From 1db94a199d968372a293233f92423368f8cb3240 Mon Sep 17 00:00:00 2001 From: Norbert Richter Date: Sun, 12 Nov 2023 09:47:31 +0100 Subject: [PATCH] Update NeoPool commands --- docs/Commands.md | 2 ++ docs/NeoPool.md | 73 ++++-------------------------------------------- 2 files changed, 7 insertions(+), 68 deletions(-) diff --git a/docs/Commands.md b/docs/Commands.md index 17e0017ea7..3d43246a2e 100644 --- a/docs/Commands.md +++ b/docs/Commands.md @@ -978,6 +978,7 @@ Command|Parameters NPFiltration|`{ {}}`
get/set manual filtration (state = `0` or `1`, speed = `1..3`). Get if state is omitted, otherwise set accordingly ``:
  • `0` - manual turn filtration pump off
  • `1` - manual turn filtration pump on
optional speed control is possible for non-standard filtration types:
  • `1` - slow
  • `2` - medium
  • `3` - fast
NPFiltrationmode|`{}`
get/set filtration mode (mode = `0..4` or `13`). Get if mode is omitted, otherwise set accordingly ``:
  • `0` - *MANUAL*
    allows to turn the filtration (and all other systems that depend on it) on and off
  • `1` - *AUTO*
    allows filtering to be turned on and off according to the settings of the *MBF_PAR_TIMER_BLOCK_FILT_INT* timers.
  • `2` - *HEATING*
    similar to the AUTO mode, but includes setting the temperature for the heating function. This mode is activated only if the BF_PAR_HEATING_MODE register is at 1 and there is a heating relay assigned.
  • `3` - *SMART*
    adjusts the pump operating times depending on the temperature. This mode is activated only if the MBF_PAR_TEMPERATURE_ACTIVE register is at 1.
  • `4` - *INTELLIGENT*
    performs an intelligent filtration process in combination with the heating function. This mode is activated only if the MBF_PAR_HEATING_MODE register is at 1 and there is a heating relay assigned.
  • `13` - *BACKWASH*
    started when the backwash operation is activated.
NPFiltrationspeed|`{}`
(only available for non-standard filtration types)
get/set manual filtration speed (speed = `1..3`)
get filtration speed if `` is omitted, otherwise set new ``:
  • `1` - Low
  • `2` - Mid
  • `3` - High
+NPBoost|`{}`
get/set hydrolysis/electrolysis boost mode (mode = `0..2` or `OFF`, `ON`, `REDOX`)
get if mode is omitted, otherwise set accordingly ``:
  • `0` or `OFF` - *Boost off*
    disables the boost mode
  • `1` or `ON` - *Boost on*
    enables the boost mode independent of the redox value
  • `2` or `REDOX` - *Boost on with Redox control*
    similar to ON, but with consideration of the current redox settings.
Please note that the boost function also always switches the filtration to on. NPTime|`{