This is most certainly an upstream issue but we might be able to include a workaround in Pyra.
What happened: October 2nd in the morning the system was set to measure but CamTracker was drifting until it was restarted at 09.45. The azimuth was above 200° (not sure what exact value) but at least as high so that the PLC closed the cover. Nevertheless, CamTracker reported a low az-offset and elev-offset in the logs and the absolute values also seemed correct.
Next steps: Investigate the logs in more detail to see what CamTracker was doing and how to possible detect this malfunction using the logs.