PulSync: The Heart Rate Variability as a Unique Fingerprint for the Alignment of Sensor Data Across Multiple Wearable Devices

Download

In this GitHub repository, we present PulSync, a tool for the data-driven offline alignment of sensor data across multiple devices utilizing the unique fingerprint-like character of the heart rate variability (HRV) interval function. The accuracy of the novel method has been evaluated on a dataset from 25 subjects [1] and demonstrated the reliable alignment of independent electrocardiography (ECG) recordings with a mean accuracy of -0.71 ± 3.44 samples, respectively -2.86 ± 11.43 ms at 250 Hz sampling rate. The implemented Python tool is available for download, to support the reproducibility as well as the alignment of datasets from unsynchronized in-the-wild recordings. The Jupyter notebook demonstrates the use of the PulSync Python tool on the example of the ECG recordings and R peak labels from subject 23, exemplarily prepared as a Pickle file.

Citation

"PulSync: The Heart Rate Variability as a Unique Fingerprint for the Alignment of Sensor Data Across Multiple Wearable Devices", Florian Wolling, Kristof Van Laerhoven, Pekka Siirtola, and Juha Röning. In PerHealth 2021: 5th IEEE PerCom Workshop on Pervasive Health Technologies (PerHealth 2021), Virtual Event, IEEE, March 2021.

Disclaimer

You may use the source code of the developed synchronization tool PulSync for scientific, non-commercial purposes, provided that you give credit to the owners when publishing any work based on it. We would also be very interested to hear back from you if you use our tool or alignment method in any way and are happy to answer any questions or address any remarks related to it.

Teaser Video

The 1-minute teaser for the PerHealth'21 workshop can be found on YouTube.

PerHealth'21 Teaser - PulSync: The Heart Rate Variability as a Unique Fingerprint for the Alignment of Sensor Data Across Multiple Wearable Devices

Full Presentation Video

The full 15-minute presentation for the PerHealth'21 workshop can be found on YouTube, as well.

PerHealth'21 Full Presentation - PulSync: The Heart Rate Variability as a Unique Fingerprint for the Alignment of Sensor Data Across Multiple Wearable Devices

Applied Dataset

The PulSync processing pipeline has been evaluated using the dataset 716 of Howell and Porr from the University of Glasgow [1]. It contains ECG measurements from 25 subjects, recorded with two independent, pretended synchronous sensing devices in Einthoven II and resembled V2-V1 lead configurations. The "sitting" subset contains manually annotated peak labels with a precision of ±1 sample. Those were used to generate the heart rate variability (HRV) interval functions that are utilized to align the recordings.

Results

The evaluation of the data-driven alignment method PulSync resulted in a promising accuracy of -0.71 ± 3.44 samples, respectively -2.86 ± 11.43 ms at a sampling rate of 250 Hz and with the HRV interval functions resampled at 25 Hz. The initial misalignment of the original recordings was determined with a mean of 15.328 ± 428.023 samples, 0.061 ± 1.712 s respectively. The smallest initial misalignment was present in the recordings of subject 5 with 0.038 s, while subject 19 showed the largest offset of even 4.969 s.

alignment error ε
subjectoriginal misalignment Δmeanstd
01600.164 ms-3.856 ms±23.287 ms
02-51.084 ms-7.082 ms±23.449 ms
03452.556 ms-3.460 ms±11.195 ms
04-362.652 ms5.360 ms±14.265 ms
0538.488 ms2.487 ms±17.075 ms
06-167.911 ms-7.906 ms±8.902 ms
07-375.427 ms-7.414 ms±7.361 ms
08327.127 ms7.117 ms±13.002 ms
09-3393.174 ms6.939 ms±9.879 ms
10-3492.561 ms-12.445 ms±10.223 ms
11-401.634 ms-1.621 ms±3.728 ms
12-491.203 ms-11.187 ms±5.550 ms
131401.131 ms-2.915 ms±10.560 ms
143215.762 ms3.654 ms±7.893 ms
15-396.886 ms3.127 ms±16.765 ms
16196.308 ms-3.698 ms±14.890 ms
17510.017 ms-10.000 ms±5.586 ms
18-82.679 ms-2.676 ms±5.521 ms
194969.422 ms9.257 ms±6.627 ms
203186.051 ms1.945 ms±8.233 ms
21-60.189 ms-20.188 ms±1.720 ms
22-163.334 ms-3.329 ms±6.952 ms
23-974.843 ms-14.811 ms±6.698 ms
24-1833.231 ms6.830 ms±3.206 ms
25-553.026 ms2.993 ms±8.011 ms