"DEBUG: Frame check failed, ignoring!!" on SE6K and SDM630 V2 #16
Comments
Can anyone help mee with this? I've tried to set framer = rtu in [server] section but it didn't help. |
Ok,
Data from meter look very strange. What should check? |
Correct. When the SE is a master polling meters it will switch back to 9600 baud, irrespective of the baudrate you set when the SE is in Sunspec mode.
It would be useful to have the Also, could you note the settings with which you have configured the meter on the SE? |
Thank you for your response. I've attached log file.
I've set up meter as WattNode. I was following up your instructions. |
I think that this output is from try with your static data (from another issue).
|
So a quick glance tells me two things: (1) the SDM630 is responding as expected and is providing sensible readings, and (2) the SE is communicating with It would be helpful to know whether the SE asks for blocks 1651 and 1701 at any point, most probably after (re)booting. If so, this means the SE is able to receive and decode the responses. When the SE is satisfied we would expect it to start polling 1001 and 1101 multiple times per second. Looks like the SE isn't happy, and never gets to that stage. This would suggest something is missing, or incorrect in blocks 1601, 1651 or 1701. |
Thank you for replay. This is list of register SE is asking for:
And first few seconds of output:
|
And my current meter congig looks like this:
I was playing with some values but without success |
Hi,
Im trying to run tool but I've got error message likethis:
My config (kemp-rtu.conf):
I'm using semp-rtu.py
I can confirm that connection with SDM meter is working correctly.
What am I doing wrong?
The text was updated successfully, but these errors were encountered: