Is your feature request related to a problem? Please describe.
I am extending the number of panels of my installation using the garage roof. With the extension I am going beyond the maximum number of allowed (Hoymiles) ten inverters. I would need to have 11 :-(
Describe the solution you'd like
Any chance to get the maximum number of inverters increased in the standard "opendtu-generic.bin" (at least to 14).
Describe alternatives you've considered
Thanks to a running discussion in German I am aware of adjusting the file:
OpenDTU/include/Configuration.h
old: #define INV_MAX_COUNT 10
new: #define INV_MAX_COUNT 14
It is mentioned that more is not possible because of the config size.
The other alternative of adding additional OpenDTUs would be possible but if there is a way around I would appreciate it. The integration into Home Assistant would be simpler staying with one piece of hardware
Additional context
No response
The text was updated successfully, but these errors were encountered:
It is limited to 10 because of the available memory in the ESP32.
But you are free to test it with 14. I will not increase the value because of possible stability issues.
This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new discussion or issue for related concerns.
Is your feature request related to a problem? Please describe.
I am extending the number of panels of my installation using the garage roof. With the extension I am going beyond the maximum number of allowed (Hoymiles) ten inverters. I would need to have 11 :-(
Describe the solution you'd like
Any chance to get the maximum number of inverters increased in the standard "opendtu-generic.bin" (at least to 14).
Describe alternatives you've considered
Thanks to a running discussion in German I am aware of adjusting the file:
OpenDTU/include/Configuration.h
old: #define INV_MAX_COUNT 10
new: #define INV_MAX_COUNT 14
It is mentioned that more is not possible because of the config size.
The other alternative of adding additional OpenDTUs would be possible but if there is a way around I would appreciate it. The integration into Home Assistant would be simpler staying with one piece of hardware