + + + + + Table Entry of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + Cell of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + Table of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEVICE_ADDED)}} + + + + + + + Table Entry of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + Cell of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + Table of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MTCONNECT_VERSION)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + Table of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_OCCURRENCE_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Cell of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_GROUP_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table Entry of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Cell of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_UNIQUE_ID)}} If no + {{property(DataItem::subType)}} is specified, `UUID` is default. + + + + + + + Table Entry of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + Cell of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + Table of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTIVATION_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + Cell of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + Table of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::DEACTIVATION_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + Cell of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + Table of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TRANSFER_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Cell of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Table of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOAD_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Cell of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Table of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_PROCESSING_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Cell of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Table of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PROCESS_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::VALVE_STATE)}} + + + + + + + Cell of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::VALVE_STATE)}} + + + + + + + Table of {{def(EventEnum::VALVE_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::VALVE_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCK_STATE)}} + + + + + + + Cell of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCK_STATE)}} + + + + + + + Table of {{def(EventEnum::LOCK_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCK_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + Cell of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + Table of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::UNLOAD_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Cell of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Table of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CYCLE_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + Cell of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + Table of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::OPERATING_MODE)}} + + + + + + + Table Entry of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + Cell of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + Table of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ASSET_COUNT)}} + + + + + + + Table Entry of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + Cell of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + + + + + + Cell of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + Table of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MAINTENANCE_LIST)}} If + {{property(MaintenanceList::result::Interval)}} `key` is not provided, + it is assumed `ABSOLUTE`. If + {{property(MaintenanceList::result::Direction)}} `key` is not provided, + it is assumed `UP`. If {{property(MaintenanceList::result::Units)}} + `key` is not provided, it is assumed to be `COUNT`. + + + + + + + Table Entry of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Cell of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Table of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FIXTURE_ID)}} + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + Cell of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + Table of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::PART_COUNT_TYPE)}} + + + + + + + Table Entry of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + Cell of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + Table of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CLOCK_TIME)}} + + + + + + + Table Entry of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + Cell of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + Table of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::NETWORK_PORT)}} + + + + + + + Table Entry of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::HOST_NAME)}} + + + + + + + Cell of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::HOST_NAME)}} + + + + + + + Table of {{def(EventEnum::HOST_NAME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::HOST_NAME)}} + + + + + + + Table Entry of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Cell of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Table of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LEAK_DETECT)}} + + + + + + + Table Entry of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + Cell of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + Table of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::BATTERY_STATE)}} + + + + + + + Table Entry of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + Cell of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + Table of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::FEATURE_PERSISTENT_ID)}} + + + + + + + Table Entry of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + Cell of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + Table of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::SENSOR_STATE)}} + + + + + + + Table Entry of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + Cell of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + + + + + + Cell of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + Table of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular {{def(EventEnum::COMPONENT_DATA)}} If the + {{block(Component)}} multiplicity can be determined, the device model + **MUST** use a fixed set of {{block(Component)}}s. + {{block(ComponentData)}} **MUST** provide a {{block(DataItem)}} + {{block(Definition)}}. + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + Cell of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + + + + + + Cell of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + Table of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular representation of {{def(EventEnum::WORK_OFFSETS)}} + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + