space status not set after boot #2

Open
lx1ge opened this issue Jan 16, 2020 · 1 comment
Open

space status not set after boot #2

lx1ge opened this issue Jan 16, 2020 · 1 comment

Comments

@lx1ge
Copy link
Contributor

lx1ge commented Jan 16, 2020

despite the rule in level2.ruies

rule "Startup"
when
    System started
then
  if (entrance_door_status.state.toString == 'OFF') {
      SpaceStatus = 'open'
  } else { 
      SpaceStatus = 'closed'
  }
end

the space status is set to closed when the rasperry boots, even if the door is actually open

@lx1ge lx1ge changed the title space status after boot not set space status not set after boot Jan 16, 2020
@Gunstick
Copy link
Collaborator

I added some debug log: the state is read as NULL instead of ON or OFF. Probably an initialization timing issue.