Hydro failing when using grass pft sapwood allometry function (allom_smode = 2
)
#1254
Comments
@XiulinGao has proposed some solutions via #1136 (comment):
|
This is a temporary update to avoid NGEET/fates#1254 and should be removed once a fix comes in on the fates-side.
@rgknox suggested during the software meeting today that we could add a gracefully failure to the model for note this for the time being as well. |
I am leaning towards option 1 after some thinking. We can think the max. conductance calculated using option one is a collective behavior of all grass tillers, which make it easier to think of hydro failure at the entire plant level. It's similar to the sapwood of woody plants. Think of grass tiller as xylem (basic water transporting unit) and the whole trunk as sapwood. I can implement the calculation for sapwood area quick for smode 2 if we go with option 1. |
This update calls the fates parameter modification tooling to set the grass allometry smode to 1, which is the default for all other fates PFTs. This is a temporary workaround for NGEET/fates#1254.
This was discovered during testing for #1136:
Originally posted by @glemieux in #1136 (comment)
The text was updated successfully, but these errors were encountered: