title | description | addedAt | pageClass |
---|---|---|---|
Philips 324131092621 control via MQTT |
Integrate your Philips 324131092621 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2019-07-22 20:08:17 UTC |
device-page |
Model | 324131092621 |
Vendor | Philips |
Description | Hue dimmer switch |
Exposes | battery, action, action_duration, linkquality |
Picture |
Factory reset the Hue dimmer switch by pressing and holding the setup button on the back for 10 seconds.
Restart the Hue dimmer switch by holding all 4 buttons of the Hue dimmer switch. You can let go when the light on the front flashes red/green briefly.
Many devices can be factory reset / re-paired with a help of Hue dimmer switch:
- Make sure your device is powered on.
- Take the dimmer and hold the ON and OFF buttons close to your device for approximately 10 seconds.
- After about 10 seconds both your Zigbee device and the Hue dimmer should flash.
- Hold it down for a further one second.
- Your device should now be discoverable by your network.
To use the Hue dimmer switch to factory reset a Hue light bulb see HOWTO: Factory reset a Hue bulb.
This method also works for Philips Hue Lightstrips, IKEA Trådfri, Sonoff ZBMINI, and Tuya light bulbs.
If you want to bind the dimmer to a (Hue) lamp you'll have to bind it to the lamp through MQTT and unbind it from the coordinator. Use the dimmer as source and a literal coordinator
as target for that.
- Method 1: Press all four buttons for 4 seconds. When the light turns green, release the buttons. The device will flash green and red alternatively after which it will reconnect to the network.
- Method 2: Use a needle or paperclip to press the reset button on the back for 10 seconds. The behavior is similar to method 1
If actions (e.g. applying zigbee2mqtt/bridge/request/device/remove to a dimmer) result in timeouts, perform a reset (see above) and apply the action right after the device announced itself in the network.
The dimmer appears to be working normally and the logs in Zigbee2MQTT look good. However, nothing happens when a button is pressed (no light, no log message in Zigbee2MQTT). In this case:
- Reset the device
- Use zigbee2mqtt/bridge/request/device/remove to remove the device from the network (this should result in a "left the network" log message)
- Allow joining of new devices in Zigbee2MQTT
- Reset the device again
- Wait for it to pair again. The device should now be operational.
This device supports OTA updates, for more information see OTA updates.
How to use device type specific configuration
-
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
-
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Only works when legacy is false. Example:
simulated_brightness:
delta: 20 # delta per interval, default = 20
interval: 200 # interval in milliseconds, default = 200
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It's not possible to read (/get
) or write (/set
) this value.
The possible values are: on_press
, on_press_release
, on_hold
, on_hold_release
, up_press
, up_press_release
, up_hold
, up_hold_release
, down_press
, down_press_release
, down_hold
, down_hold_release
, off_press
, off_press_release
, off_hold
, off_hold_release
.
Value can be found in the published state on the action_duration
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is s
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.