TrainingThe training procedure borrows several aspects of the synthetic image generation procedure (described in the 1st comment) and adds the regular training hyperparameters. To keep it close to our contrast-agnostic model for SC, I set the output shape to When training for 5 epochs initially, the model encountered |
I was able to fix the Experiment 1The following hyperparameters are defined in this training script, which I have modified to stay close to our contrast-agnostic model for SC segmentation. The hyperparams defined below are the only ones changed for this experiment, rest all are set to their default values. n_neutral_labels = None # (setting this to an incorrect value is what I believe resulted in NaN values above
# shape and resolution of the outputs
target_res = None # SynthSeg by default outputs everything at 1mm iso; since we don't want that, it is set to None
output_shape = (64, 192, 256) # setting this to the original shape of the labels (192, 260, 320) resulted in OOM errors;
# the cropped output shape is also close to what we use in contrast-agnostic (64, 192, 320) i.e. heavy cropping on R-L dim.
# spatial deformation parameters
flipping = False
rotation_bounds = 20
shearing_bounds = .012
bias_field_std = .5
# architecture parameters
activation = 'relu' # we used relu, so changed it from 'elu' to 'relu'
# training parameters
dice_epochs = 25 # number of training epochs
steps_per_epoch = 1000 # number of iteration per epoch
batchsize = 2 ResultsWe see that the predictions are not good as they fail to capture the structure of the cervical spine. None of the labels (i.e. cord, CSF, vertebrae, discs, etc.) are properly segmented. |
Experiment 2Since Surprisingly, the model does not predict anything when |
Experiment 3To simplify the segmentation problem, I tried to re-train the model with only 2 output classes (i.e. those of the spinal cord and the CSF). Specifically, given all the following labels, the model is trained to output only the SC and CSF classes with label values 200 and 201 (keeping the rest of the hyperparams same as in Experiment 1) gen_labels_cerv_totalseg = np.array([0,
# vertebrae (covering C1 to T12)
41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23,
# discs (covering C1/C2 to T11/T12)
224, 223, 222, 221, 220, 219, 218, 217, 216, 215, 214, 213, 212, 211, 210, 209, 208,
# SC and CSF --> only output these labels
200, 201,
]) The model failed to output anything as we get empty predictions for all test images here as well ... Given the string of poor results, I am not sure what could be the actual reason for SynthSeg failing on SC images. One potential issue could be that, at test time, the input T1w images contain both brain and the SC (like any typical T1w SC image). However, the synthetic scans that SynthSeg generates during training only contains the images with 4 classes -- maybe this discrepancy is one issue? But, to fix this, it would mean that we need all the labels (i.e. for those of the brain and those of the SC, which is really impractical) |
indeed-- let's not go there |
This issue summarizes my attempt at training the SynthSeg on the spine-generic multi subject dataset.
Brief context: SynthSeg was originally proposed for the segmentation of brain scans of any resolution and contrast. Because is "contrast-agnostic", I am trying to re-train the model as a baseline for our contrast-agnostic spinal cord (SC) segmentation model. Important note here is that SynthSeg required fully-labeled brain scans from which it synthesizes fake brain images (sampled from a GMM) and then trains the segmentation model. A notable challenge in re-training SynthSeg for SC images is that it would require all the labels in a SC scan (i.e. those of SC, cerebrospinal fluid, vertebrae, bones, brain, etc.)
As it is not feasible to obtain labels for each anatomical region in a SC image, I tried to ease the constraints by only focusing on the segmentations of 4 parts: (i) vertebrae, (ii) discs, (iii) SC, and (iv) cerebrospinal fluid (CSF). The labels for these regions were obtained using the TotalSegmentatorMRI model.
Experiments
The SynthSeg repo contains well-described tutorials for re-training your own models. The following sections will describe how I have tweaked SynthSeg for SC data.
Defining the labels for generating synthetic images
There are 4 key elements in generating synthetic images based on labels:
These are essentially the 4 key parameters in the procedure for generating synthetic images from the GMM.
The text was updated successfully, but these errors were encountered: