How to: Conditional input connectors
This page describes how to model conditional input connectors following the practice of the Modelica IBPSA Library.
You want to model a component that needs an input from outside and you want the users to decide on whether
- to provide the input value as a parameter or
- to provide the input via an optional connector (in this case the input can be a fixed value or a time series).
The Modelica IBPSA Library provides some models that implement the above use case to AixLib. One of these models is AixLib.Fluid.Sources.Boundary_pT
. The model uses e.g. the Boolean parameter use_p_in
to specify the input for the source's pressure. From the model's documentation:
If use_p_in is false (default option), the p parameter is used as boundary pressure, and the p_in input connector is disabled; if use_p_in is true, then the p parameter is ignored, and the value provided by the input connector is used instead. The same applies to the temperature, composition and trace substances.
Let's say we want to model a conditional input connector for the prescribed heat flow rate that our model should extract from or add to a fluid stream. Therefore, we use the parameter use_Q_in
to decide between inputs from the parameter precribedQ
and the conditional input connector Q_in
.
To begin, we add the Boolean decision parameter to our model:
parameter Boolean use_Q_in = false
"Get the prescribed heat flow rate from the input connector"
annotation(Evaluate=true, HideResult=true);
Next, we define the parameter prescribedQ
and annotate it to only be enabled if use_Q_in
is false
:
parameter Modelica.SIunits.HeatFlowRate prescribedQ
"Fixed value of prescribed heat flow rate"
annotation (Dialog(enable = not use_Q_in));
In addition, we define the input connector Q_in
. The if use_Q_in
makes the use of this connector conditional on the value of use_Q_in
:
Modelica.Blocks.Interfaces.RealInput Q_in(final unit="W") if use_Q_in
"Prescribed heat flow rate connector"
annotation (Placement(transformation(extent={{-140,60},{-100,100}})));
After defining the inputs, we also have to define an internal connector Q_in_internal
. As this is only needed internally, we will make that protected
:
protected
Modelica.Blocks.Interfaces.RealInput Q_in_internal(final unit="W")
"Needed to connect to conditional connector";
Now we can put all these options together in the equation
section. First, we'll connect Q_in
to Q_in_internal
equation
connect(Q_in, Q_in_internal);
Now, if the users do not want to use the conditional connector, we use an if
-clause to set Q_in_internal
to the value of prescribedQ
for this case:
if not use_Q_in then
Q_in_internal = prescribedQ;
end if;
From here on, we can use the variable Q_in_internal
in all our further equations to work with the conditional input.
This approach is taken from the Modelica IBPSA Library, thanks to the developers for coming up with this solution
If
- anything on this page is not clear to you,
- you found an error on this page,
- you have a suggestion for improvement,
- you experience a problem with this approach in your branch of AixLib,
- you have a better solution for modeling conditional input connectors,
- ...
Make sure to raise the issue on our Issue Tracker!
- Getting started
-
Modeling and simulation guide
- Modelica guidelines
- How to Modelica
- Important tools around AixLib
- Move from HeatPump to ModularReversible
-
Contribution guide
- Git Workflow
- Structure of Repository
- Behind the Scenes
- Contribute to AixLib
- Testing and model quality management
- Requirements
- Test Management
- Continuous Integration