Cell of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + + + + + + Cell of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + Table of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular representation of {{def(EventEnum::TOOL_OFFSETS)}} + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + Cell of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + + + + + + Cell of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + Table of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of tabular representation of + {{def(EventEnum::FEATURE_MEASUREMENT)}} {{block(FeatureMeasurement)}} + **MAY** include a {{term(characteristic)}} in which case it **MAY** + include a `CHARACTERISTIC_STATUS`. + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_PERSISTENT_ID)}} + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + Table of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MEASUREMENT_TYPE)}} Examples: `POINT`, + `RADIUS`, `ANGLE`, `LENGTH`, etc. + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + Table of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MEASUREMENT_VALUE)}} + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Table of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::MEASUREMENT_UNITS)}} + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::CHARACTERISTIC_STATUS)}} + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + Table of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::UNCERTAINTY_TYPE)}} + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + Table of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::UNCERTAINTY)}} + + + + + + + Table Entry of See {{sect(AlarmLimits)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of See {{sect(AlarmLimits)}}. + + + + + + + Cell of See {{sect(AlarmLimits)}}. + + + + + + + + + + + + + + Cell of See {{sect(AlarmLimits)}}. + + + + + + + Table of See {{sect(AlarmLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of See {{sect(AlarmLimits)}}. + + + + + + + Table Entry of See {{sect(ControlLimits)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of See {{sect(ControlLimits)}}. + + + + + + + Cell of See {{sect(ControlLimits)}}. + + + + + + + + + + + + + + Cell of See {{sect(ControlLimits)}}. + + + + + + + Table of See {{sect(ControlLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of See {{sect(ControlLimits)}}. + + + + + + + Table Entry of See {{sect(SpecificationLimits)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of See {{sect(SpecificationLimits)}}. + + + + + + + Cell of See {{sect(SpecificationLimits)}}. + + + + + + + + + + + + + + Cell of See {{sect(SpecificationLimits)}}. + + + + + + + Table of See {{sect(SpecificationLimits)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of See {{sect(SpecificationLimits)}}. + + + + + + + Table Entry of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + Cell of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + Table of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::TOOL_CUTTING_ITEM)}} + + + + + + + Table Entry of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + Cell of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + Table of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCATION_ADDRESS)}} + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + Cell of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + Table of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::ACTIVE_POWER_SOURCE)}} + + + + + + + Table Entry of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + Cell of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + Table of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCATION_NARRATIVE)}} + + + + + + + Table Entry of {{def(EventEnum::THICKNESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::THICKNESS)}} + + + + + + + Cell of {{def(EventEnum::THICKNESS)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::THICKNESS)}} + + + + + + + Table of {{def(EventEnum::THICKNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::THICKNESS)}} + + + + + + + Table Entry of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + Cell of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + + + + + + Cell of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + Table of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(EventEnum::LOCATION_SPATIAL_GEOGRAPHIC)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_FEED)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_CHANGE)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_RETRACT)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_LOAD)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::MATERIAL_UNLOAD)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_CHUCK)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::OPEN_DOOR)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + Cell of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + Table of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::PART_CHANGE)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_DOOR)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::CLOSE_CHUCK)}} + + + + + + + Table Entry of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Cell of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + + + + + + Cell of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Table of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(InterfaceEventEnum::INTERFACE_STATE)}} When the + {{block(InterfaceState)}} is `DISABLED`, the state of all data items + that are specific for the {{term(interaction model)}} associated with + that {{block(Interface)}} **MUST** be set to `NOT_READY`. + + + + + + + Table Entry of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ACCELERATION)}} + + + + + + + Cell of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ACCELERATION)}} + + + + + + + Table of {{def(SampleEnum::ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ACCELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Cell of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Table of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ACCUMULATED_TIME)}} + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE)}} + + + + + + + Cell of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AMPERAGE)}} + + + + + + + Table of {{def(SampleEnum::AMPERAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AMPERAGE)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGLE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGLE)}} + + + + + + + Cell of {{def(SampleEnum::ANGLE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGLE)}} + + + + + + + Table of {{def(SampleEnum::ANGLE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGLE)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Cell of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Table of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGULAR_ACCELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Cell