Skip to content

Commit

Permalink
[FIX] Clean up qMRI RB1COR notes (#1465)
Browse files Browse the repository at this point in the history
* Fix reference to transmit coils in RB1COR description

* Clarify RB1COR images acquired sequentially

---------

Co-authored-by: Luke Edwards <[email protected]>
  • Loading branch information
lukeje and Luke Edwards authored May 2, 2023
1 parent ae93938 commit 6c5b34d
Showing 1 changed file with 6 additions and 3 deletions.
9 changes: 6 additions & 3 deletions src/appendices/qmri.md
Original file line number Diff line number Diff line change
Expand Up @@ -706,9 +706,12 @@ The example above applies to the `TB1RFM` suffix as well.

#### `RB1COR` specific notes

This method generates a sensitivity map by combining two low resolution images
collected by two transmit coils (the body and the head coil) upon subsequent scans
with identical acquisition parameters.
This method generates a receive sensitivity map by combining two low resolution images
collected sequentially by two different RF coils in receive mode (the body and the head coil)
with otherwise identical acquisition parameters.
To correct for dynamic changes in the receive sensitivity over time due to, for example,
subject motion, separate receive sensitivity maps may be acquired for each anatomical
acquisition in a file collection.

To properly identify constituents of this particular method, values of the `acq`
entity SHOULD begin with either `body` or `head` and MAY be followed by freeform
Expand Down