Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Pass all AquaTROLL variables through to L1 #99

Merged
merged 1 commit into from
Jan 19, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
17 changes: 14 additions & 3 deletions synoptic/data_TEST/L1_metadata/L1_metadata_vars.csv
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
sensor,variable,research_name,sensor_units,final_units,conversion,low_bound,high_bound,description
Datalogger,Volage,voltage,V,V,x * 1,11,13,Battery voltage
Datalogger,Voltage,voltage,V,V,x * 1,11,13,Battery voltage
Sapflow,NA,sapflow_2.5cm,?,?,x * 1,NA,NA,NA
Sapflow,NA,sapflow_5cm,?,?,x * 1,NA,NA,NA
Teros,VWC,soil_vwc_5cm,m3/m3,m3/m3,(3.879*10^-4) * x - 0.6956,0,1,calibration equation for mineral soil VWC
Expand All @@ -14,14 +14,25 @@ Teros,EC,soil_EC_15cm,dS/m,uS/cm,x * 100000,0,20000,NA
Teros,VWC,soil_vwc_30cm,m3/m3,m3/m3,(3.879*10^-4) * x - 0.6956,0,1,calibration equation for mineral soil VWC
Teros,TSOIL,soil_temp_30cm,degC,degC,x * 1,-40,60,NA
Teros,EC,soil_EC_30cm,dS/m,uS/cm,x * 100000,0,20000,NA
AquaTroll,Barometric_Pressure600,gw_bar_pressure,,,x * 1,,,CHECK
AquaTroll,Temperature600,gw_temperature,degC,degC,x * 1,-5,50,Water temperature
AquaTroll,Specific_Conductivity600,gw_conductivity,μS/cm,μS/cm,x * 1,0,350000,Water specific conductivity
AquaTroll,Temperature_Int600,gw_temperature_int,degC,degC,x * 1,-5,50,CHECK
AquaTroll,Actual_Conductivity600,gw_act_cond,μS/cm,μS/cm,x * 1,,,CHECK
AquaTroll,Specific_Conductivity600,gw_spec_cond,μS/cm,μS/cm,x * 1,0,350000,Water specific conductivity
AquaTroll,Salinity600,gw_salinity,PSU,PSU,x * 1,0,350,Water salinity
AquaTroll,TDS600,gw_tds,,,x * 1,,,CHECK
AquaTroll,Water_Density600,gw_density,g/cm3,g/cm3,x * 1,0.98,1.05,Water density
AquaTroll,Resistivity600,gw_resistivity,,,x * 1,,,CHECK
AquaTroll,pH600,gw_ph,unitless,unitless,x * 1,0,14,Water pH
AquaTroll,pH_mV600,gw_ph_mv,mV,mV,x * 1,,,CHECK
AquaTroll,pH_ORP600,gw_ph_orp,mV,mV,x * 1,-1400,1400,Water oxidation-reduction potential
AquaTroll,RDO_concen600,gw_rdo_concentration,mg/L,mg/L,x * 1,0,20,Dissolved oxygen concentration
AquaTroll,RDO_concen600,gw_rdo_conc,mg/L,mg/L,x * 1,0,20,Dissolved oxygen concentration
AquaTroll,RDO_perc_sat600,gw_perc_sat,,,x * 1,,,CHECK
AquaTroll,RDO_part_Pressure600,gw_part_pressure,,,x * 1,,,CHECK
AquaTroll,Pressure600,gw_pressure,psi,mbar,x * 68.948,-10,910,Vented pressure (corrected for barometric pressure)
AquaTroll,Depth600,gw_depth,,,x * 1,,,CHECK
AquaTroll,Voltage_Ext600,gw_voltage_ext,V,V,x * 1,,,CHECK
AquaTroll,Battery_Int600,gw_battery,V,V,x * 1,,,CHECK
ClimateVue,,wx_rain,?,?,x * 1,,,
ClimateVue,,wx_winddir,?,?,x * 1,,,
ClimateVue,,wx_maxws,?,?,x * 1,,,
Expand Down
Loading