Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Thermal Sharpening #4

Closed
qjhart opened this issue Nov 4, 2015 · 1 comment
Closed

Thermal Sharpening #4

qjhart opened this issue Nov 4, 2015 · 1 comment
Assignees

Comments

@qjhart
Copy link
Member

qjhart commented Nov 4, 2015

We need a methodology for our thermal sharpening algorithm. The problem with the methodology of the METRIC based sharpening is that it's based only on NDVI. The way that they partition the bias from the T, based on the inverted NDVI. This may be problematic in the Delta.

In addition, the METRIC version uses hot-cold pixels. We have to figure out if we are doing that or not.

@qjhart
Copy link
Member Author

qjhart commented Dec 9, 2015

Merged with #5

@qjhart qjhart closed this as completed Dec 9, 2015
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment