MikroE


Temp_Log_3 Click

  • CIC Prefix : TEMPLOG3
  • Author : Nemanja Medakovic
  • Verison : 1.0.0
  • Date : Dec 2018.

Software Support

We provide a library for the Temp_Log_3 Click on our LibStock page, as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Library Description

The library performs a control of the Temp-Log 3 Click board. There are a functions that offer a choice to measure the ambient temperature and set a temperature limit values to generate alarm. The library also can save a desired configurations or temperature values to the EEPROM, which has size of 256 bytes. For more details check documentation.

Key functions :

  • T_TEMPLOG3_RETVAL templog3_writeReg( uint8_t regAddr, uint16_t dataIn ) - Function writes a 16bit data to the desired register.
  • T_TEMPLOG3_RETVAL templog3_getTemp( uint8_t tempSel, T_TEMPLOG3_DEG *tempOut ) - Function gets a temperature value from the desired temperature register calculated to the Celsius degrees.
  • T_TEMPLOG3_RETVAL templog3_setTemp( uint8_t tempSel, T_TEMPLOG3_DEG tempIn ) - Function sets a desired temperature register on the desired value calculated to the Celsius degrees.
  • void templog3_eepromByteWrite( uint8_t regAddr, uint8_t dataIn, uint8_t eepromMode ) - Function writes a one byte data to the EEPROM including/excluding a write protection.

Examples Description

The application is composed of three sections :

  • System Initialization - Initializes peripherals and pins.
  • Application Initialization - Initializes I2C interface and performs a device configuration for properly working. Also sets the temperature limit to the desired values.
  • Application Task - (code snippet) - First ensures that the minimum conversion time is met, and then reads the ambient temperature calculated to the Celsius degrees. Also checks the limit status and shows a message when some limit condition is met. Note : The temperature range that can be measured or written is from -40 to +125 Celsius degrees. The user can change the measured temperature resolution, but the range remains the same. The limit temperature resolution is always a 10bit, or 0.25 Celsius degrees. If user wants to enable the EEPROM Write Protection, the A0 pin on the device must be set to the high voltage level.
void applicationTask()
{
    templog3_waitConvDone();

    retStatus = templog3_getTemp( _TEMPLOG3_TEMP_AMBIENT_REG, &temperature );
    
    FloatToStr( temperature, text );
    floatCut();
    mikrobus_logWrite( "**  Ambient temperature is : ", _LOG_TEXT );
    mikrobus_logWrite( text, _LOG_TEXT );
    logUnit();
    mikrobus_logWrite( "  **", _LOG_LINE );
    
    checkLimitStatus();
    
    Delay_ms( 300 );
}

Additional Functions :

  • floatCut - Makes that float values be rounded on two decimal places.
  • logUnit - Writes a Celsius degrees symbol on uart terminal.
  • checkLimitStatus - Checks the limit status for each temperature reading cycle and writes a message on uart terminal when some limit condition is met.

The full application code, and ready to use projects can be found on our LibStock page.

Other mikroE Libraries used in the example:

  • Conversions
  • I2C
  • UART

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.