Version 3.4.0
00_SIGNALduino.pm
- Option to reconstruct last bit of transmission in MU and MS signals if there is enough data to detect it. #518
- Moved protocol hash into a separate perl module instead of loading a simple textfile into a variable. #522
- new module for Keeloq devices (#520)
-
added new model TR-502MSV (LIBRA GmbH) [LIDL]
-
Reworked internal location of protocol data
-
Added standard deviceOverview output in detail page #545
-
added new internal (Protocol_ID), which will provide the protocolID in logical modules.
-
added new internal LAST_Protocol_ID which holds the last successfull dispatched protocol id
-
made float a optional symbol in transmissions, same behaviour before #4880711
-
Drop-down list for set command config CC1101 (#589)
add drop-down list for cc1101_bWidth, cc1101_rAmpl and cc1101_sens -
fix break & WARNING (#592)
-
Fix regex for optional float in parse_mu (#597)
-Support MS signal with multiple syncs (#601)
- Update SD_ProtocolData.pm (#603)
SD_ProtocolData.pm:
- revised ID46 and ID78 (GEIGER blind motors) removed
- ID 46 is now Tedsen remote for Berner Garagentorantrieb GA401 and Geiger Antriebstechnik Rolladensteuerung)
- added ID94 for #547
- Atech wireless weather station
- set protocol 94 as development
- new definition protocol 95 (Techmar)
- removed zero key from protocol 76 to avoid perl warning fixes: #156
- cleanup comments
- added Grothe Mistral protocol id 96 (#590)
- OpusXT300 reconstructBit für protokoll 50 aktiviert und protokolldaten hinterlegt (fixes #580)
14_SD_Keeloq.pm
- fix PERL WARNING if hlen a other typ of device
- fixed channels 10-16
14_SD_WS07.pm
- Autocreate bug with wrong DEF code fixed #531
- Loglevel for wrong values rises to verbose #543
- new sensor for weather station Auriol AFW 2 A1, IAN: 297514 (#605)
14_SD_WS.pm:
- correct longid from 12 to 8 bit, valid channels only 1-3
- New protocol for Atech wireless weather station (#578)
- added new sensor TECVANCE TV-4848 (#599)
14_SD_UT.pm:
- revised Tedsen models | TEDSEN_SKX1MD OLD rename to TEDSEN_SKX1xx because other new models TEDSEN_SKX2xx,TEDSEN_SKX4xx,TEDSEN_SKX6xx
- !! Old model TEDSEN_SKX1MD delete and autocreate to TEDSEN_SKX1xx | remotes with different number of buttons !!
- new protocol for Techmar Garden Lights
- fixed Manax creation (no device after dispatch and model selection)
- fixed ESTO KL_RF01
- added commandref & information
- rename model Manax to RC_10 (Manax | mumbi are the same typ´s)
- Add checksum for protocol 66 (WS7035) (#606)
- Manax and mumbi device (RC_10) added send commands
14_SD_RSL.pm:
changed set loglevel from 4 to 3 and improved rasability
14_SD_BELL - fixed repeats (#593)
- added fix repeats for model Heidemann_|Heidemann_HX|_VTX-BELL #367 (comment)