Skip to content

collectors OneWireCollector

Rob Smith edited this page Sep 16, 2014 · 9 revisions

OneWireCollector

The OneWireCollector collects data from 1-Wire Filesystem

You can configure which sensors are read in two way:

  • add section [scan] with attributes and aliases, (collector will scan owfs to find attributes)

or

  • add sections with format id:$SENSOR_ID

See also: http://owfs.org/ Author: Tomasz Prus

Dependencies

  • owfs

Options - Generic Options

Setting Default Description Type
byte_unit byte Default numeric output(s) str
enabled False Enable collecting these metrics bool
measure_collector_time False Collect the collector run time in ms bool
metrics_blacklist None Regex to match metrics to block. Mutually exclusive with metrics_whitelist NoneType
metrics_whitelist None Regex to match metrics to transmit. Mutually exclusive with metrics_blacklist NoneType

Example Output

servers.hostname.owfs.28_2F702A010000.p11 999
servers.hostname.owfs.28_A76569020000.t 22.4375

This file was generated from the python source

Please edit the source to make changes

Clone this wiki locally