diff --git a/json/model_701.json b/json/model_701.json index 869c048..d406000 100644 --- a/json/model_701.json +++ b/json/model_701.json @@ -39,19 +39,19 @@ "label": "Single Phase", "name": "SINGLE_PHASE", "notes": "", - "value": 1 + "value": 0 }, { "label": "Split Phase", "name": "SPLIT_PHASE", "notes": "", - "value": 2 + "value": 1 }, { "label": "Three Phase", "name": "THREE_PHASE", "notes": "", - "value": 3 + "value": 2 } ], "type": "enum16" @@ -69,13 +69,13 @@ "label": "Off", "name": "OFF", "notes": "", - "value": 1 + "value": 0 }, { "label": "On", "name": "ON", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" @@ -92,42 +92,42 @@ { "name": "OFF", "notes": "", - "value": 1 + "value": 0 }, { "name": "SLEEPING", "notes": "", - "value": 2 + "value": 1 }, { "name": "STARTING", "notes": "", - "value": 3 + "value": 2 }, { "name": "MPPT", "notes": "", - "value": 4 + "value": 3 }, { "name": "THROTTLED", "notes": "", - "value": 5 + "value": 4 }, { "name": "SHUTTING_DOWN", "notes": "", - "value": 6 + "value": 5 }, { "name": "FAULT", "notes": "", - "value": 7 + "value": 6 }, { "name": "STANDBY", "notes": "", - "value": 8 + "value": 7 } ], "type": "enum16" @@ -146,14 +146,14 @@ "label": "Disconnected", "name": "DISCONNECTED", "notes": "", - "value": 1 + "value": 0 }, { "desc": "Connected to the grid.", "label": "Connected", "name": "CONNECTED", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" diff --git a/json/model_702.json b/json/model_702.json index 8a3f68e..15d5a96 100644 --- a/json/model_702.json +++ b/json/model_702.json @@ -204,12 +204,12 @@ { "name": "CAT_A", "notes": "", - "value": 1 + "value": 0 }, { "name": "CAT_B", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" @@ -223,17 +223,17 @@ { "name": "CAT_1", "notes": "", - "value": 1 + "value": 0 }, { "name": "CAT_2", "notes": "", - "value": 2 + "value": 1 }, { "name": "CAT_3", "notes": "", - "value": 3 + "value": 2 } ], "type": "enum16" diff --git a/json/model_704.json b/json/model_704.json index 3528e01..48e57e9 100644 --- a/json/model_704.json +++ b/json/model_704.json @@ -461,14 +461,14 @@ "label": "Active Power As Max Percent", "name": "W_MAX_PCT", "notes": "", - "value": 1 + "value": 0 }, { "desc": "Active power setting is in watts.", "label": "Active Power As Watts", "name": "WATTS", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" @@ -593,28 +593,28 @@ "label": "Reactive Power As Watt Max Pct", "name": "W_MAX_PCT", "notes": "", - "value": 1 + "value": 0 }, { "desc": "Reactive power setting is percent of maximum reactive power.", "label": "Reactive Power As Var Max Pct", "name": "VAR_MAX_PCT", "notes": "", - "value": 2 + "value": 1 }, { "desc": "Reactive power setting is percent of available reactive power.", "label": "Reactive Power As Var Avail Pct", "name": "VAR_AVAIL_PCT", "notes": "", - "value": 3 + "value": 2 }, { "desc": "Reactive power is in vars.", "label": "Reactive Power As Vars", "name": "VARS", "notes": "", - "value": 4 + "value": 3 } ], "type": "enum16" @@ -631,35 +631,35 @@ "label": "Active Power Priority", "name": "ACTIVE", "notes": "", - "value": 1 + "value": 0 }, { "desc": "Reactive power priority.", "label": "Reactive Power Priority", "name": "REACTIVE", "notes": "", - "value": 2 + "value": 1 }, { "desc": "IEEE 1547-2018 power priority mode.", "label": "IEEE 1547 Power Priority", "name": "IEEE_1547", "notes": "", - "value": 3 + "value": 2 }, { "desc": "Track PF setting derived from current active and reactive power settings.", "label": "PF Power Priority", "name": "PF", "notes": "", - "value": 4 + "value": 3 }, { "desc": "Power priority is vendor specific mode.", "label": "Vendor Power Priority", "name": "VENDOR", "notes": "", - "value": 5 + "value": 4 } ], "type": "enum16" @@ -769,14 +769,14 @@ "label": "Max Current Ramp", "name": "A_MAX", "notes": "", - "value": 1 + "value": 0 }, { "desc": "Ramp based on percent of max active power per second.", "label": "Max Active Power Ramp", "name": "W_MAX", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" diff --git a/json/model_705.json b/json/model_705.json index e25c0bb..cab8a34 100644 --- a/json/model_705.json +++ b/json/model_705.json @@ -68,25 +68,25 @@ "label": "Percent Max Watts", "name": "W_MAX_PCT", "notes": "", - "value": 1 + "value": 0 }, { "label": "Percent Max Vars", "name": "VAR_MAX_PCT", "notes": "", - "value": 2 + "value": 1 }, { "label": "Percent Available Vars", "name": "VAR_AVAL_PCT", "notes": "", - "value": 