modbus-rtu: don't use O_EXCL when opening the device #760

Open
wants to merge 1 commit into
base: master
Choose a base branch
from

Conversation

mhei
Copy link
Contributor

@mhei mhei commented Jul 27, 2024

Quote from 'man 2 open':
-snip-
...
In general, the behavior of O_EXCL is undefined if it is used without O_CREAT. ...
-snap-

Since we don't create the device file here - we just want to open (hopefully) existing ones - let's simply drop this flag to be on the safe side.

@cla-bot cla-bot bot added the cla-signed label Jul 27, 2024
Quote from 'man 2 open':
-snip-
...
In general, the behavior of O_EXCL is undefined if it is used without O_CREAT.
...
-snap-

Since we don't create the device file here - we just want to open
(hopefully) existing ones - let's simply drop this flag to be on
the safe side.

Signed-off-by: Michael Heimpold <[email protected]>