-
Notifications
You must be signed in to change notification settings - Fork 16
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Auto-Update: 2024-12-11T13:01:43.009958+00:00
- Loading branch information
1 parent
7b8ad83
commit 7642689
Showing
18 changed files
with
864 additions
and
40 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,100 @@ | ||
{ | ||
"id": "CVE-2024-10511", | ||
"sourceIdentifier": "[email protected]", | ||
"published": "2024-12-11T09:15:05.293", | ||
"lastModified": "2024-12-11T09:15:05.293", | ||
"vulnStatus": "Received", | ||
"cveTags": [], | ||
"descriptions": [ | ||
{ | ||
"lang": "en", | ||
"value": "CWE-287: Improper Authentication vulnerability exists that could cause Denial of access to the web interface\nwhen someone on the local network repeatedly requests the /accessdenied URL." | ||
} | ||
], | ||
"metrics": { | ||
"cvssMetricV40": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Secondary", | ||
"cvssData": { | ||
"version": "4.0", | ||
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", | ||
"baseScore": 6.3, | ||
"baseSeverity": "MEDIUM", | ||
"attackVector": "NETWORK", | ||
"attackComplexity": "LOW", | ||
"attackRequirements": "PRESENT", | ||
"privilegesRequired": "NONE", | ||
"userInteraction": "NONE", | ||
"vulnerableSystemConfidentiality": "NONE", | ||
"vulnerableSystemIntegrity": "NONE", | ||
"vulnerableSystemAvailability": "LOW", | ||
"subsequentSystemConfidentiality": "NONE", | ||
"subsequentSystemIntegrity": "NONE", | ||
"subsequentSystemAvailability": "NONE", | ||
"exploitMaturity": "NOT_DEFINED", | ||
"confidentialityRequirements": "NOT_DEFINED", | ||
"integrityRequirements": "NOT_DEFINED", | ||
"availabilityRequirements": "NOT_DEFINED", | ||
"modifiedAttackVector": "NOT_DEFINED", | ||
"modifiedAttackComplexity": "NOT_DEFINED", | ||
"modifiedAttackRequirements": "NOT_DEFINED", | ||
"modifiedPrivilegesRequired": "NOT_DEFINED", | ||
"modifiedUserInteraction": "NOT_DEFINED", | ||
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", | ||
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED", | ||
"modifiedVulnerableSystemAvailability": "NOT_DEFINED", | ||
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", | ||
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED", | ||
"modifiedSubsequentSystemAvailability": "NOT_DEFINED", | ||
"safety": "NOT_DEFINED", | ||
"automatable": "NOT_DEFINED", | ||
"recovery": "NOT_DEFINED", | ||
"valueDensity": "NOT_DEFINED", | ||
"vulnerabilityResponseEffort": "NOT_DEFINED", | ||
"providerUrgency": "NOT_DEFINED" | ||
} | ||
} | ||
], | ||
"cvssMetricV31": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Secondary", | ||
"cvssData": { | ||
"version": "3.1", | ||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", | ||
"baseScore": 5.3, | ||
"baseSeverity": "MEDIUM", | ||
"attackVector": "NETWORK", | ||
"attackComplexity": "LOW", | ||
"privilegesRequired": "NONE", | ||
"userInteraction": "NONE", | ||
"scope": "UNCHANGED", | ||
"confidentialityImpact": "NONE", | ||
"integrityImpact": "NONE", | ||
"availabilityImpact": "LOW" | ||
}, | ||
"exploitabilityScore": 3.9, | ||
"impactScore": 1.4 | ||
} | ||
] | ||
}, | ||
"weaknesses": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Primary", | ||
"description": [ | ||
{ | ||
"lang": "en", | ||
"value": "CWE-287" | ||
} | ||
] | ||
} | ||
], | ||
"references": [ | ||
{ | ||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-345-01.pdf", | ||
"source": "[email protected]" | ||
} | ||
] | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,60 @@ | ||
{ | ||
"id": "CVE-2024-11008", | ||
"sourceIdentifier": "[email protected]", | ||
"published": "2024-12-11T11:15:04.947", | ||
"lastModified": "2024-12-11T11:15:04.947", | ||
"vulnStatus": "Received", | ||
