Read/Write data from Allen Bradley Compact/Control Logix PLC's
License
garrosh/pylogix
Folders and files
| Name | Name | Last commit message | Last commit date | |
|---|---|---|---|---|
Repository files navigation
****************************************
USAGE - Python 2.7.11
****************************************
1) from eip import PLC
2) test = PLC()
3) Set the IP Address: test.IPAddress = "192.168.1.10"
4) If your processor is in a slot other than 0, set that: test.ProcessorSlot = 1
5) Do one of the following:
Read a value: value = test.Read("tagname")
ex: value = test.Read("MyTimer.ACC")
print value
Read an array: value = test.Read("tagname", length)
ex: value = test.Read("MyDINT", 10)
print value(3)
Read multiple tags at once: test.MultiRead("tag1", "tag2", "tag3")
ex: values = test.MultiRead("MyDINT", "MyTimer.ACC", "AnotherDINT")
print values
Write a value: test.Write("tagname", value)
ex: test.Write("MyDINT", 1337)
Get the controller scoped tags
ex: tags = test.GetTagList()
(returns a structure of .TagName, .DataType and .Offset)
Get all Ethernet I/P devices on the network test.Discover()
ex: stuff = test.Discover()
print stuff(1).IPAddress # prints the first devices IP Address
So a complete script to read a tag would look like this:
from eip import PLC
test = PLC()
test.IPAddress = "192.168.1.64"
value = test.Read("MyTimer.ACC")
print value
****************************************
NOTES
****************************************
Several things take place when making a connection to a PLC.
1) Standard TCP connection
2) Session Registration, PLC will respond with a Session Handle
3) Forward Open. Using the Session Handle, this establishes
the parameters for connection
4) Command (read/write/etc) and payload
The initial connections (TCP, Session Registration, Forward Open)
only need to be made once, after that, we can exchange data
until the connection is closed or lost.
A number events that take place on the command end, they should
be invisible to the user, but it's good to know (and a reminder for me).
The user can be reading/writing simple tags, UDT's arrays, bits of a word,
bools out of atomic arrays, custom length strings, array reads that
won't fit in a single reply and so on. Each has to be handled in a
different way.
It basically happens like this: Figure out if its a single tag to be
read/written or an array. Open the connection to the PLC (1,2,3 above),
parse the tag name, add the command (read/write), send the data to the PLC,
handle the reply
In order to perform a typical read/write, the data type needs to be known, or
more specifically, the number of bytes the tag is. It would be pretty
annoying for the user to have to specify this each time, so to get around
this, we have the InitialRead function. This is called on any data exchange
where the tag name has never been read/written before. It uses a different
CIP command than a typical read (0x52 vs 0x4C) which will respond with the
data type. This helps us in two ways: First, the user won't need to specify
the data type. Second, we can keep track of this information so the next
time the particular tag is called, we already know it's type so we can just
do the normal read/write (0x4C/0x4D/0x4E).About