of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Table of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGULAR_VELOCITY)}} + + + + + + + Table Entry of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Cell of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Table of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AXIS_FEEDRATE)}} + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Cell of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Table of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CAPACITY_FLUID)}} + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Cell of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Table of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CAPACITY_SPATIAL)}} + + + + + + + Table Entry of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Cell of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Table of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CONCENTRATION)}} + + + + + + + Table Entry of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Cell of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Table of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CONDUCTIVITY)}} + + + + + + + Table Entry of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Cell of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Table of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CUTTING_SPEED)}} + + + + + + + Table Entry of {{def(SampleEnum::DENSITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DENSITY)}} + + + + + + + Cell of {{def(SampleEnum::DENSITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DENSITY)}} + + + + + + + Table of {{def(SampleEnum::DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DENSITY)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_ACCELERATION_VOLUMETRIC)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_DENSITY)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_MASS)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_RATE_VOLUMETRIC)}} + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Table of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEPOSITION_VOLUME)}} + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT)}} + + + + + + + Table Entry of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Cell of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Table of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ELECTRICAL_ENERGY)}} + + + + + + + Table Entry of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Cell of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Table of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::EQUIPMENT_TIMER)}} + + + + + + + Table Entry of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Cell of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Table of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FILL_LEVEL)}} + + + + + + + Table Entry of {{def(SampleEnum::FLOW)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FLOW)}} + + + + + + + Cell of {{def(SampleEnum::FLOW)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FLOW)}} + + + + + + + Table of {{def(SampleEnum::FLOW)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FLOW)}} + + + + + + + Table Entry of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FREQUENCY)}} + + + + + + + Cell of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FREQUENCY)}} + + + + + + + Table of {{def(SampleEnum::FREQUENCY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FREQUENCY)}} + + + + + + + Table Entry of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Cell of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Table of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::GLOBAL_POSITION)}} + + + + + + + Table Entry of {{def(SampleEnum::LENGTH)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LENGTH)}} + + + + + + + Cell of {{def(SampleEnum::LENGTH)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LENGTH)}} + + + + + + + Table of {{def(SampleEnum::LENGTH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LENGTH)}} + + + + + + + Table Entry of {{def(SampleEnum::LEVEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LEVEL)}} + + + + + + + Cell of {{def(SampleEnum::LEVEL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LEVEL)}} + + + + + + + Table of {{def(SampleEnum::LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LEVEL)}} + + + + + + + Table Entry of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Cell of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Table of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LINEAR_FORCE)}} + + + + + + + Table Entry of {{def(SampleEnum::LOAD)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::LOAD)}} + + + + + + + Cell of {{def(SampleEnum::LOAD)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::LOAD)}} + + + + + + + Table of {{def(SampleEnum::LOAD)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::LOAD)}} + + + + + + + Table Entry of {{def(SampleEnum::MASS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::MASS)}} + + + + + + + Cell of {{def(SampleEnum::MASS)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::MASS)}} + + + + + + + Table of {{def(SampleEnum::MASS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::MASS)}} + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE)}} + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PATH_FEEDRATE_PER_REVOLUTION)}} + + + + + + + Table Entry of Example + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of Example + + + + + + + Cell of Example + + + + + + + + + + + + + + Cell of Example + + + + + + + Table of Example + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of Example + + + + + + + Table Entry of {{def(SampleEnum::PH)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PH)}} + + + + + + + Cell of {{def(SampleEnum::PH)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PH)}} + + + + + + + Table of {{def(SampleEnum::PH)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PH)}} + + + + + + + Table Entry of {{def(SampleEnum::POSITION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::POSITION)}} + + + + + + + Cell of {{def(SampleEnum::POSITION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::POSITION)}} + + + + + + + Table of {{def(SampleEnum::POSITION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::POSITION)}} + + + + + + + Table Entry of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Cell of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Table of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::POWER_FACTOR)}} + + + + + + + Table Entry of Description + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of Description + + + + + + + Cell of Description + + + + + + + + + + + + + + Cell of Description + + + + + + + Table of Description + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of Description + + + + + + + Table Entry of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Cell