OPI gRPC to Nvidia SDK bridge third party repo

Linters CodeQL OpenSSF Scorecard tests Docker License codecov Go Report Card Go Doc Pulls Last Release GitHub stars GitHub Contributors

This is a Nvidia app (bridge) to OPI APIs for storage, inventory, ipsec and networking (future).

I Want To Contribute

This project welcomes contributions and suggestions. We are happy to have the Community involved via submission of Issues and Pull Requests (with substantive content or even just fixes). We are hoping for the documents, test framework, etc. to become a community process with active engagement. PRs can be reviewed by by any number of people, and a maintainer may accept.

See CONTRIBUTING and GitHub Basic Process for more details.

Documentation

Getting started

build like this:

go build -v -o /opi-nvidia-bridge ./cmd/...

import like this:

import "github.com/opiproject/opi-nvidia-bridge/pkg/frontend"

FW config

for Nvme:

sudo mlxconfig -d /dev/mst/mt41686_pciconf0 s NVME_EMULATION_ENABLE=1
sudo mlxconfig -d /dev/mst/mt41686_pciconf0 s NVME_EMULATION_NUM_PF=2 NVME_EMULATION_NUM_VF=2

for VirtioBlk:

sudo mlxconfig -d /dev/mst/mt41686_pciconf0 s VIRTIO_BLK_EMULATION_ENABLE=1
sudo mlxconfig -d /dev/mst/mt41686_pciconf0 s VIRTIO_BLK_EMULATION_NUM_PF=2 VIRTIO_BLK_EMULATION_NUM_VF=2

And then power cycle your system.

For additional config options, see documentation

Snap Service

start from systemd:

sudo systemctl start mlnx_snap

or from container, see documentation

Make sure /var/tmp/spdk.sock is created. OPI bridge is using it to communicate with SNAP service.

Using docker

Before initiating the bridge, the Redis and Jaeger services must be operational. To specify non-standard ports for these services, use the --help command with the binary to find out which parameters needs to be passed.

on DPU/IPU (i.e. with IP=10.10.10.1) run

$ docker run --rm -it -v /var/tmp/:/var/tmp/ -p 50051:50051 ghcr.io/opiproject/opi-nvidia-bridge:main
2023/09/12 20:29:05 Connection to SPDK will be via: unix detected from /var/tmp/spdk.sock
2023/09/12 20:29:05 gRPC server listening at [::]:50051
2023/09/12 20:29:05 HTTP Server listening at 8082

on X86 management VM run

reflection

$ docker run --network=host --rm -it namely/grpc-cli ls --json_input --json_output localhost:50051
grpc.reflection.v1alpha.ServerReflection
opi_api.inventory.v1.InventorySvc
opi_api.security.v1.IPsec
opi_api.storage.v1.AioVolumeService
opi_api.storage.v1.FrontendNvmeService
opi_api.storage.v1.FrontendVirtioBlkService
opi_api.storage.v1.FrontendVirtioScsiService
opi_api.storage.v1.MiddleendService
opi_api.storage.v1.NvmeRemoteControllerService
opi_api.storage.v1.NullVolumeService

full test suite

docker run --rm -it --network=host docker.io/opiproject/godpu:main inventory get --addr="10.10.10.10:50051"
docker run --rm -it --network=host docker.io/opiproject/godpu:main storage test --addr="10.10.10.10:50051"
docker run --rm -it --network=host docker.io/opiproject/godpu:main ipsec test --addr=10.10.10.10:50151 --pingaddr=8.8.8.1"

run either gRPC or HTTP requests

# gRPC requests
docker run --network=host --rm -it namely/grpc-cli ls   --json_input --json_output 10.10.10.10:50051 -l
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmeSubsystem "{nvme_subsystem : {spec : {nqn: 'nqn.2022-09.io.spdk:opitest2', serial_number: 'myserial2', model_number: 'mymodel2', max_namespaces: 11} }, nvme_subsystem_id : 'subsystem2' }"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 ListNvmeSubsystems "{}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 GetNvmeSubsystem "{name : 'nvmeSubsystems/subsystem2'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmeController "{parent: 'nvmeSubsystems/subsystem2', nvme_controller : {spec : {nvme_controller_id: 2, pcie_id : {physical_function : 0, virtual_function : 0, port_id: 0}, max_nsq:5, max_ncq:5, 'trtype': 'NVME_TRANSPORT_TYPE_PCIE' } }, nvme_controller_id : 'controller1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 ListNvmeControllers "{parent : 'nvmeSubsystems/subsystem2'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 GetNvmeController "{name : 'nvmeSubsystems/subsystem2/nvmeControllers/controller1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmeNamespace "{parent: 'nvmeSubsystems/subsystem2', nvme_namespace : {spec : {volume_name_ref : 'Malloc0', 'host_nsid' : '10', uuid:{value : '1b4e28ba-2fa1-11d2-883f-b9a761bde3fb'}, nguid: '1b4e28ba-2fa1-11d2-883f-b9a761bde3fb', eui64: 1967554867335598546 } }, nvme_namespace_id: 'namespace1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 ListNvmeNamespaces "{parent : 'nvmeSubsystems/subsystem2'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 GetNvmeNamespace "{name : 'nvmeSubsystems/subsystem2/nvmeNamespaces/namespace1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 StatsNvmeNamespace "{name : 'nvmeSubsystems/subsystem2/nvmeNamespaces/namespace1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmeRemoteController "{nvme_remote_controller : {multipath: 'NVME_MULTIPATH_MULTIPATH'}, nvme_remote_controller_id: 'nvmetcp12'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 ListNvmeRemoteControllers "{}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 GetNvmeRemoteController "{name: 'nvmeRemoteControllers/nvmetcp12'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmePath "{parent: 'nvmeRemoteControllers/nvmetcp12', nvme_path: {traddr:'11.11.11.2', trtype:'NVME_TRANSPORT_TYPE_TCP', fabrics: {adrfam:'NVME_ADDRESS_FAMILY_IPV4', subnqn:'nqn.2016-06.com.opi.spdk.target0', trsvcid:'4444', hostnqn:'nqn.2014-08.org.nvmexpress:uuid:feb98abe-d51f-40c8-b348-2753f3571d3c'}}, nvme_path_id: 'nvmetcp12path0'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmeRemoteController "{nvme_remote_controller : {multipath: 'NVME_MULTIPATH_DISABLE'}, nvme_remote_controller_id: 'nvmepcie13'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 CreateNvmePath "{parent: 'nvmeRemoteControllers/nvmepcie13', nvme_path : {traddr:'0000:01:00.0', trtype:'NVME_TRANSPORT_TYPE_PCIE'}, nvme_path_id: 'nvmepcie13path0'}"

docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 ListNvmePaths "{parent : 'nvmeRemoteControllers/nvmepcie13'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmePath "{name: 'nvmeRemoteControllers/nvmepcie13/nvmePaths/nvmepcie13path0'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmeRemoteController "{name: 'volumes/nvmepcie13'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 GetNvmePath "{name: 'nvmeRemoteControllers/nvmepcie13'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmePath "{name: 'nvmeRemoteControllers/nvmetcp12/nvmePaths/nvmetcp12path0'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmeRemoteController "{name: 'nvmeRemoteControllers/nvmetcp12'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmeNamespace "{name : 'nvmeSubsystems/subsystem2/nvmeNamespaces/namespace1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmeController "{name : 'nvmeSubsystems/subsystem2/nvmeControllers/controller1'}"
docker run --network=host --rm -it namely/grpc-cli call --json_input --json_output 10.10.10.10:50051 DeleteNvmeSubsystem "{name : 'nvmeSubsystems/subsystem2'}"
# HTTP requests
# inventory
curl -kL http://10.10.10.10:8082/v1/inventory/1/inventory/2
# Nvme
# create
curl -X POST -f http://10.10.10.10:8082/v1/nvmeRemoteControllers?nvme_remote_controller_id=nvmetcp12 -d '{"multipath": "NVME_MULTIPATH_MULTIPATH"}'
curl -X POST -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12/nvmePaths?nvme_path_id=nvmetcp12path0 -d '{"traddr":"11.11.11.2", "trtype":"NVME_TRANSPORT_TYPE_TCP", "fabrics":{"subnqn":"nqn.2016-06.com.opi.spdk.target0", "trsvcid":"4444", "adrfam":"NVME_ADDRESS_FAMILY_IPV4", "hostnqn":"nqn.2014-08.org.nvmexpress:uuid:feb98abe-d51f-40c8-b348-2753f3571d3c"}}'
curl -X POST -f http://10.10.10.10:8082/v1/nvmeSubsystems?nvme_subsystem_id=subsys0 -d '{"spec": {"nqn": "nqn.2022-09.io.spdk:opitest1"}}'
curl -X POST -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeNamespaces?nvme_namespace_id=namespace0 -d '{"spec": {"volume_name_ref": "Malloc0", "host_nsid": 10}}'
curl -X POST -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeControllers?nvme_controller_id=ctrl0 -d '{"spec": {"trtype": "NVME_TRANSPORT_TYPE_TCP", "fabrics_id":{"traddr": "127.0.0.1", "trsvcid": "4421", "adrfam": "NVME_ADDRESS_FAMILY_IPV4"}}}'
# get
curl -X GET -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12
curl -X GET -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12/nvmePaths/nvmetcp12path0
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeNamespaces/namespace0
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeControllers/ctrl0
# list
curl -X GET -f http://10.10.10.10:8082/v1/nvmeRemoteControllers
curl -X GET -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12/nvmePaths
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeNamespaces
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeControllers
# stats
curl -X GET -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12:stats
curl -X GET -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12/nvmePaths/nvmetcp12path0:stats
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0:stats
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeNamespaces/namespace0:stats
curl -X GET -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeControllers/ctrl0:stats
# update
curl -X PATCH -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12 -d '{"multipath": "NVME_MULTIPATH_MULTIPATH"}'
curl -X PATCH -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12/nvmePaths/nvmetcp12path0 -d '{"traddr":"11.11.11.2", "trtype":"NVME_TRANSPORT_TYPE_TCP", "fabrics":{"subnqn":"nqn.2016-06.com.opi.spdk.target0", "trsvcid":"4444", "adrfam":"NVME_ADDRESS_FAMILY_IPV4", "hostnqn":"nqn.2014-08.org.nvmexpress:uuid:feb98abe-d51f-40c8-b348-2753f3571d3c"}}'
curl -X PATCH -k http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeNamespaces/namespace0 -d '{"spec": {"volume_name_ref": "Malloc1", "host_nsid": 10}}'
curl -X PATCH -k http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeControllers/ctrl0 -d '{"spec": {"trtype": "NVME_TRANSPORT_TYPE_TCP", "fabrics_id":{"traddr": "127.0.0.1", "trsvcid": "4421", "adrfam": "NVME_ADDRESS_FAMILY_IPV4"}}}'
# delete
curl -X DELETE -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeControllers/ctrl0
curl -X DELETE -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0/nvmeNamespaces/namespace0
curl -X DELETE -f http://10.10.10.10:8082/v1/nvmeSubsystems/subsys0
curl -X DELETE -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12/nvmePaths/nvmetcp12path0
curl -X DELETE -f http://10.10.10.10:8082/v1/nvmeRemoteControllers/nvmetcp12