In my opinion the SLO-2 channel would be the best candidate for the next model generation and testing process. This channel has an important role in neuromuscular junctions in C. elegans, so we can start working on modeling channels in motorneurons. |
@VahidGh I've added an IV Curve test for the SLO-2 channel here, although you can see that the model/data agreement is pretty bad, compared to the EGL-19 channel shown here. I'm using Fig. 7B from 10.1113/jphysiol.2010.200683 for the data; which is the first entry that comes up in the channelworm DB; should I be using a different set of data? |
@rgerkin: Regarding scaling, I think considering some common expression system such as Fig. 7B from 10.1113/jphysiol.2010.200683, would be great when combining other channels and considering motoneuron cells in c. elegans. I guess it would be better to start with fig. 6a from 10.1038/77670 (or just figure ID=5, something like this new approach), as it is expressed and clamped lonely in I have also started some work for this channel here, and generated some initial model here using a fixed time-course (which is now possible to optimize it using a dynamic time-course using the most recent version of cwFitter). Although, the model generates the same I/V curve as shown in the paper, however, in order to build a precise model, encountered some problem due to having to consider [Cl], and didn't know how should I consider concentrations other than [Ca] using NeuroML/NEURON. |
@VahidGh I've added a notebook for SLO-2 here. Things look bad for the model at the moment. Can you identify any issue in the model I am using in that notebook? I've addressed scaling by auto-scaling the model output (by a constant) to match the data (new feature of NeuronUnit), since we have not only one but two degrees of freedom we can do nothing about (one is the surface area of the cell, and the other is the bulk conductance of the channels on the patch). This works fine for EGL-19, but for SLO-2 I had to turn it off because the model-data agreement is so bad the scaling algorithm wanted to reverse the sign of the model output! |
@rgerkin, What do you mean by > Things look bad for the model ? |
@VahidGh Yes, I mean things look bad for the |
From the data curated here, does anyone have any thoughts about which would be the best basis for the next few SciUnit tests? Considerations are: relevance to the model, orthogonality to previous tests, quality of data, etc.