Zib-BloodPressure #592
qa-changed.yml
on: pull_request
Strict QA on changed materials
2m 39s
Annotations
1 error, 11 warnings, and 10 notices
Strict QA on changed materials:
zib/StructureDefinitions/zib-BloodPressure.xml#L1
An ignored issue was provided, but the issue didn't occur (at zib-BloodPressure)
|
Strict QA on changed materials
ubuntu-latest pipelines will use ubuntu-24.04 soon. For more details, see https://github.com/actions/runner-images/issues/10636
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02-AnatomicalLocation.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at BodyStructure)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-01-AnatomicalLocation.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at BodyStructure)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L73
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://loinc.org#85354-9) (at Observation.code)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L104
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://loinc.org#8480-6) (at Observation.component[0].code)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L119
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://loinc.org#8462-4) (at Observation.component[1].code)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L134
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://snomed.info/sct#70665002) (at Observation.component[2].code)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L73
Wrong Display Name 'Bloeddruk panel waarvan alle leden optioneel in arterieel vaatstelsel' for http://loinc.org#85354-9. There are no valid display names found for language(s) 'en'. Default display is 'Blood pressure panel with all children optional' (at Observation.code.coding[0].display)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L104
Wrong Display Name 'Intravasculaire systolische bloeddruk in arterieel vaatstelsel' for http://loinc.org#8480-6. There are no valid display names found for language(s) 'en'. Default display is 'Systolic blood pressure' (at Observation.component[0].code.coding[0].display)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L119
Wrong Display Name 'Intravasculaire diastolische bloeddruk in arterieel vaatstelsel' for http://loinc.org#8462-4. There are no valid display names found for language(s) 'en'. Default display is 'Diastolic blood pressure' (at Observation.component[1].code.coding[0].display)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-full-01.xml#L93
None of the codings provided are in the value set 'Vital Signs' (http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1), and a coding should come from this value set unless it has no suitable code (note that the validator cannot judge what is suitable) (codes = http://loinc.org#85354-9) (at Observation.code)
|
Strict QA on changed materials:
zib/vocabulary/generated/CodeSystem-Unified_Code_for_Units_of_Measure-unitsofmeasure.org.xml#L1
CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly (at CodeSystem)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L1
Validate Observation against the Blood pressure systolic and diastolic profile (http://hl7.org/fhir/StructureDefinition/bp) which is required by the FHIR specification because the LOINC code 85354-9 was found (at Observation)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L133
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (at Observation.component[2])
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-02.xml#L141
'Groot' is the default display; the code system urn:oid:2.16.840.1.113883.2.4.3.11.60.40.4.15.1 has no Display Names for the language en (at Observation.component[2].value.ofType(CodeableConcept).coding[0].display)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-full-01.xml#L1
Validate Observation against the Blood pressure systolic and diastolic profile (http://hl7.org/fhir/StructureDefinition/bp) which is required by the FHIR specification because the LOINC code 85354-9 was found (at Observation)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-full-01.xml#L150
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (at Observation.component[2])
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-full-01.xml#L166
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (at Observation.component[3])
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-full-01.xml#L183
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (at Observation.component[4])
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-01.xml#L1
Validate Observation against the Blood pressure systolic and diastolic profile (http://hl7.org/fhir/StructureDefinition/bp) which is required by the FHIR specification because the LOINC code 85354-9 was found (at Observation)
|
Strict QA on changed materials:
examples/nl-core-BloodPressure-01.xml#L130
This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.0.1 (this may not be a problem, but you should check that it's not intended to match a slice) (at Observation.component[2])
|