of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Table of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PROCESS_TIMER)}} + + + + + + + Table Entry of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::RESISTANCE)}} + + + + + + + Cell of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::RESISTANCE)}} + + + + + + + Table of {{def(SampleEnum::RESISTANCE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::RESISTANCE)}} + + + + + + + Table Entry of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Cell of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Table of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ROTARY_VELOCITY)}} + + + + + + + Table Entry of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Cell of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Table of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SOUND_LEVEL)}} + + + + + + + Table Entry of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Cell of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Table of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SPINDLE_SPEED)}} + + + + + + + Table Entry of {{def(SampleEnum::STRAIN)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::STRAIN)}} + + + + + + + Cell of {{def(SampleEnum::STRAIN)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::STRAIN)}} + + + + + + + Table of {{def(SampleEnum::STRAIN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::STRAIN)}} + + + + + + + Table Entry of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Cell of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Table of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TEMPERATURE)}} + + + + + + + Table Entry of {{def(SampleEnum::TENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TENSION)}} + + + + + + + Cell of {{def(SampleEnum::TENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TENSION)}} + + + + + + + Table of {{def(SampleEnum::TENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::TILT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TILT)}} + + + + + + + Cell of {{def(SampleEnum::TILT)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TILT)}} + + + + + + + Table of {{def(SampleEnum::TILT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TILT)}} + + + + + + + Table Entry of {{def(SampleEnum::TORQUE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::TORQUE)}} + + + + + + + Cell of {{def(SampleEnum::TORQUE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::TORQUE)}} + + + + + + + Table of {{def(SampleEnum::TORQUE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::TORQUE)}} + + + + + + + Table Entry of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VELOCITY)}} + + + + + + + Cell of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VELOCITY)}} + + + + + + + Table of {{def(SampleEnum::VELOCITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VELOCITY)}} + + + + + + + Table Entry of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VISCOSITY)}} + + + + + + + Cell of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VISCOSITY)}} + + + + + + + Table of {{def(SampleEnum::VISCOSITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VISCOSITY)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE)}} + + + + + + + Cell of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLTAGE)}} + + + + + + + Table of {{def(SampleEnum::VOLTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLTAGE)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLT_AMPERE_REACTIVE)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Cell of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Table of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLUME_FLUID)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Cell of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Table of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLUME_SPATIAL)}} + + + + + + + Table Entry of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::WATTAGE)}} + + + + + + + Cell of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::WATTAGE)}} + + + + + + + Table of {{def(SampleEnum::WATTAGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::WATTAGE)}} + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Table of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AMPERAGE_DC)}} + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Table of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::AMPERAGE_AC)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Table of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLTAGE_AC)}} + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Table of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::VOLTAGE_DC)}} + + + + + + + Table Entry of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Cell of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Table of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::X_DIMENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Cell of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Table of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::Y_DIMENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Cell of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Table of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::Z_DIMENSION)}} + + + + + + + Table Entry of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DIAMETER)}} + + + + + + + Cell of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DIAMETER)}} + + + + + + + Table of {{def(SampleEnum::DIAMETER)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DIAMETER)}} + + + + + + + Table Entry of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ORIENTATION)}} + + + + + + + Cell of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ORIENTATION)}} + + + + + + + Table of {{def(SampleEnum::ORIENTATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ORIENTATION)}} + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Table of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::HUMIDITY_RELATIVE)}} + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Table of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::HUMIDITY_ABSOLUTE)}} + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Table of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::HUMIDITY_SPECIFIC)}} + + + + + + + Table Entry of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Cell of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Table of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::PRESSURIZATION_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DECELERATION)}} + + + + + + + Cell of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DECELERATION)}} + + + + + + + Table of {{def(SampleEnum::DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DECELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Table of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ASSET_UPDATE_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Cell of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Table of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::ANGULAR_DECELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Table of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::OBSERVATION_UPDATE_RATE)}} + + + + + + + Table Entry of The force per unit area measured relative to a vacuum. