Notifications
You must be signed in to change notification settings - Fork 232
/
CHANGELOG
196 lines (172 loc) · 10.7 KB
/
CHANGELOG
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
Changes to version 2.3.2
------------------------
- TLS support now requires mbedtls 2.28
- updated HAL layer
- Added new IEC 62351-3 related TLS features (session resumption, alarms, ...)
- CS101 balanced link layer: Send request-status-of-link before calling reset-of-remote-link
- CS101 unbalanced master: Send request-status-of-link before calling reset-of-remote-link, added delay before repeating request-status-of-link
- added function CS101_ASDU_clone
- fixed - TLS: configured CRL are ignored (#117)
- integrated code to serve files
- other small bug fixes and improvements
- CS104 client: added connection event when connect failed
Changes to version 2.3.1
------------------------
- TLS support now requires mbedtls 2.16.12
- CS104 client/master: add support to specify local interface/IP address
- Macos HAL layer: replaced semaphores by mutex
- updated HAL layer
- fix - Possible buffer overflow when formatting IPv6 addresses (#96)
- fixed - write to queueEntry is not protected (#99)
- fixed bug in CS101_ASDU_setNumberOfElements (#91)
- CS104 slave: fixed problem in TEST-FR con timeout handling
- CS101 master: fixed problem not sending broadcast messages (#88)
- CS101 slave: fixed potential crash when application layer parameters don't match
- CS104 server: fixed - receiving I or S frame while in STOPDT should close connection
Changes to version 2.3.0
------------------------
- CS104 slave: send time sync response only to requesting client (#87)
- fixed a bug in StatusAndStatusChangeDetection type decoding
- fixed problem in TLS integration layer
- fixed wrong type in return value of TestCommandWithCP56Time2a_getCounter
- CS104 slave: close all open connections when server is stopped in non-treaded mode
- added QueryLog (F_SC_NB_1) information object type
- CS 101 slave: release plugin list in destroy function (#80)
- CS104 client: Added function CS104_Connection_sendTestCommandWithTimestamp to send C_TS_TA_1 test command
- CS104 slave: added support to handle test command C_TS_TA_1
- added missing value for IEC60870_QCC_FRZ_COUNTER_RESET (#78)
- CS104 slave: remove message from queue when confirmation received (see #77)
- CS104 master: confirm all received I messages before sending STOPDT ACT or closing the connection
- CS 104 slave: fixed bugs when TLS connection initilization fails (#75)
- fixed potential memory leak in CS104_Connection_connectAsync
- fixed wrong argument type of StepCommandWithCP56Time2a_destroy (#74)
- single point and double point information objects ignore invalid quality flags (#72)
Changes to version 2.2.1
------------------------
- CS104 slave: fixed problems in queue handling (#67)
- added missing return statement in CS101_ASDU_addPayload(#68)
- CS101_ASDU_addInformationObject now checks for correct object type
- windows socket driver: fixed - fail to detect peer close when read from socket
- fixed bug in BitString32 encoding (see #65)
- fixed - null pointer access when calling CS104_Slave_destroy without server running before (issue #64)
- added Bitstring32X_createEx functions to keep API backward compatible and allow setting of quality (issue #63)
Changes to version 2.2.0
------------------------
- CS 101/104 slave: improved stability when receiving corrupted messages
- CS 101/104 slave: added plugin interface
- CS101 master: fixed setting of own address in balanced mode (#51)
- CS101 slave: fixed bug in queue size initialization
- Socket HAL (linux/bsd): set default backlog to 2 (see #50)
- Socket HAL (linux/bsd): Socket_read detects closed socket
- fixed bugs in file handling messages
- fixed bug in OA decoding
- add support to create and handle private or not supported ASDU types
- CS104 master/slave: improved socket handling
- CS104 slave: improved memory handling and memory consumption
- removed CONFIG_CS104_SLAVE_POOL (and related) configuration option
Changes to version 2.1.1
------------------------
- CS 104 slave: added functions IMasterConnection_getPeerAddress and IMasterConnection_close
- CS 101/CS 104 slave: set P/N=1 (negative) when sending COT=44 or COT=45
- improved compatibility with VxWorks
- CS 104 slave: fixed bug in counter interrogation command handling - free stack allocated memory
- fixed some include file problems
Changes to version 2.1.0
------------------------
- CS104 slave: added support for multiple redundancy groups
- added non-threaded moded for CS 104 slave
- separated thread and semaphore support for CS 104 slave
- CS101 unbalanced link layer (master): automatically send request UD 1 when ACD bit is set in received frame
- added CS101_ASDU_getElementEx function to avoid dynamic memory allocation
- added support for static ASDU object allocation
- fixed length check when parsing M_EP_TD_1
- CS101 unbalanced master: fixed state machine problem with multiple slaves (some responses don't change state and master keeps locked on the slave)
- optionally compile library without HAL to simply using together with libiec61850
Changes to version 2.0.2
------------------------
- CS104 slave: added new CS104_ConnectionEventHandler to track connection events
- CS104 master/slave: added callback handlers to log raw messages
- CS101 master/slave: added callback handlers to log raw messages
Changes to version 2.0.1
------------------------
- fixed problems to compile code with C++
- CS101: added functions to better control link layer addresses
- CS101 master: added function to modify default link layer parameters
- link layer: fixed problem in test function handling
- application layer: allow configuration of maximum size of ASDU
- CS104 master: added new function CS104_Master_sendProcessCommandEx
- CS104: fixed timeout T2 problem
- and other small fixes
Changes to version 2.0.0
------------------------
- added support for CS 101 balanced and unbalanced serial link layer
- added serial port abstraction layer and implementations for linux and windows
- seperated lib60870-C and lib60870.NET into separate projects. Removed all .NET code from the lib60870 main branch
- added TLS support for CS 104
- API redesign. Not compatible with old API.
- updated and extended user guide
- added doxygen based API reference documentation
- added more examples
Changes to version 0.9.5
------------------------
- lib60870.NET: add support for server allowing multiple clients using the application layer (ServerMode.CONNECTION_IS_REDUNDANCY_GROUP)
- lib60870-C: add support for server allowing multiple clients using the application layer (new mode where each client connection is a redundancy group)
- lib60870-C: limit the number of allowed client connection (T104Slave_setMaxOpenConnections)
- lib60870-C: only accept single active connection in ServerMode == SINGLE_REDUNDANCY_GROUP
- lib60870-C: enhanced big endian platform detection
- lib60870-C: CS104 slave/server: added support for ConnectionRequestHandler
- lib60870-C: Socket_getPeerAddress replaced by Socket_getPeerAddressStatic to avoid dynamic memory allocation
- lib60870.NET: server support for multiple clients with separate ASDU queues (added ServerMode property)
- lib60870.NET: server - added MaxOpenConnections property
- lib60870.NET: server - added ConnectionRequestHandler
- lib60870.NET: Added RawValue properties to SetpointCommandNormalized and MeasuredValueNormalized, additional constructors with short values
- lib60870.NET: ScaledValue adds proporty to get/set short value
- lib60870.NET: fixed tests project dependencies
- lib60870.NET: fixed bug in BitString32
- lib60870-C: fixed month bug in CP56Time2a conversion functions
Changes to version 0.9.4
------------------------
- added length check when adding information objects to ASDUs --> changed signature of ASDU_addInformationObject
- lib60870-C: added TARGET=UCLINUX-XPORT to compile for Lantronix XPORT PRO
- lib60870-C: added CauseOfTransmission_toString function
- lib60870.NET: fixed bug in parsing of MeasuredValueNormalizedWithoutQuality when SEQ = 1
- added all missing timeout handling for master and slave side
- lib60870.NET: added client side ConnectionStatistics
- lib60870.NET: client socket uses Poll instead of read timeout
- lib60870.NET: added TestCommand ASDU
- lib60870.NET: client - some refactoring - added ASDU queue for congestion handling
- lib60870.NET: fixed constructors for StepPosition information objects (added quality)
- lib60870.NET: Added missing GetEncodedSize in SinglePointWithCPxxx objects
- lib60870.NET: added constructors and set properties for CP24Time2a
- lib60870-C: implemented BufferFrame to enable ASDU and IO encoding to arbitrary memory buffers
- lib60870-C: slave - replaced ASDU queue by queue consisiting of buffers of encoded ASDUs
- lib60870.NET: fixed bug in encoding of sequence of information objects
- lib60870.NET: fixed bug in EventOfProtectionEquipment
- lib60870.NET: added public constructor for CP16Time2a
- lib60870.NET: added encoding tests (with maximum number of information objects in ASDU w/wo sequence of information objects)
- lib60870.NET: fixed bug in StatusAndStatusChangeDetection
- lib60870.NET: ASDU parser - added header length check
Changes to version 0.9.3
------------------------
- lib60870.NET: changed visibility of InformationObject.Encode method to internal
- lib60870.NET: added public Constructor Encoding functions for PackedOutputCircuitInfo, PackedStartEventsOfProtectionEquipment, EventOfProtectionEquipment
- lib60870.NET/lib60870-C: Added parsing support for sequence for information objects for all data messages in monitoring direction (despite the fact that this should not happen according to IEC 60870-5-101)
Changes to version 0.9.2
------------------------
- lib60870-C: changed to select based read at client side
- lib60870.NET: extended STARTDT/STOPDT handling
- lib60870.NET: changed signature of ConnectionHandler
- lib60870-C: added functions to bind to local IP address and TCP port
- lib60870-C: default bind to address "0.0.0.0"
- lib60780-C: fixed StopDT bug
- lib60870-C: fixed C99 incompatibilities in cpXXtime2a.c
- lib60870-C: added support for M_EI_NA_1 message (end of initialization)
- lib60870-C: DoublePointWithCP56Time2a_getFromBuffer corrected parsing of time stamp
- lib60870-C: SingleCommandWithCP56Time2a_getFromBuffer corrected parsing of time stamp
- lib60870-C: SinglePointWithCP56Time2a_getFromBuffer corrected parsing of time stamp
- lib60870-C: StepPositionWithCP56Time2a_getFromBuffer corrected parsing of time stamp
- lib60870-C: DoublePointWithCP24Time2a_getFromBuffer corrected parsing of time stamp
- lib60870-C: SinglePointWithCP24Time2a_getFromBuffer corrected parsing of time stamp
- lib60870-C: corrected parsing of double point information
- lib60870-C: corrected parsing of some data types when sent as sequence of information objects
- lib60870-C: client/master: extended STARTDT/STOPDT handling; changed connection handler signature to indicate STARTDT_CON/STOPDT_CON messages