"cveTags": [], | ||
"descriptions": [ | ||
{ | ||
"lang": "en", | ||
"value": "The Members \u2013 Membership & User Role Editor Plugin plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 3.2.10 via the WordPress core search feature. This makes it possible for unauthenticated attackers to extract sensitive data from posts that have been restricted to higher-level roles such as administrator." | ||
} | ||
], | ||
"metrics": { | ||
"cvssMetricV31": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Primary", | ||
"cvssData": { | ||
"version": "3.1", | ||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", | ||
"baseScore": 5.3, | ||
"baseSeverity": "MEDIUM", | ||
"attackVector": "NETWORK", | ||
"attackComplexity": "LOW", | ||
"privilegesRequired": "NONE", | ||
"userInteraction": "NONE", | ||
"scope": "UNCHANGED", | ||
"confidentialityImpact": "LOW", | ||
"integrityImpact": "NONE", | ||
"availabilityImpact": "NONE" | ||
}, | ||
"exploitabilityScore": 3.9, | ||
"impactScore": 1.4 | ||
} | ||
] | ||
}, | ||
"weaknesses": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Primary", | ||
"description": [ | ||
{ | ||
"lang": "en", | ||
"value": "CWE-200" | ||
} | ||
] | ||
} | ||
], | ||
"references": [ | ||
{ | ||
"url": "https://plugins.trac.wordpress.org/changeset/3199682/members", | ||
"source": "[email protected]" | ||
}, | ||
{ | ||
"url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/0f6ad375-da04-4b56-8077-e26c148e7527?source=cve", | ||
"source": "[email protected]" | ||
} | ||
] | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,78 @@ | ||
{ | ||
"id": "CVE-2024-11401", | ||
"sourceIdentifier": "[email protected]", | ||
"published": "2024-12-11T10:15:06.013", | ||
"lastModified": "2024-12-11T10:15:06.013", | ||
"vulnStatus": "Received", | ||
"cveTags": [], | ||
"descriptions": [ | ||
{ | ||
"lang": "en", | ||
"value": "Rapid7 Insight Platform versions prior to November 13th 2024, suffer from a privilege escalation vulnerability whereby, due to a lack of authorization checks, an attacker can successfully update the password policy in the platform settings as a standard user by crafting an API (the functionality was not possible through the platform's User Interface). This vulnerability has been fixed as of November 13th 2024." | ||
} | ||
], | ||
"metrics": { | ||
"cvssMetricV40": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Secondary", | ||
"cvssData": { | ||
"version": "4.0", | ||
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", | ||
"baseScore": 5.3, | ||
"baseSeverity": "MEDIUM", | ||
"attackVector": "NETWORK", | ||
"attackComplexity": "LOW", | ||
"attackRequirements": "NONE", | ||
"privilegesRequired": "LOW", | ||
"userInteraction": "NONE", | ||
"vulnerableSystemConfidentiality": "NONE", | ||
"vulnerableSystemIntegrity": "LOW", | ||
"vulnerableSystemAvailability": "NONE", | ||
"subsequentSystemConfidentiality": "NONE", | ||
"subsequentSystemIntegrity": "NONE", | ||
"subsequentSystemAvailability": "NONE", | ||
"exploitMaturity": "NOT_DEFINED", | ||
"confidentialityRequirements": "NOT_DEFINED", | ||
"integrityRequirements": "NOT_DEFINED", | ||
"availabilityRequirements": "NOT_DEFINED", | ||
"modifiedAttackVector": "NOT_DEFINED", | ||
"modifiedAttackComplexity": "NOT_DEFINED", | ||
"modifiedAttackRequirements": "NOT_DEFINED", | ||
"modifiedPrivilegesRequired": "NOT_DEFINED", | ||
"modifiedUserInteraction": "NOT_DEFINED", | ||
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", | ||
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED", | ||
"modifiedVulnerableSystemAvailability": "NOT_DEFINED", | ||
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", | ||
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED", | ||
"modifiedSubsequentSystemAvailability": "NOT_DEFINED", | ||
