Common

Edge

  • WAGO: compatibility with newer fieldbus couplers + all kinds of digital output modules (#1136)
    • Tries to read old 'ea-config.xml' and new 'io_config.xml'
    • Dynamically reads the number of output channels from xml file for WAGO 750 5xx-modules
  • Meter Carlo Gavazzi EM300: add invert config setting (#1140)
  • Improvements to GoodWe ET implementation (#1141)
    • Added the max apparent power reading from ModBus register. and also few code refactoring.

UI

  • Collected UI improvements (#1143)
    • add possibility to pick level when heatingelement is set to MANUAL_ON in heatingelement advanced widget
    • add help button which links to openems.io docs for chpsoc, evcs, singlethreshold, heatingelement and fixdigitaloutput
    • add metered consumption to consumption flat and advanced widget
    • remove workmode kwh from heatingelement advanced widget