On 16 july 2023 we received a mail from OVH to tell us :
- ping was lost on ovh3 at 19:31
- an intervention took place, that ended at 19:44
Content of the intervention:
Serveur 'freezé' sur "Kernel panic - not syncing". Pas de réponse clavier.
Actions : Nous avons effectué un redémarrage. Test hardware en échec : Le disque SN :5PHAUL7F est défectueux. RAM : OK. Cooling : OK. Redémarrage du serveur.
Le serveur est démarré sur disque et est sur l'écran de connexion. Ping OK et les services sont ouverts.
Recommandations : Merci de bien vouloir procéder à une sauvegarde de vos données et de contacter le support afin de remplacer le > disque défectueux.
Additional details : SMART_ATA_ERROR : SMART ATA errors found on disk 5PHAUL7F (Total : 2)
So they tell us they will replace the disk when we are ready (backups done).
Note: to find the ticket back:
- gone to https://help.ovhcloud.com/csm/fr-home?id=csm_index
- signed in
- followed entry "tickets" under search bar
- "notification services" in tickets
On 2023-07-17.
I did a backup of /etc on ovh3 and copied it to off2.
I tell OVH I was ready for the intervention through OVH console:
- added all requested informations
- I got disk serial number with
udevadm info --query=all --name=/dev/sdc | grep ID_SERIAL
- for RAID status I put the result of
sudo zpool status
- added reference of incident and PDF of it
- I got disk serial number with
- ticket CS8088256 was created
I proposed to make the change the same day between 15:00 and 17:00 UTC.
I later got confirmation for that schedule from OVH team.
At 14:30 UTC, I changed CNAME entry for images.openfoodfacts.org to point to off1.
At 17:03 (15:03 UTC) I received a mail telling the operation will take place after 15min
At 17:23 I received a mail telling me the server was rebooted in rescue mode
I ssh the server but realized rescue mode was not useful to me.
So I go in OVH console, change boot type to disk, and ask for cold reboot.
Now I ssh ovh3, and started a root session.
zpool status is as expected
# zpool status
pool: rpool
state: DEGRADED
status: One or more devices could not be used because the label is missing or
invalid. Sufficient replicas exist for the pool to continue
functioning in a degraded state.
action: Replace the device using 'zpool replace'.
see: https://openzfs.github.io/openzfs-docs/msg/ZFS-8000-4J
scan: scrub in progress since Sun Jul 16 23:21:45 2023
6.99T scanned at 1.20G/s, 6.68T issued at 0B/s, 32.1T total
0B repaired, 20.80% done, no estimated completion time
config:
NAME STATE READ WRITE CKSUM
rpool DEGRADED 0 0 0
raidz2-0 DEGRADED 0 0 0
sda ONLINE 0 0 0
sdb ONLINE 0 0 0
17844476680277185950 UNAVAIL 0 0 0 was /dev/sdc1
sdd ONLINE 0 0 0
sde ONLINE 0 0 0
sdf ONLINE 0 0 0
logs
nvme0n1p4 ONLINE 0 0 0
cache
nvme0n1p5 ONLINE 0 0 0
errors: No known data errors
And new sdc is here.
lsblk
…
sdb 8:16 0 10,9T 0 disk
├─sdb1 8:17 0 10,9T 0 part
└─sdb9 8:25 0 8M 0 part
sdc 8:32 0 10,9T 0 disk
sdd 8:48 0 10,9T 0 disk
├─sdd1 8:49 0 10,9T 0 part
└─sdd9 8:57 0 8M 0 part
…
Added a gpt label to sdc (not sure if useful)
parted /dev/sdc
(parted) mklabel
New disk label type? gpt
Then followed https://askubuntu.com/questions/172577/replacing-a-disk-in-zpool
zpool offline rpool 17844476680277185950
zpool replace rpool /dev/sdc
# zpool status
pool: rpool
state: DEGRADED
status: One or more devices is currently being resilvered. The pool will
continue to function, possibly in a degraded state.