3 + "value": 2 }, { "label": "Percent Max Apparent Power", "name": "VA_MAX_PCT", "notes": "", - "value": 4 + "value": 3 } ], "type": "enum16" @@ -101,35 +101,35 @@ "label": "Active Power Priority", "name": "ACTIVE", "notes": "", - "value": 1 + "value": 0 }, { "desc": "Reactive power priority.", "label": "Reactive Power Priority", "name": "REACTIVE", "notes": "", - "value": 2 + "value": 1 }, { "desc": "IEEE 1547-2018 power priority mode.", "label": "IEEE 1547 Power Priority", "name": "IEEE_1547", "notes": "", - "value": 3 + "value": 2 }, { "desc": "Track PF setting derived from current active and reactive power settings.", "label": "PF Power Priority", "name": "PF", "notes": "", - "value": 4 + "value": 3 }, { "desc": "Power priority is vendor specific mode.", "label": "Vendor Power Priority", "name": "VENDOR", "notes": "", - "value": 5 + "value": 4 } ], "type": "enum16" diff --git a/json/model_706.json b/json/model_706.json index 86d3f67..da58c4f 100644 --- a/json/model_706.json +++ b/json/model_706.json @@ -67,12 +67,12 @@ { "name": "W_MAX_PCT", "notes": "", - "value": 1 + "value": 0 }, { "name": "W_AVAL_PCT", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" diff --git a/json/model_712.json b/json/model_712.json index 399bacc..cbd453e 100644 --- a/json/model_712.json +++ b/json/model_712.json @@ -68,25 +68,25 @@ "label": "Percent Max Watts", "name": "W_MAX_PCT", "notes": "", - "value": 1 + "value": 0 }, { "label": "Percent Max Vars", "name": "VAR_MAX_PCT", "notes": "", - "value": 2 + "value": 1 }, { "label": "Percent Available Vars", "name": "VAR_AVAL_PCT", "notes": "", - "value": 3 + "value": 2 }, { "label": "Percent Max Apparent Power", "name": "VA_MAX_PCT", "notes": "", - "value": 4 + "value": 3 } ], "type": "enum16" @@ -99,12 +99,12 @@ { "name": "ACTIVE", "notes": "", - "value": 1 + "value": 0 }, { "name": "REACTIVE", "notes": "", - "value": 2 + "value": 1 } ], "type": "enum16" diff --git a/json/model_713.json b/json/model_713.json index 06adb73..65750c9 100644 --- a/json/model_713.json +++ b/json/model_713.json @@ -57,19 +57,19 @@ "desc": "No warnings or errors pending.", "label": "OK", "name": "OK", - "value": 1 + "value": 0 }, { "desc": "One or more warnings pending.", "label": "Warning", "name": "WARNING", - "value": 2 + "value": 1 }, { "desc": "One or more errors pending.", "label": "Error", "name": "ERROR", - "value": 3 + "value": 2 } ], "type": "enum16" diff --git a/json/model_714.json b/json/model_714.json index 9e9b3cc..79dbe6d 100644 --- a/json/model_714.json +++ b/json/model_714.json @@ -20,43 +20,43 @@ "label": "Photovoltaic", "name": "PV", "notes": "", - "value": 1 + "value": 0 }, { "label": "Energy Storage System", "name": "ESS", "notes": "", - "value": 2 + "value": 1 }, { "label": "Electric Vehicle", "name": "EV", "notes": "", - "value": 3 + "value": 2 }, { "label": "Generic Injecting", "name": "INJ", "notes": "", - "value": 4 + "value": 3 }, { "label": "Generic Absorbing", "name": "ABS", "notes": "", - "value": 5 + "value": 4 }, { "label": "Generic Bidirectional", "name": "BIDIR", "notes": "", - "value": 6 + "value": 5 }, { "label": "DC to DC", "name": "DC_DC", "notes": "", - "value": 7 + "value": 6 } ], "type": "enum16" @@ -133,25 +133,25 @@ "label": "Off", "name": "OFF", "notes": "", - "value": 1 + "value": 0 }, { "label": "On", "name": "ON", "notes": "", - "value": 2 + "value": 1 }, { "label": "Warning", "name": "WARNING", "notes": "", - "value": 3 + "value": 2 }, { "label": "Error", "name": "ERROR", "notes": "", - "value": 4 + "value": 3 } ], "type": "enum16" @@ -174,12 +174,6 @@ "notes": "", "value": 1 }, - { - "label": "Reserved", - "name": "RESERVED", - "notes": "", - "value": 19 - }, { "label": "DC Disconnect", "name": "DC_DISCONNECT", @@ -228,6 +222,12 @@ "notes": "", "value": 15 }, + { + "label": "Reserved", + "name": "RESERVED", + "notes": "", + "value": 19 + }, { "label": "Test Failed", "name": "TEST_FAILED", diff --git a/json/model_715.json b/json/model_715.json index a56b4f3..776061f 100644 --- a/json/model_715.json +++ b/json/model_715.json @@ -71,22 +71,22 @@ { "label": "Stop the DER", "name": "STOP", - "value": 1 + "value": 0 }, { "label": "Start the DER", "name": "START", - "value": 2 + "value": 1 }, { "label": "Enter Standby Mode", "name": "ENTER_STANDBY", - "value": 3 + "value": 2 }, { "label": "Exit Standby Mode", "name": "EXIT_STANDBY", - "value": 4 + "value": 3 } ], "type": "enum16"