Add documentation to the cascading PID logic.
Browse files Browse the repository at this point in the history
  • Loading branch information
deiger committed Jan 31, 2025
1 parent 381ad3e commit b3219e9
Showing 1 changed file with 31 additions and 0 deletions.
31 changes: 31 additions & 0 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -79,6 +79,28 @@ climate:
pwm: 0
```

```
climate:
- platform: smart_thermostat
name: Smart Thermostat Cascading PID Example
unique_id: smart_thermostat_outer_pid_example
heater: climate.smart_thermostat_single_on_off_heat_example
target_sensor: sensor.ambient_temperature2
min_temp: 7
max_temp: 28
ac_mode: False
target_temp: 19
keep_alive:
seconds: 60
away_temp: 14
kp: 5
ki: 0.01
kd: 500
output_min: 7
output_max: 28
pwm: 0
```

## Usage:
The target sensor measures the ambient temperature while the heater switch controls an ON/OFF
heating system.\
Expand Down Expand Up @@ -123,6 +145,15 @@ PID output value is the weighted sum of the control terms:\
`output = P + I + D`\
Output is then limited to 0% to 100% range to control the PWM.

#### Cascading PID
Optionally, 2 (or more) PIDs can be used in a cascading matter, e.g. for underfloor heating define an outer
PID between the room temperature and the floor temperature, and an inner PID between the floor
temperature and the PWM. See details [here](
https://en.wikipedia.org/wiki/Proportional%E2%80%93integral%E2%80%93derivative_controller#Cascade_control).

To enable, create the inner thermostate as detailed above, and then create another thermostate that will
control the inner one.

#### Outdoor temperature compensation
Optionally, when an outdoor temperature sensor entity is provided and ke is set, the thermostat can
automatically compensate building losses based on the difference between target temperature and