You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
My Bulb does not change to the right color and teprature when i disconect it from the power grid. Logs:
normal startup, when the light bulb is not connected to the power grip
time="2024/07/02 23:37:12" level=info msg="💡 Light Kugel - Activating schedule for Feb 7 2024 (Sunrise: 08:29, Sunset: 16:51)"
time="2024/07/02 23:37:12" level=info msg="💡 Light Kugel - Activating interval 23:31 - 23:59"
time="2024/07/02 23:37:13" level=info msg="💡 Light Kugel - Light just appeared."
time="2024/07/02 23:37:13" level=info msg="💡 Light Kugel - Initializing state to 2000K at 100% brightness."
time="2024/07/02 23:37:30" level=info msg="💡 Light Kugel - Light is no longer reachable. Clearing state..."
now i plug i the bulb
time="2024/07/02 23:38:05" level=info msg="💡 Light Kugel - Light just appeared."
time="2024/07/02 23:38:05" level=info msg="💡 Light Kugel - Initializing state to 2000K at 100% brightness."
time="2024/07/02 23:38:16" level=info msg="💡 Light Kugel - Light state has been changed manually. Disabling Kelvin..."
And it does not work because of the last row in the console output.
It is a normal new e14 philips hue light and a new bridge with the newest software version. when i restart the light with my philips hue smart button or via app everything works fine, but as soon as i remove it from the power grid nothing works.
I have tried all different startup options you can choose in the philips hue app, what behaivior they should have when reconedted to the power grid.
Please give me any tipps or advice :)) thanks a lot!!
The text was updated successfully, but these errors were encountered:
My Bulb does not change to the right color and teprature when i disconect it from the power grid. Logs:
normal startup, when the light bulb is not connected to the power grip
now i plug i the bulb
And it does not work because of the last row in the console output.
It is a normal new e14 philips hue light and a new bridge with the newest software version. when i restart the light with my philips hue smart button or via app everything works fine, but as soon as i remove it from the power grid nothing works.
I have tried all different startup options you can choose in the philips hue app, what behaivior they should have when reconedted to the power grid.
Please give me any tipps or advice :)) thanks a lot!!