diff --git a/docs/simulation/security/index.md b/docs/simulation/security/index.md index 8209612700c..316a57c686f 100644 --- a/docs/simulation/security/index.md +++ b/docs/simulation/security/index.md @@ -58,17 +58,22 @@ connected to a given bus bar section. Remedial actions are actions that are applied when limit violations occur. Supported actions are: -- Open or close a switch -- Open or close a terminal -- Change the tap of a tap changer (phase or ratio) -- Change the active and/or reactive power of a load (by setting the values, or defining changes in value or percentage) -- Change the section of a shunt compensator -- Change the regulation status of a tap changer -- Change `targetP`, `targetQ`, regulation status and `targetV` of a generator -- Change the regulation mode of a static var compensator and its associated set point. -- Enabled or disabled AC emulation for HVDC line (with the possibility to change `P0` and `droop` for AC emulation and - active power set point and converter mode for set point operating mode) -- Change the interchange target of an area by specifying a new interchange target in MW. +| Action | Description | +|------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| `LoadAction` | Change the relative of absolute `P0` and/or `Q0` of a load. | +| `DanglingLineAction` | Change the relative of absolute `P0` and/or `Q0` of a dangling line. | +| `SwitchAction` | Open or close a switch. | +| `TerminalsConnectionAction` | Open or close a terminal. | +| `PhaseTapChangerTapPositionAction` | Change the tap of a phase tap changer. | +| `RatioTapChangerTapPositionAction` | Change the tap of a ratio tap changer. | +| `PercentChangeLoadAction` | Change the active and/or reactive power of a load (by setting the values, or defining changes in value or percentage). | +| `ShuntCompensatorPositionAction` | Change the section of a shunt compensator. | +| `PhaseTapChangerRegulationAction` | Change the regulation status of a phase tap changer. | +| `RatioTapChangerRegulationAction` | Change the regulation status of a ratio tap changer. | +| `GeneratorAction` | Change `targetP`, `targetQ`, regulation status and `targetV` of a generator. | +| `StaticVarCompensatorAction` | Change the regulation mode of a static var compensator and its associated set point. | +| `HvdcAction` | Enabled or disabled AC emulation for HVDC line (with the possibility to change `P0` and `droop` for AC emulation and active power set point and converter mode for set point operating mode). | +| `AreaInterchangeTargetAction` | Change the interchange target of an area by specifying a new interchange target in MW. | Remedial actions can be *preventive* or *curative*: @@ -77,6 +82,8 @@ Remedial actions can be *preventive* or *curative*: - curative: these actions are implemented after a violation occurs, for example, if the flow of the monitored line is greater than `100%`. +Note: you can find the current list of remedial actions implemented in the PowSyBl Open Load Flow security analysis provider in the [PowSyBl Open Load Flow documentation](inv:powsyblopenloadflow:*:*#security/inputs). + ### Conditions Actions are applied if a condition is met. The conditions can be diversified and extended in the future: