77from zigpy .quirks import CustomCluster
88from zigpy .zcl import foundation
99from zigpy .zcl .clusters .closures import WindowCovering
10- from zigpy .zcl .clusters .general import Basic
10+ from zigpy .zcl .clusters .general import Basic , OnOff
11+ from zigpy .zcl .clusters .lighting import Ballast
1112from zigpy .zcl .foundation import BaseAttributeDefs , ZCLAttributeDef
1213
1314SE_MANUF_NAME = "Schneider Electric"
@@ -20,46 +21,157 @@ class SEBasic(CustomCluster, Basic):
2021 class AttributeDefs (Basic .AttributeDefs ):
2122 """Attribute definitions."""
2223
23- se_sw_build_id : Final = ZCLAttributeDef (
24+ # The Application FW Version attribute specifies the firmware version of the application. The format of this
25+ # attribute is XXX.YYY.ZZZ V.
26+ # XXX = major version
27+ # YYY = minor version
28+ # ZZZ = patch version
29+ # V = Build Type (One of the following: D = Development version, T0, T1 = Verification version, V = Validation
30+ # version, R = Official Release version).
31+ se_application_fw_version : Final = ZCLAttributeDef (
2432 id = 0xE001 ,
2533 type = t .CharacterString ,
2634 is_manufacturer_specific = True ,
27- ) # value: "002.004.016 R"
28- unknown_attribute_57346 : Final = ZCLAttributeDef (
35+ )
36+ # The Application HWVersion attribute specifies the hardware version of the application design in format
37+ # AAA.BBB.CCC. Meaning:
38+ # AAA - major version
39+ # BBB - minor version
40+ # CCC - patch version
41+ # If version is 000.000.000, HW version is not available.
42+ se_application_hw_version : Final = ZCLAttributeDef (
2943 id = 0xE002 ,
3044 type = t .CharacterString ,
3145 is_manufacturer_specific = True ,
32- ) # value: "001.000.000"
33- unknown_attribute_57348 : Final = ZCLAttributeDef (
46+ )
47+ # Device serial number. Hexadecimal string of 15 chars length.
48+ se_device_serial_number : Final = ZCLAttributeDef (
3449 id = 0xE004 ,
3550 type = t .CharacterString ,
3651 is_manufacturer_specific = True ,
37- ) # value: "213249FEFF5ECFD"
38- unknown_attribute_57351 : Final = ZCLAttributeDef (
52+ )
53+ # The ProductIdentifier attribute specifies the unique internal numerical identifier of the product. See device
54+ # description for this value.
55+ se_product_identifier : Final = ZCLAttributeDef (
3956 id = 0xE007 ,
4057 type = t .enum16 ,
4158 is_manufacturer_specific = True ,
4259 )
43- se_device_type : Final = ZCLAttributeDef (
60+ # The ProductRange attribute specifies the name of the range to which the product belongs.
61+ se_product_range : Final = ZCLAttributeDef (
4462 id = 0xE008 ,
4563 type = t .CharacterString ,
4664 is_manufacturer_specific = True ,
47- ) # value: "Wiser Light"
48- se_model : Final = ZCLAttributeDef (
65+ )
66+ # The ProductModel attribute specifies the name of the product model. Same value as model identifier attribute
67+ # 0x0005.
68+ se_product_model : Final = ZCLAttributeDef (
4969 id = 0xE009 ,
5070 type = t .CharacterString ,
5171 is_manufacturer_specific = True ,
52- ) # value: "NHPB/SHUTTER/1"
53- se_realm : Final = ZCLAttributeDef (
72+ )
73+ # The ProductFamily attribute specifies the name of the family to which the product belongs.
74+ se_product_family : Final = ZCLAttributeDef (
5475 id = 0xE00A ,
5576 type = t .CharacterString ,
5677 is_manufacturer_specific = True ,
57- ) # value: "Wiser Home"
58- unknown_attribute_57355 : Final = ZCLAttributeDef (
78+ )
79+ # VendorURL, value: "http://www.schneider-electric.com"
80+ se_vendor_url : Final = ZCLAttributeDef (
5981 id = 0xE00B ,
6082 type = t .CharacterString ,
6183 is_manufacturer_specific = True ,
62- ) # value: "http://www.schneider-electric.com"
84+ )
85+
86+
87+ class SEOnTimeReloadOptions (t .bitmap8 ):
88+ """Valid values for the SE OnTimeReloadOptions attr."""
89+
90+ # OnTimeReload timer can be canceled by receiving OFF command -> light is going OFF immediately.
91+ # If this bit is not set, the timer can not be canceled, it is always restarted.
92+ OnTimeReloadCanceledByOffCommand = 0x1
93+
94+ # Impulse mode active. Whenever output should be switched ON, it will be switched ON only for 200msec.
95+ # OnTimeReload attributes is ignored, also bit0 inside this attribute has no sense. If this bit is not set,
96+ # impulse mode is disabled.