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of The force per unit area measured relative to a vacuum. + + + + + + + Cell of The force per unit area measured relative to a vacuum. + + + + + + + + + + + + + + Cell of The force per unit area measured relative to a vacuum. + + + + + + + Table of The force per unit area measured relative to a vacuum. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of The force per unit area measured relative to a vacuum. + + + + + + + Table Entry of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::OPENNESS)}} + + + + + + + Cell of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::OPENNESS)}} + + + + + + + Table of {{def(SampleEnum::OPENNESS)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::OPENNESS)}} + + + + + + + Table Entry of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DEW_POINT)}} + + + + + + + Cell of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DEW_POINT)}} + + + + + + + Table of {{def(SampleEnum::DEW_POINT)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DEW_POINT)}} + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: $$Mass\times + GravitationalAcceleration$$ + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_FORCE)}} > Note: + $$Mass\times GravitationalAcceleration$$ + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::GRAVITATIONAL_ACCELERATION)}} + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Cell of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Table of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::BATTERY_CAPACITY)}} + + + + + + + Table Entry of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Table of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISCHARGE_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Cell of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Table of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::CHARGE_RATE)}} + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Cell of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Table of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::BATTERY_CHARGE)}} + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR)}} + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_LINEAR)}} + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::SETTLING_ERROR_ANGULAR)}} + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR)}} + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_ANGULAR)}} + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::FOLLOWING_ERROR_LINEAR)}} + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_LINEAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + + + + + + Cell of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::DISPLACEMENT_ANGULAR)}} > Note: The + displacement vector **MAY** be defined by the motion of the owning + {{block(Component)}}. + + + + + + + Table Entry of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + Constraints for Cell Values + + + + + + + + + + + Table Entry of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + Cell of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + + + + + + Cell of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + Table of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + + + Constraints for Entry Values + + + + + + + + The number of entries + + + + + + + + + + Table of {{def(SampleEnum::POSITION_CARTESIAN)}} + + + + + + + The description of the Condition + + + + + + + + The device's severity + + + + + + + + Identifier of an individual condition activation provided by a piece of + equipment + + + + + + + + A qualifier for the condition + + + + + + + The value is too high + + + + + + + The value is too low + + + + + + + + + Description + + + + + + + + + type of the power source. + + + + + + + The component specific Notifcation code + + + + + + + The component specific Notifcation code + + + + + + + An optional attribute that helps qualify the condition + + + + + + + The statistical operation on this data + + + + + + + + + + Description + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + + Identifier of an individual condition activation provided by a + piece of equipment + + + + + + + + + + Condition that has transitioned from Normal to either Warning or Fault + + + + + + + The conditon can not be determined. + + + + + + + + + + The conditon can not be determined. + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + + + + {{term(condition state)}} that indicates operation within specified + limits. + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + + + + {{term(condition state)}} that requires concern and supervision and may + become hazardous if no action is taken. + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + + + + {{term(condition state)}} that requires intervention to continue + operation to function properly. + + + + + + + DEPRECATED: An Notifcation code as defined by the component + + + + + + + + DEPRECATED: Types of Notifcations + + + + + + + A failure + + + + + + + A fault occurred + + + + + + + A spindle crash + + + + + + + A component has jammed + + + + + + + The component has been overloaded + + + + + + + E-Stop was pushed + + + + + + + A material failure has occurred + + + + + + + An operators message. Used with INFO severity + + + + + + + Another Notifcation type + + + + + + + + + DEPRECATED: The active or cleared state of the notification + + + + + + + The notification is active + + + + + + + The notification has been cleared + + + + + + + + + level of severity on a scale of 1-10. + + + + + + + The notification is critical + + + + + + + An error has occurred + + + + + + + A medium level notification that should be observed + + + + + + + This notification is for information purposes only + + + + + + + + + {{def(EventEnum::ALARM)}} + + + + + + + + {{def(EventEnum::CODE)}} + + + + + + + level of severity on a scale of 1-10. + + + + + + + The state + + + + + + + The component specific Notifcation code + + + + + + + + + + {{def(EventEnum::ALARM)}} + + + + + + + The possible values for an interface event + + + + + + + The value is unavailable + + + + + + + The interface is not ready + + + + + + + The interface is ready + + + + + + + The interface is actively executing + + + + + + + The interface has completed the action + + + + + + + The interface action has failed + + + + + + + + + An abstract interface event + + + + + + + + + + + + + + An abstract interface event + + + + + + + The state of the interface + + + + + + + The value is unavailable + + + + + + + The interface is enabled + + + + + + + The interface is disabled + + + + + + \ No newline at end of file