Notifications
You must be signed in to change notification settings - Fork 1.2k
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Currently translated at 96.2% (31770 of 33005 strings) Author: Hans Unzner <[email protected]> Co-authored-by: Hans Unzner <[email protected]> Translate-URL: https://hosted.weblate.org/projects/linuxcnc/linuxcnc-docs/de/ Translation: LinuxCNC/LinuxCNC Documentation
- Loading branch information
Showing
1 changed file
with
12 additions
and
10 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -15,7 +15,7 @@ msgstr "" | |
"Project-Id-Version: PACKAGE VERSION\n" | ||
"Report-Msgid-Bugs-To: [email protected]\n" | ||
"POT-Creation-Date: 2024-10-05 14:14+0200\n" | ||
"PO-Revision-Date: 2024-11-04 20:46+0000\n" | ||
"PO-Revision-Date: 2024-11-08 09:25+0000\n" | ||
"Last-Translator: Hans Unzner <[email protected]>\n" | ||
"Language-Team: none\n" | ||
"Language: de\n" | ||
|
@@ -145919,7 +145919,9 @@ msgstr "link:../man/man9/and2.9.html[and2]" | |
#: src/hal/components.adoc:166 | ||
#, no-wrap | ||
msgid "Two-input AND gate. For out to be true both inputs must be true. (link:../man/man9/and2.9.html[and2])" | ||
msgstr "UND-Gatter mit zwei Eingängen. Damit der Ausgang wahr ist, müssen beide Eingänge wahr sein. (Link:../man/man9/and2.9.html[and2])" | ||
msgstr "" | ||
"UND-Gatter mit zwei Eingängen. Damit der Ausgang wahr ist, müssen beide " | ||
"Eingänge wahr sein. (link:../man/man9/and2.9.html[and2])" | ||
|
||
#. type: Table | ||
#: src/hal/components.adoc:167 | ||
|
@@ -227626,14 +227628,14 @@ msgid "" | |
"current." | ||
msgstr "" | ||
"Als Beispiel: Das typische Relais, das in einem Hypertherm Powermax 65 " | ||
"Plasmaschneider verwendet wird (Link:https://www.te.com/commerce/" | ||
"DocumentDelivery/DDEController?" | ||
"Action=showdoc&DocId=Data+Sheet%7F1308242_T77%7F1011%7Fpdf%7FEnglish%7FENG_DS_1308242_T77_1011." | ||
"pdf%7F1-1393194-0[TE T77S1D10-24]), erfordert eine minimale Kontaktbelastung " | ||
"von 100 mA bei 5 VDC, was 0,5 W (P = I * V) abgibt. Bei " | ||
"Verwendung einer 24 VDC-Stromversorgung würde dies einem Mindeststrom " | ||
"von 20,8 mA entsprechen. Da der vom Mesa-Eingang aufgenommene Strom " | ||
"geringer ist als der vom Relais benötigte, muss der Strom erhöht werden." | ||
"Plasmaschneider verwendet wird (link:https://www.te.com/commerce/" | ||
"DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7F1308242_T77%" | ||
"7F1011%7Fpdf%7FEnglish%7FENG_DS_1308242_T77_1011.pdf%7F1-1393194-0[TE " | ||
"T77S1D10-24]), erfordert eine minimale Kontaktbelastung von 100 mA bei " | ||
"5 VDC, was 0,5 W (P = I * V) abgibt. Bei Verwendung einer " | ||
"24 VDC-Stromversorgung würde dies einem Mindeststrom von 20,8 mA " | ||
"entsprechen. Da der vom Mesa-Eingang aufgenommene Strom geringer ist als " | ||
"der vom Relais benötigte, muss der Strom erhöht werden." | ||
|
||
#. type: Plain text | ||
#: src/plasma/qtplasmac.adoc:442 | ||
|