Danfoss Binding

This binding allows you to integrate heating solutions by Danfoss company. These solutions communicate over Wi-Fi using a proprietary cloud via a protocol called SecureDeviceGrid(tm) (http://securedevicegrid.com/).

The cloud solution is developed by Trifork company. This binding relies on OpenSDG (https://github.com/Sonic-Amiga/opensdg), the free and opensource implementation of this protocol. The library must be installed in your system in order for this binding to operate.

Supported Things

Note that Danfoss Icon support is currently incomplete and in beta state. It was done entirely with user's support; i, the developer, don't have Icon hardware on my disposal.

Installation and supported architectures

This binding relies on OpenSDG library (https://github.com/Sonic-Amiga/opensdg/releases) for communicating with the hardware. On Linux OS It is necessary to manually install the library in your system before using this binding. On Windows no extra components need to be installed.

Currently the following architectures / operating systems are supported:

  • Windows / x86_64
  • Linux / x86_64
  • Linux / i386
  • Linux / ARM hardfloat (armhf) 32-bit
  • Linux / arm64

Discovery

Unfortunately automatic discovery of Danfoss devices is technically very problematic and cannot be reliably performed in OpenHAB (or any other home automation) environment. Instead, it is supposed to set the hardware up using original smartphone application according to product manual; and then share the configuration with OpenHAB.

  1. Navigate to http://YOUR_OPENHAB_HOST:8080/danfoss/
  2. According to instructions in the form, use "Share house" function in your DeviReg(tm) Smart smartphone application.
  3. Enter the One Time Password, issued by the phone, in the form and click "Receive"
  4. On success a message is displayed, telling number of things received.
  5. Navigate to Inbox, review and approve your Things

Binding Configuration

Parameter Meaning
privateKey Private key, used for communication.
publicKey Public key, also known as Peer ID. All devices on the Grid are identified by these keys.
userName User name, which will represent the OpenHAB in DeviReg(tm) Smart smartphone application. Used for configuration sharing.

User name is the only parameter to actually be set by the user.

Keys are vital for functioning of the binding. A valid key pair is generated automatically upon first run and stored in the configuration. Unless you exactly know what you're doing and why, do not modify the private key, or you'll lose access to all your thermostats and will have to perform configuration sharing again!!! For the sake of safety, keys are made read-only in the interface, but you still can freely edit them in expert mode. A public key is always derived from the private key and any attempts to modify it will be reverted. It is provided for information purposes only, should there arise such a need.

Thing Configuration

DeviReg Smart and Icon Controller

The only parameter here is peerId. Being thermostat's public key, it identifies the thermostat on the Grid. It is made read-only in the interface in order to prevent accidental damage. Unfortunately it is not written on the device, nor in the manual. The only way to obtain this ID is to receive the configuration from the original smartphone application.

Icon room

roomNumber - ordinal number of the room in Icon system

Channels

Channels, supported by DeviReg Smart(tm) thermostat:

channel type description Read-only
temperature_floor Temperature Floor temperature sensor reading Y
temperature_room Temperature Room temperature sensor reading Y
setpoint_comfort Temperature Set point for "At home" period N
setpoint_economy Temperature Set point for "Away/Asleep" period N
setpoint_manual Temperature Set point for manual mode N
setpoint_away Temperature Set point for vacation mode N
setpoint_antifreeze Temperature Set point for frost protection (paused) mode N
setpoint_min_floor Temperature Minimum floor temperature N
setpoint_min_floor_enable Switch Enable keeping minimum floor temperature N
setpoint_max_floor Temperature Maximum allowed floor temperature N
setpoint_warning Temperature Temperature below which an alarm notification is sent to your phone N
control_mode String Chosen control mode: MANUAL, OVERRIDE, SCHEDULE, VACATION, PAUSE, OFF N
control_state String Current control state: CONFIGURING, MANUAL, HOME, AWAY, VACATION, FATAL, PAUSE, OFF, OVERRIDE Y
window_detection Switch Enable or disable open window detection N
window_open Switch Whether an open window is detected in the room Y
forecast Switch Attempt to forecast heating and provide desired temperature at desired time N
screen_lock Switch Thermostat sensor controls lock N
brightness Number Thermostat screen brightness, from 10 to 100 Y
heating_state Switch Current heater state, on / off Y
on_time_7_days Time Summary heater on time for the last 7 days Y
on_time_30_days Time Summary heater on time for the last 14 days Y
on_time_total Time Total heater on time Y
sensor_disconnected Switch Temperature sensor fault flag: disconnected Y
sensor_shorted Switch Temperature sensor fault flag: short circuit Y
overheat Switch Thermostat fault flag: floor overheated Y
unrecoverable Switch Internal thermostat fault flag Y

Channels, supported by Icon Master:

channel type description Read-only
setpoint_away Temperature Set point for vacation mode N
setpoint_antifreeze Temperature Set point for frost protection (paused) mode N

Channels, supported by Icon Room:

channel type description Read-only
temperature_floor Temperature Floor temperature sensor reading Y
temperature_room Temperature Room temperature sensor reading Y
setpoint_comfort Temperature Set point for "At home" period N
setpoint_economy Temperature Set point for "Away" period N
setpoint_asleep Temperature Set point for "Asleep" period N
setpoint_min_floor Temperature Minimum floor temperature N
setpoint_max_floor Temperature Maximum allowed floor temperature N
manual_mode Switch Manual mode on/off N
control_state String Current control state: HOME, AWAY, ASLEEP, FATAL Y
battery Number Battery charge percentage for wireless thermostats Y

NOTES:

  1. Push notifications are sent directly by the thermostat via original Danfoss cloud infrastructure, this is part of the original service. OpenHAB takes no part in this process.
  2. Communication with the hardware is currently possible only via the cloud infrastructure. Therefore a working Internet connection is required for the binding to operate, even if the OpenHAB installation resides on the same network with thermostats. This is a restriction of thermostat's firmware and cannot be fixed.
  3. For DeviReg Smart: If there's no "at home" time configured in the schedule for the given day, OVERRIDE mode does not work and immediately falls back to SCHEDULE. This is a bug in thermostat's firmware, OpenHAB does not affect this.