"safety": "NOT_DEFINED", | ||
"automatable": "NOT_DEFINED", | ||
"recovery": "NOT_DEFINED", | ||
"valueDensity": "NOT_DEFINED", | ||
"vulnerabilityResponseEffort": "NOT_DEFINED", | ||
"providerUrgency": "NOT_DEFINED" | ||
} | ||
} | ||
] | ||
}, | ||
"weaknesses": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Secondary", | ||
"description": [ | ||
{ | ||
"lang": "en", | ||
"value": "CWE-862" | ||
} | ||
] | ||
} | ||
], | ||
"references": [ | ||
{ | ||
"url": "https://cwe.mitre.org/data/definitions/862.html", | ||
"source": "[email protected]" | ||
} | ||
] | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,100 @@ | ||
{ | ||
"id": "CVE-2024-11737", | ||
"sourceIdentifier": "[email protected]", | ||
"published": "2024-12-11T10:15:06.677", | ||
"lastModified": "2024-12-11T10:15:06.677", | ||
"vulnStatus": "Received", | ||
"cveTags": [], | ||
"descriptions": [ | ||
{ | ||
"lang": "en", | ||
"value": "CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of\nconfidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device." | ||
} | ||
], | ||
"metrics": { | ||
"cvssMetricV40": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Secondary", | ||
"cvssData": { | ||
"version": "4.0", | ||
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", | ||
"baseScore": 9.3, | ||
"baseSeverity": "CRITICAL", | ||
"attackVector": "NETWORK", | ||
"attackComplexity": "LOW", | ||
"attackRequirements": "NONE", | ||
"privilegesRequired": "NONE", | ||
"userInteraction": "NONE", | ||
"vulnerableSystemConfidentiality": "HIGH", | ||
"vulnerableSystemIntegrity": "HIGH", | ||
"vulnerableSystemAvailability": "HIGH", | ||
"subsequentSystemConfidentiality": "NONE", | ||
"subsequentSystemIntegrity": "NONE", | ||
"subsequentSystemAvailability": "NONE", | ||
"exploitMaturity": "NOT_DEFINED", | ||
"confidentialityRequirements": "NOT_DEFINED", | ||
"integrityRequirements": "NOT_DEFINED", | ||
"availabilityRequirements": "NOT_DEFINED", | ||
"modifiedAttackVector": "NOT_DEFINED", | ||
"modifiedAttackComplexity": "NOT_DEFINED", | ||
"modifiedAttackRequirements": "NOT_DEFINED", | ||
"modifiedPrivilegesRequired": "NOT_DEFINED", | ||
"modifiedUserInteraction": "NOT_DEFINED", | ||
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", | ||
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED", | ||
"modifiedVulnerableSystemAvailability": "NOT_DEFINED", | ||
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", | ||
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED", | ||
"modifiedSubsequentSystemAvailability": "NOT_DEFINED", | ||
"safety": "NOT_DEFINED", | ||
"automatable": "NOT_DEFINED", | ||
"recovery": "NOT_DEFINED", | ||
"valueDensity": "NOT_DEFINED", | ||
"vulnerabilityResponseEffort": "NOT_DEFINED", | ||
"providerUrgency": "NOT_DEFINED" | ||
} | ||
} | ||
], | ||
"cvssMetricV31": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Secondary", | ||
"cvssData": { | ||
"version": "3.1", | ||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", | ||
"baseScore": 9.8, | ||
"baseSeverity": "CRITICAL", | ||
"attackVector": "NETWORK", | ||
"attackComplexity": "LOW", | ||
"privilegesRequired": "NONE", | ||
"userInteraction": "NONE", | ||
"scope": "UNCHANGED", | ||
"confidentialityImpact": "HIGH", | ||
"integrityImpact": "HIGH", | ||
"availabilityImpact": "HIGH" | ||
}, | ||
"exploitabilityScore": 3.9, | ||
"impactScore": 5.9 | ||
} | ||
] | ||
}, | ||
"weaknesses": [ | ||
{ | ||
"source": "[email protected]", | ||
"type": "Primary", | ||
"description": [ | ||
{ | ||
"lang": "en", | ||
"value": "CWE-20" | ||
} | ||
] | ||
} | ||
], | ||
"references": [ | ||
{ | ||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-345-03.pdf", | ||
"source": "[email protected]" | ||
} | ||
] | ||
} |
Oops, something went wrong.