Notifications
You must be signed in to change notification settings - Fork 3
/
unit1.pas
220 lines (193 loc) · 6.1 KB
/
unit1.pas
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
unit Unit1;
{$mode objfpc}{$H+}
interface
uses
Classes, SysUtils, FileUtil, Forms, Controls, Graphics, Dialogs, StdCtrls,
ComCtrls, Unix, BaseUnix;
type
{ TForm1 }
TForm1 = class(TForm)
pathset: TButton;
setbox: TCheckBox;
pathbox: TEdit;
pathGroup: TGroupBox;
quit: TButton;
apply: TButton;
driftBar: TTrackBar;
driftGroup: TGroupBox;
speedGroup: TGroupBox;
senseGroup: TGroupBox;
speedBar: TTrackBar;
senseBar: TTrackBar;
procedure applyClick(Sender: TObject);
procedure FormCreate(Sender: TObject);
procedure pathsetClick(Sender: TObject);
procedure quitClick(Sender: TObject);
private
{ private declarations }
public
{ public declarations }
end;
const
conpath = '/etc/tmpfiles.d/tpconfig.conf';
devpath1 = '/sys/devices/platform/i8042/serio1/serio2/'; //hardcoded paths to devices
devpath2 = '/sys/devices/platform/i8042/serio1/'; //TODO: make less arse
var
Form1: TForm1;
confH: textfile;
confile: string;
tp: boolean;
workingpath: string;
sysfile: text;
sensitivityt: string;
speedt: string;
driftt: string;
sett: string;
sensitivity: byte;
speed: byte;
drift: byte;
setnum: byte;
setstr: string;
tempfile: text;
user: LongWord;
messagereturn: longint;
assembledStr: string;
checkStr: string;
implementation
{$R *.lfm}
{ TForm1 }
procedure TForm1.FormCreate(Sender: TObject);
begin
fpsystem('touch '+conpath);
tp := false;
if FileExists(devpath1+'sensitivity') then
begin
tp := true;
workingpath := devpath1;
pathbox.Text := workingpath;
end;
if FileExists(devpath2+'sensitivity') then
begin
tp := true;
workingpath := devpath2;
pathbox.Text := workingpath;
end;
if not tp then
begin
messagereturn := Application.MessageBox('No TrackPoint found at the default path, you must specify one.', 'Error');
apply.Enabled := false;
pathbox.Enabled := true;
pathset.Enabled := true;
end;
if FileExists(conpath) then
begin
user := fpgeteuid;
if not (user=0) then
begin
messagereturn := Application.MessageBox('ERROR: Must be run as root!', 'Fatal Error');
halt;
end;
if FileExists(workingpath+'sensitivity') then
begin
{check current sensitivity}
AssignFile(sysfile, workingpath+'sensitivity');
reset(sysfile);
readln(sysfile, sensitivityt);
val(sensitivityt, sensitivity);
senseBar.Position := sensitivity; {initialises the slider with current setting}
{check current speed}
AssignFile(sysfile, workingpath+'speed');
reset(sysfile);
readln(sysfile, speedt);
val(speedt, speed);
speedBar.Position := speed; {ditto above}
{check current drift time}
AssignFile(sysfile, workingpath+'drift_time');
reset(sysfile);
readln(sysfile, driftt);
val(driftt, drift);
driftBar.Position := drift; {ditto above}
{check current "press to select" setting}
AssignFile(sysfile, workingpath+'press_to_select');
reset(sysfile);
readln(sysfile, sett);
val(sett, setnum);
if not setnum = 0 then
begin
setbox.Checked := true; {ditto above, just substitute box for slider}
end;
end;
end;
end;
procedure TForm1.pathsetClick(Sender: TObject);
begin
checkStr := pathbox.Text;
if FileExists(checkStr+'sensitivity') then
begin
workingpath := checkStr;
apply.Enabled := true;
{check current sensitivity}
AssignFile(sysfile, workingpath+'sensitivity');
reset(sysfile);
readln(sysfile, sensitivityt);
val(sensitivityt, sensitivity);
senseBar.Position := sensitivity; {initialises the slider with current setting}
{check current speed}
AssignFile(sysfile, workingpath+'speed');
reset(sysfile);
readln(sysfile, speedt);
val(speedt, speed);
speedBar.Position := speed; {ditto above}
{check current drift time}
AssignFile(sysfile, workingpath+'drift_time');
reset(sysfile);
readln(sysfile, driftt);
val(driftt, drift);
driftBar.Position := drift; {ditto above}
{check current "press to select" setting}
AssignFile(sysfile, workingpath+'press_to_select');
reset(sysfile);
readln(sysfile, sett);
val(sett, setnum);
if not setnum = 0 then
begin
setbox.Checked := true; {ditto above, just substitute box for slider}
end; //I'm well aware that having two of these check blocks is redundant
messagereturn := Application.MessageBox('TrackPoint found at path.', 'Success');
end;
if not FileExists(workingpath+'sensitivity') then
messagereturn := Application.MessageBox('No TrackPoint found at path.', 'Error');
end; //I'm just too lazy to put them in a procedure when I can ctrl+c ctrl+v
procedure TForm1.applyClick(Sender: TObject);
begin
//copies the value on the sliders into bytes for IntToStr later.
sensitivity := senseBar.Position;
speed := speedBar.Position;
drift := driftBar.Position;
setstr := '0';
if setbox.Checked then
setstr := '1';
AssignFile(confH, conpath);
rewrite(confH);
{puts together the lines of the SystemD script which sets the sensitivity
on boot}
assembledStr := 'w '+workingpath+'sensitivity - - - - '+IntToStr(sensitivity);
writeln(confH, assembledStr);
//ditto above but for speed.
assembledStr := 'w '+workingpath+'speed - - - - '+IntToStr(speed);
writeln(confH, assembledStr);
//drift this time
assembledStr := 'w '+workingpath+'drift_time - - - - '+IntToStr(drift);
writeln(confH, assembledStr);
//now for press to select
assembledStr := 'w '+workingpath+'press_to_select - - - - '+setstr;
writeln(confH, assembledStr);
CloseFile(confH); //closes the script, writing the contents to the disk
fpsystem('systemd-tmpfiles --prefix=/sys --create'); {tells systemD to run the script}
end;
procedure TForm1.quitClick(Sender: TObject);
begin
{$I-}
halt;
end;
end.