action: Wait for the resilver to complete.
scan: resilver in progress since Mon Jul 17 16:27:48 2023
599G scanned at 3.54G/s, 1.80G issued at 10.9M/s, 32.1T total
0B resilvered, 0.01% done, 35 days 15:39:43 to go
config:
NAME STATE READ WRITE CKSUM
rpool DEGRADED 0 0 0
raidz2-0 DEGRADED 0 0 0
sda ONLINE 0 0 0
sdb ONLINE 0 0 0
replacing-2 DEGRADED 0 0 0
17844476680277185950 OFFLINE 0 0 0 was /dev/sdc1/old
sdc ONLINE 0 0 0
sdd ONLINE 0 0 0
sde ONLINE 0 0 0
sdf ONLINE 0 0 0
logs
nvme0n1p4 ONLINE 0 0 0
cache
nvme0n1p5 ONLINE 0 0 0
errors: No known data errors
Later, at 18:51 it's more optimistic:
zpool status
pool: rpool
state: DEGRADED
status: One or more devices is currently being resilvered. The pool will
continue to function, possibly in a degraded state.
action: Wait for the resilver to complete.
scan: resilver in progress since Mon Jul 17 16:27:48 2023
1.78T scanned at 1.30G/s, 315G issued at 231M/s, 32.1T total
50.2G resilvered, 0.96% done, 1 days 16:09:43 to go
Finally it ended on 21/07 at 13:43. an email was sent:
ZFS has finished a resilver:
eid: 36209
class: resilver_finish
host: ovh3
time: 2023-07-21 11:43:09+0000
pool: rpool
state: DEGRADED
scan: resilvered 5.65T in 3 days 19:15:21 with 0 errors on Fri Jul 21 11:43:09 2023
config:
NAME STATE READ WRITE CKSUM
rpool DEGRADED 0 0 0
raidz2-0 DEGRADED 0 0 0
sda ONLINE 0 0 0
sdb ONLINE 0 0 0
replacing-2 DEGRADED 0 0 0
17844476680277185950 OFFLINE 0 0 0 was /dev/sdc1/old
sdc ONLINE 0 0 0
sdd ONLINE 0 0 0
sde ONLINE 0 0 0
sdf ONLINE 0 0 0
logs
nvme0n1p4 ONLINE 0 0 0
cache
nvme0n1p5 ONLINE 0 0 0
errors: No known data errors
So it took about 3 days and 18 hours.
To leviate pressure on OVH3 we wanted to serve images with off2.
First I wanted to use the off container to serve images. But as I see it would take more time than expected, and also because I might need to reboot the container, I decided to go straight and do it directly on the host (as on ovh3).
Installed nginx on off2:
apt update && apt install nginx certbot
Copied config and certificates from ovh3:
rsync -a [email protected]:/etc/letsencrypt/ /etc/letsencrypt/
rm -rf /etc/letsencrypt/*/ovh3.*
rsync -a [email protected]:/etc/nginx/acme.sh /etc/nginx
scp [email protected]:/etc/nginx/sites-enabled/static-off /etc/nginx/sites-available/
ln -s ../sites-available/static-off /etc/nginx/sites-enabled/
created a dataset for nginx logs as on ovh3:
zfs create zfs-hdd/logs-nginx
chown www-data:www-data /zfs-hdd/logs-nginx
Edited /etc/nginx/site-enabled/static-off
:
-
changed upstream ip:
upstream openfoodfacts { server 10.0.0.2:443 weight=100; server off1.openfoodfacts.org:443; …
-
replaced every rpool by zfs-hdd (%s/rpool/zfs-hdd/g)
tested with nginx -t
restart nginx:
systemctl restart nginx
Test from my machine by editing /etc/hosts
:
# images transfer on off2
213.36.253.208 images.openfoodfacts.org
and going to the website… works like a charm.
I then go to OVH console to change DNS CNAME entry of images.openfoodfacts.org
to point to off2.openfoodfacts.org
.