CODE | NAME | TYPE | MEMO | What to do |
---|---|---|---|---|
1 | CODE_IDLE | WARN | Idle | Check if the network is ok or AUC work normally |
2 | CODE_MMCRCFAILED | WARN | IIC rx irc mismatch was found | Ignore it please, If CGMiner is restart, It will be ok. |
4 | CODE_NOFAN | FATAL | Fan cann't be found | Check the fan connection |
8 | CODE_LOCK | WARN | Reserved | Ask for unlock service |
16 | CODE_APIFIFOOVERFLOW | WARN | API fifo overflow flag | It's just a notice on api fifo |
32 | CODE_RBOVERFLOW | WARN | Nonce ringbuffer overflow | Ignore it please, If CGMiner is restart, It will be ok. |
64 | CODE_TOOHOT | FATAL | The modular or mm board is too hot | Check the fan or replace the too hot module |
128 | CODE_HOTBEFORE | WARN | Toohot was found on MM | It's just a notice for too hot modular |
256 | CODE_LOOPFAILED | FATAL | loopback test failed | The led will turn to red. Ignore it if hashrate is not so bad. |
512 | CODE_CORETESTFAILED | WARN | Core test failed | Ignore it if hashrate is not so bad |
1024 | CODE_INVALIDPMU | FATAL | Invalid pmu firmware version or pmu is broken | Replace a new pmu |
2048 | CODE_PGFAILED | FATAL | Power not good | Check the PMU |
4096 | CODE_NTC_ERR | FATAL | Temperature sensor check failed | Replace the module which the code was found on. |
8192 | CODE_VOL_ERR | FATAL | Voltage input sensor check failed | Replace the module which the code was found on. |
16384 | CODE_VCORE_ERR | FATAL | Voltage output sensor check failed | Replace the module which the code was found on. |
32768 | CODE_PMUCRCFAILED | WARN | It's just a notice | Ignore it please |
65536 | CODE_INVALID_PLL_VALUE | WARN | PLL configration check failed | Reboot the modular, if not good then try to replace the module. |
131072 | CODE_HUFAILED | WARN | HU configration check failed | Reboot the modular, if not good then try to replace the HU. |
'''WARN'''-It designates potentially harmful situations, but you can ignore it. '''FATAL'''-It designates very severe error events that will presumably lead the Avalon7 to crash.
错误码 | 名称 | 类型 | 问题 | 如何处理 |
---|---|---|---|---|
1 | CODE_IDLE | 提示 | 空闲 | 检查网络连接,检查AUC3,检查AUC3数据线是否正常以及正确连接 |
2 | CODE_MMCRCFAILED | 提示 | MM数据通信中有CRC错误 | 忽略 |
4 | CODE_NOFAN | 警告 | 没有检测到风扇 | 检查风扇连接线是否松动,最后尝试更换风扇 |
8 | CODE_LOCK | 提示 | 保留 | 忽略 |
16 | CODE_APIFIFOOVERFLOW | 提示 | API缓冲区溢出标示 | 忽略 |
32 | CODE_RBOVERFLOW | 提示 | NONCE缓冲区溢出标示 | 忽略 |
64 | CODE_TOOHOT | 警告 | MM、PMU或者算力板过热 | 检查风扇,检查进气口温度,检查环境温度 |
128 | CODE_HOTBEFORE | 提示 | 曾经出现过过热保护的情况 | 忽略 |
256 | CODE_LOOPFAILED | 提示 | 回环测试提示 | 忽略 |
512 | CODE_CORETESTFAILED | 提示 | 芯片测试提示 | 忽略 |
1024 | CODE_INVALIDPMU | 警告 | PMU没有检测到 | 更新PMU固件,如果不能修复需更换PMU |
2048 | CODE_PGFAILED | 警告 | 供电异常 | 检查电源,检查电源连接线,最后检查PMU是否损坏 |
4096 | CODE_NTC_ERR | 警告 | PMU上温度传感器检查失败 | 更换相应模块,保存PMU模块用于北京工厂返修 |
8192 | CODE_VOL_ERR | 警告 | 模组电压输入检测失败 | 检查电源, 检查电源连接线,更换PMU |
16384 | CODE_VCORE_ERR | 警告 | 模组电压输出检测失败 | 检查电源, 检查电源连接线,更换PMU |
32768 | CODE_PMUCRCFAILED | 提示 | PMU通信中有CRC错误 | 忽略 |
65536 | CODE_INVALID_PLL_VALUE | 提示 | PLL配置检测失败 | 重启模组 |
131072 | CODE_HUFAILED | 提示 | HU配置检测失败 | 重启模组, 如果此HU配置检测仍失败,则更换此HU |