Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsmartRead.sh
executable file
·116 lines (90 loc) · 3.97 KB
/
smartRead.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
#!/bin/bash
# Copyright (c) 2020 Manuel Pitz
#
# Licensed under the Apache License, Version 2.0, <LICENSE-APACHE or
# http://apache.org/licenses/LICENSE-2.0> or the MIT license <LICENSE-MIT or
# http://opensource.org/licenses/MIT>, at your option. This file may not be
# copied, modified, or distributed except according to those terms.
DEBUG=0
handle_Type () {
local vendor=$1
local attrName=$2
local data=$3[@]
temp=`grep "$attrName" <<< "$data" | sed "s/^[ \t]*//" | tr -s ' ' | cut -d" " -f10 | sed "s/^[ \t]*//"`
echo $temp
}
handle_singleCol () {
local vendor=$1
local attrName=$2
local data=$3[@]
temp=`grep "$attrName" <<< "$data" | sed "s/^[ \t]*//" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
echo $temp
}
handle_SATA_HDD () {
local vendor=$1
local driveData=$2[@]
temp=$(handle_Type $vendor "Temperature_Celsius" "$driveData")
seek_err=$(handle_Type $vendor "Seek_Error_Rate" "$driveData")
read_err=$(handle_Type $vendor "Raw_Read_Error_Rate" "$driveData")
power_on=$(handle_Type $vendor "Power_On_Hours" "$driveData")
status=$(handle_singleCol $vendor "SMART overall-health self-assessment test result:" "$driveData")
printf "%10s %10s %20s %20s %10s %10s %10s %10s %10s\n" $path "$vendor" "$driveModel" "$driveSerial" "$temp" "$seek_err" "$read_err" "$power_on" "$status"
}
handle_SAS_HDD () {
local vendor=$1
local driveData=$2[@]
if [ $DEBUG == 1 ]; then
echo "SAS handle"
fi
temp=`grep "Drive Temperature:" <<< "$driveData" | tr -s ' ' | cut -d" " -f4 | sed "s/^[ \t]*//"`
readCorrected=`grep "read:" <<< "$driveData" | tr -s ' ' | cut -d" " -f5 | sed "s/^[ \t]*//"`
readunCorrected=`grep "read:" <<< "$driveData" | tr -s ' ' | cut -d" " -f8 | sed "s/^[ \t]*//"`
writeCorrected=`grep "write:" <<< "$driveData" | tr -s ' ' | cut -d" " -f5 | sed "s/^[ \t]*//"`
writeunCorrected=`grep "write:" <<< "$driveData" | tr -s ' ' | cut -d" " -f8 | sed "s/^[ \t]*//"`
seek_err=$(handle_Type $vendor "Seek_Error_Rate" "$driveData")
read_err=$(($readCorrected + $readunCorrected + $writeCorrected + $writeunCorrected))
power_on=$(handle_Type $vendor "Power_On_Hours" "$driveData")
status=$(handle_singleCol $vendor "Status:" "$driveData")
printf "%10s %10s %20s %20s %10s %10s %10s %10s %10s\n" $path "$vendor" "$driveModel" "$driveSerial" "$temp" "$seek_err" "$read_err" "$power_on" "$status"
}
echo "readSmartData"
mapfile -t DRIVES < <(smartctl --scan)
printf "%10s %10s %20s %20s %10s %10s %10s %10s %10s\n" "Path" "Vendor" "Model" "Serial" "Temp" "Seek_err" "Read_err" "Power_on" "Status"
for drive in "${DRIVES[@]}"
do
path=`cut -d" " -f1 <<< "$drive"`
devType=`cut -d" " -f6 <<< "$drive"`
driveData=`smartctl -a $path`
driveFamily=`grep "Model Family:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
driveVendor=`grep "Vendor:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
driveModel=`grep "Device Model:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
driveSerial=`grep "Serial Number:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
if [ -z "$driveSerial" ]; then
driveSerial=`grep "Serial number:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
fi
if [ -z "$driveModel" ]; then
driveModel=`grep "Product:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
fi
#echo $driveName
if [ -n "$driveVendor" ]; then
vendor=$driveVendor
elif [ -z "$driveFamily" ]; then
vendor=`cut -d" " -f1 <<< "$driveModel"`
else
vendor=`cut -d" " -f1 <<< "$driveFamily"`
fi
tmpModel=`cut -d" " -f2 <<< "$driveModel"`
if [ -n "$tmpModel" ]; then
driveModel=$tmpModel
fi
if [[ $vendor == *"Seagate"* ]]; then
#echo "rerun smartctl for Seagate drives"
driveData=`smartctl -a -v 7,raw48:54 -v 1,raw48:54 $path`
fi
sasFlag=`grep "Transport protocol:" <<< "$driveData" | tr -s ' ' | cut -d":" -f2 | sed "s/^[ \t]*//"`
if [[ $sasFlag == *"SAS"* ]]; then
handle_SAS_HDD $vendor "$driveData"
else
handle_SATA_HDD $vendor "$driveData"
fi
done