Notifications
You must be signed in to change notification settings - Fork 293
TInyGv8g BeagleBone Black Test Rig Operation
Alden Hart edited this page Aug 17, 2014
·
1 revision
These must be done before operating the tester Make sure the programmer is properly set up. See Programmer Setup
- Connect power to TinyG board. *** BE SURE TO OBSERVE CORRECT POLARITY ***
- +24v line (yellow) is next to corner of board and board mounting hole
- Ground (black) is next to capacitor
- Place jumper on left position of J12 - labeled +12v
- Connect PDI programming header to J10. Red wire should be on the side with the white dot
Make sure the tester is properly set up. See Tester Setup
- Turn off the 24 volt power from the switch if not already off
- Plug in the 5volt power supply for the BeagleBone Black.
- This connects to the barrel connector on BeagleBone on the the left-side front of the tester.
- Wait at least 30 seconds for the BBB to boot
- Confirm that the short USB connector connects from the A connector on the BBB to the B connector on the tester board.
- Turn off board power using switch on tester.
- Blue power LED on tester (next to power input terminal) should fade off, indicating it is safe to remove any test board if there is one already on the tester.
- Do not unplug or turn off BeagleBone 5v power wall unit.
- Carefully align TinyG to test on threaded standoffs. Make sure all pogo pins make contact.
- Loosely screw on the 4 threaded standoffs to hold the board down. Do not tighten (or you may have problems on removal).
Checklist. Perform in order.
- Turn power switch off first
- Unplug 5v wall power supply
- Place Beaglebone Black on mounting headers with Ethernet jack in cutaway
- Connect BBB USB host (A connector) to USB B connector on tester board (NOT on Tiny board)
Getting Started Pages
- Home
- What is TinyG?
- Getting Started
- Connecting TinyG
- Configuring TinyG
- Sending Gcode Files
- Flashing TinyG
- Chilipeppr
Reference Pages
- TinyG Help Page
- TinyG Tuning
- TinyG Command Line
- TinyG JSON
- Gcode Support
- Homing and Limits
- Inch and MM Units
- Alarms and Exceptions
- Coordinate Systems
- Status Codes
- Status Reports
- Power Management
- Feedhold and Resume
- Licensing
- TinyG v8 Data Sheet
Discussion Topics
- Test-Drive-TinyG
- Jerk Controlled Motion
- Gcode Parsing
- Shapeoko Setup
- OX CNC TinyG Guide
- Creating Gcode Files
- Milling With Noisy Spindles
- Stepper Motors and Power Supplies
- Text Wrappers and Transaction IDs
- Using External Drivers
- TinyG Projects
Chilipeppr
- Chilipeppr
- Chilipeppr Advanced Usage
- Chilipeppr Archive and Restore Parameters
- ChiliPeppr PCB Auto Level
- Automatic Z Homing When Milling PCBs
Troubleshooting
Developer Pages