Skip to content

zib-O2Saturation

zib-O2Saturation #583

Triggered via pull request January 17, 2025 12:21
Status Success
Total duration 2m 2s
Artifacts

qa-changed.yml

on: pull_request
Strict QA on changed materials
1m 53s
Strict QA on changed materials
Fit to window
Zoom out
Zoom in

Annotations

10 warnings and 2 notices
Strict QA on changed materials
ubuntu-latest pipelines will use ubuntu-24.04 soon. For more details, see https://github.com/actions/runner-images/issues/10636
Strict QA on changed materials: examples/nl-core-O2Saturation-full-01-AnatomicalLocation.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at BodyStructure)
Strict QA on changed materials: examples/nl-core-O2Saturation-01.xml#L44
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://loinc.org#2708-6, http://loinc.org#59408-5) (at Observation.code)
Strict QA on changed materials: examples/nl-core-O2Saturation-01.xml#L72
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://snomed.info/sct#266702001) (at Observation.component[0].code)
Strict QA on changed materials: examples/nl-core-O2Saturation-01.xml#L44
Wrong Display Name 'Zuurstofverzadiging in arterieel bloed d.m.v. pulsoxymetrie' for http://loinc.org#59408-5. There are no valid display names found for language(s) 'en'. Default display is 'Oxygen saturation in Arterial blood by Pulse oximetry' (at Observation.code.coding[1].display)
Strict QA on changed materials: examples/nl-core-O2Saturation-01.xml#L44
Wrong Display Name 'Zuurstofverzadiging in arterieel bloed' for http://loinc.org#2708-6. There are no valid display names found for language(s) 'en'. Default display is 'Oxygen saturation in Arterial blood' (at Observation.code.coding[0].display)
Strict QA on changed materials: examples/nl-core-O2Saturation-full-01.xml#L50
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://loinc.org#2708-6, http://loinc.org#59408-5) (at Observation.code)
Strict QA on changed materials: examples/nl-core-O2Saturation-full-01.xml#L92
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://snomed.info/sct#266702001) (at Observation.component[0].code)
Strict QA on changed materials: examples/nl-core-O2Saturation-full-01.xml#L50
Wrong Display Name 'Zuurstofverzadiging in arterieel bloed d.m.v. pulsoxymetrie' for http://loinc.org#59408-5. There are no valid display names found for language(s) 'en'. Default display is 'Oxygen saturation in Arterial blood by Pulse oximetry' (at Observation.code.coding[1].display)
Strict QA on changed materials: examples/nl-core-O2Saturation-full-01.xml#L50
Wrong Display Name 'Zuurstofverzadiging in arterieel bloed' for http://loinc.org#2708-6. There are no valid display names found for language(s) 'en'. Default display is 'Oxygen saturation in Arterial blood' (at Observation.code.coding[0].display)
Strict QA on changed materials: examples/nl-core-O2Saturation-01.xml#L1
Validate Observation against the Oxygen saturation profile (http://hl7.org/fhir/StructureDefinition/oxygensat) which is required by the FHIR specification because the LOINC code 2708-6 was found (at Observation)
Strict QA on changed materials: examples/nl-core-O2Saturation-full-01.xml#L1
Validate Observation against the Oxygen saturation profile (http://hl7.org/fhir/StructureDefinition/oxygensat) which is required by the FHIR specification because the LOINC code 2708-6 was found (at Observation)