Each junior is set up to connect to the next junior in link mode on output 1, a group of five LED buttons on output 2, and a 12v relay on output 3, which powers a 24v maglock. The first junior powers its its own buttons with the power terminals, the last junior does not power any buttons. Each junior is powered with in parallel with a 12v5a dc power supply.
Each junior will wait for its five inputs to open in order, open the maglock for a second, close the maglock, and then enable the next keeper and power its inputs. This way players progress through the puzzle five inputs at a time, and they can see the next five light up after each section is solved.
- Hold button 3 and plug the 12v dc power cable into the side of the escape keeper.
- Use the volume knob and button 3 to select the following indicators in order:
- 1
- 5
- 7
- 1
- 1
- 1
- none
- Push all LED buttons in
- Push REC
- Push LED buttons in order
- Push REC
- Push the next five LED buttons in
- Hold REC and wait for the indicators to light up
- Keep holding REC and use the volume knob to select indicator 6
- Release REC
- Tap REC
- Push button 2 for one second, the mag lock should close
- Release button 2, hold button 3, the next five LED buttons should light up
- Keep holding button 3 and tap REC, then release button 3
- Hold button 3 to save the animation, or go back to step 4 to record again