97+ ImpulseMode = 0x2
98+
99+
100+ class SEOnOff (CustomCluster , OnOff ):
101+ """Schneider Electric manufacturer specific OnOff cluster."""
102+
103+ class AttributeDefs (OnOff .AttributeDefs ):
104+ """Attribute definitions."""
105+
106+ # Has meaning only if attribute OnTimeReload is not 0. Defines number of seconds before the light is switched
107+ # off automatically when the user is somehow inform the light will be switched off automatically. Value 0 or
108+ # 0xFFFF disables pre-warning. For switch is just short switch OFF and ON, for dimmer device goes to 60
109+ # percent and starts slowly dim down. During this time user can reload the time and postpone automatic switch
110+ # off for time defined in OnTimeReload. If you enter value greater than 6553, after reboot you will read again
111+ # value 6553. If you enter 0xFFFF, functionality will be disabled.
112+ se_pre_warning_time : Final = ZCLAttributeDef (
113+ id = 0xE000 ,
114+ type = t .uint16_t ,
115+ is_manufacturer_specific = True ,
116+ )
117+
118+ # Defines number of seconds before the light is switched off automatically. Time is in seconds.
119+ # Value 0 disable the functionality. When brightness is changed, or ON command is received, timer is always
120+ # restarted. Check OnTimeReloadOptions for possible impulse mode (if attribute is implemented).
121+ se_on_time_reload : Final = ZCLAttributeDef (
122+ id = 0xE001 ,
123+ type = t .uint32_t ,
124+ is_manufacturer_specific = True ,
125+ )
126+
127+ se_on_time_reload_options : Final = ZCLAttributeDef (
128+ id = 0xE002 ,
129+ type = SEOnTimeReloadOptions ,
130+ is_manufacturer_specific = True ,
131+ )
132+
133+
134+ class SEControlMode (t .enum8 ):
135+ """Dimming mode for PUCK/DIMMER/* and NHROTARY/DIMMER/1."""
136+
137+ Auto = 0
138+ RC = 1
139+ RL = 2
140+ RL_LED = 3
141+
142+
143+ class SEWiringMode (t .enum8 ):
144+ """Dimmer wiring mode. Default value depends on how the dimmer is connected to the mains."""
145+
146+ TwoWiredMode = 0
147+ ThreeWiredMode = 1
148+
149+
150+ class SEDimmingCurve (t .enum8 ):
151+ """Dimmer dimming curve."""
152+
153+ Logarithmic = 0
154+ Linear = 1 # Not supported in current FW, but defined in the spec
155+ Exponential = 2 # Not supported in current FW, but defined in the spec
156+
157+
158+ class SEBallast (CustomCluster , Ballast ):
159+ """Schneider Electric Ballast cluster."""
160+
161+ manufacturer_id_override = SE_MANUF_ID
162+
163+ class AttributeDefs (Ballast .AttributeDefs ):
164+ """Attribute definitions."""
165+
166+ se_control_mode : Final = ZCLAttributeDef (
167+ id = 0xE000 , type = SEControlMode , is_manufacturer_specific = True
168+ )
169+ se_wiring_mode : Final = ZCLAttributeDef (
170+ id = 0xE002 , type = t .enum8 , is_manufacturer_specific = True
171+ )
172+ se_dimming_curve : Final = ZCLAttributeDef (
173+ id = 0xE002 , type = t .enum8 , is_manufacturer_specific = True
174+ )
63175
64176
65177class SEWindowCovering (CustomCluster , WindowCovering ):
@@ -138,17 +250,59 @@ async def command(
138250 return await super ().command (command_id , * args , ** kwargs )
139251
140252
141- class SELedIndicatorSignals (t .enum8 ):
253+ class SESwitchIndication (t .enum8 ):
142254 """Available LED indicator signal combinations.
143255
144256 Shutter movement can be indicated with a red LED signal. A green LED
145257 light permanently provides orientation, if desired.
146258 """
147259
148- MOVEMENT_ONLY = 0x00
149- MOVEMENT_AND_ORIENTATION = 0x01
150- ORIENTATION_ONLY = 0x02
151- NONE = 0x03
260+ # For lights: LED is on when load is on. For shutter controllers: red LED is on while shutter is moving.
261+ FollowsLoad = 0x00
262+ # For lights: LED is always on. For shutter controllers: red LED is on while shutter is moving, green LED indicates
263+ # direction.
264+ AlwaysOn = 0x01
265+ # For lights: LED is on when load is off. For shutter controllers: red LED is never on, green LED indicates
266+ # direction.
267+ InverseOfLoad = 0x02
268+ # LED(s) are always off.
269+ AlwaysOff = 0x03
270+
271+
272+ class SESwitchAction (t .enum8 ):
273+ """Valid values for the SE SwitchAction attribute."""
274+
275+ # Behave like a light switch (Up = On, Down = Off)
276+ Light = 0x00
277+ # Behave like an inverted light switch (Up = Off, Down = On)
278+ LightOpposite = 0xFE
279+ # Behave like a dimmer (Up/rotate right = on and/or dim up, Down/rotate left = off and/or dim down)
280+ Dimmer = 0x01
281+ # Behave like an inverted dimmer (Up/rotate right = off and/or dim down, Down/rotate left = on and/or dim up)
282+ DimmerOpposite = 0xFD
283+ # Behave like a standard shutter controller (up/rotate right = move shutter up, down/rotate left = move shutter
284+ # down, short press to stop movement)
285+ StandardShutter = 0x02
286+ # Behave like an inverted standard shutter controller (up/rotate right = move shutter down, down/rotate left = move
287+ # shutter up, short press to stop movement)
288+ StandardShutterOpposite = 0xFC
289+ # Behave like a Schneider shutter controller using SE custom Window Covering cluster (up/rotate right = move
290+ # shutter up, down/rotate left = move shutter down, short press to stop movement)
291+ SchneiderShutter = 0x03
292+ # Behave like an inverted Schneider shutter controller using SE custom Window Covering cluster (up/rotate right =
293+ # move shutter down, down/rotate left = move shutter up, short press to stop movement)
294+ SchneiderShutterOpposite = 0xFB
295+ # Recall scenes according to the Up/DownSceneID attributes, and group using the Up/DownGroupID attributes.
296+ Scene = 0x04
297+ # No observable function?
298+ ToggleLight = 0x05
299+ # No observable function?
300+ ToggleDimmer = 0x06
301+ # No observable function?
302+ AlternateLight = 0x07
303+ # No observable function?
304+ AlternateDimmer = 0x08
305+ NotUsed = 0x7F
152306
153307
154308class SESpecific (CustomCluster ):
@@ -161,37 +315,50 @@ class SESpecific(CustomCluster):
161315 class AttributeDefs (BaseAttributeDefs ):
162316 """Attribute definitions."""
163317
164- led_indicator_signals : Final = ZCLAttributeDef (
318+ se_switch_indication : Final = ZCLAttributeDef (
165319 id = 0x0000 ,
166- type = SELedIndicatorSignals ,
320+ type = SESwitchIndication ,
167321 is_manufacturer_specific = True ,
168322 )
169- unknown_attribute_1 : Final = ZCLAttributeDef (
323+ # Default values depends on endpoint and device type. More info you find in device description.
324+ se_switch_actions : Final = ZCLAttributeDef (
170325 id = 0x0001 ,
171- type = t . enum8 ,
326+ type = SESwitchAction ,
172327 is_manufacturer_specific = True ,
173328 )
174- unknown_attribute_16 : Final = ZCLAttributeDef (
329+ # The UpSceneID attribute represents the Scene Id field value of any Scene command cluster transmitted by the
330+ # device when user activates is rocker up side according to the rocker configuration. See SwitchActions
331+ # attribute.
332+ se_up_scene_id : Final = ZCLAttributeDef (
175333 id = 0x0010 ,
176334 type = t .uint8_t ,
177335 is_manufacturer_specific = True ,
178336 )
179- unknown_attribute_17 : Final = ZCLAttributeDef (
337+ # The UpGroupID attribute represents the Group Id field value of any Scene command cluster transmitted by the
338+ # device when user activates is rocker up side according to the rocker configuration. Value greater than 0xFFF7
339+ # means, no command is sent. See SwitchActions attribute.
340+ se_up_group_id : Final = ZCLAttributeDef (
180341 id = 0x0011 ,
181342 type = t .uint16_t ,
182343 is_manufacturer_specific = True ,
183344 )
184- unknown_attribute_32 : Final = ZCLAttributeDef (
345+ # The DownSceneID attribute represents the Scene Id field value of any Scene command cluster transmitted by the
346+ # device when user activates is rocker down side according to the rocker configuration. See SwitchActions
347+ # attribute.
348+ se_down_scene_id : Final = ZCLAttributeDef (
185349 id = 0x0020 ,
186350 type = t .uint8_t ,
187351 is_manufacturer_specific = True ,
188352 )
189- unknown_attribute_33 : Final = ZCLAttributeDef (
353+ # The DownGroupID attribute represents the Group Id field value of any Scene command cluster transmitted by the
354+ # device when user activates is rocker down side according to the rocker configuration. Value greater than
355+ # 0xFFF7 means, no command is sent. See SwitchActions attribute.
356+ se_down_group_id : Final = ZCLAttributeDef (
190357 id = 0x0021 ,
191358 type = t .uint16_t ,
192359 is_manufacturer_specific = True ,
193360 )
194- unknown_attribute_65533 : Final = ZCLAttributeDef (
361+ se_cluster_revision : Final = ZCLAttributeDef (
195362 id = 0xFFFD ,
196363 type = t .uint16_t ,
197364 is_manufacturer_specific = True ,